Evaluation of Chemcatcher? passive samplers for pesticide monitoring using high-frequency catchment scale data

被引:4
|
作者
Farrow, Luke G. [1 ]
Morton, Phoebe A. [1 ]
Cassidy, Rachel [1 ]
Floyd, Stewart [2 ]
McRoberts, W. Colin [2 ]
Doody, Donnacha G. [1 ]
Jordan, Philip [3 ]
机构
[1] Agrifood & Biosci Inst, Agrienvironm Branch, Belfast, North Ireland
[2] Agrifood & Biosci Inst, Food Res Branch, Belfast, North Ireland
[3] Ulster Univ, Sch Geog & Environm Sci, Coleraine, North Ireland
关键词
Chemcatchers; Passive sampling; High frequency sampling; Acid herbicides; Water quality monitoring; Catchment; -scale; LOADS; EVENT; CALIBRATION; POLLUTANTS; DESIGN; TRENDS; STREAM;
D O I
10.1016/j.jenvman.2022.116292
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Passive samplers (PS) have been proposed as an enhanced water quality monitoring solution in rivers, but their performance against high-frequency data over the longer term has not been widely explored. This study compared the performance of Chemcatcher (R) passive sampling (PS) devices with high-frequency sampling (HFS: 7-hourly to daily) in two dynamic rivers over 16 months. The evaluation was based on the acid herbicides MCPA (2-methyl-4-chlorophenoxyacetic acid), mecoprop-P, fluroxypyr and triclopyr. The impact of river discharge parameters on Chemcatcher (R) device performance was also explored. Mixed effects modelling showed that time -weighted mean concentration (TWMC) and flow-weighted mean concentration (FWMC) values obtained by the HFS approach were both significantly higher (p < 0.001) than TWMC values determined from PS regardless of river or pesticide. Modelling also showed that TWMCPS values were more similar to TWMCHFS than FWMCHFS values. However, further testing revealed that MCPA TWMC values from HFS and PS were not significantly different (p > 0.05). There was little indication that river flow parameters altered PS performance-some minor effects were not significant or consistent. Despite this, the PS recovery of very low concentrations indicated that Chemcatcher (R) devices may be used to evaluate the presence/absence and magnitude of acid herbicides in hy-drologically dynamic rivers in synoptic type surveys where space and time coverage is required. However, a period of calibration of the devices in each river would be necessary if they were intended to provide a quan-titative review of pesticide concentration as compared with HFS approaches.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Evaluation of the Chemcatcher and DGT passive samplers for monitoring metals with highly fluctuating water concentrations
    Allan, Ian J.
    Knutsson, Jesper
    Guigues, Nathalie
    Mills, Graham A.
    Fouillac, Anne-Marie
    Greenwood, Richard
    JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (07): : 672 - 681
  • [2] Pesticides monitoring in surface water of a subsistence agricultural catchment in Uganda using passive samplers
    Oltramare, Christelle
    Weiss, Frederik T.
    Staudacher, Philipp
    Kibirango, Oscar
    Atuhaire, Aggrey
    Stamm, Christian
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (04) : 10312 - 10328
  • [3] Pesticides monitoring in surface water of a subsistence agricultural catchment in Uganda using passive samplers
    Christelle Oltramare
    Frederik T. Weiss
    Philipp Staudacher
    Oscar Kibirango
    Aggrey Atuhaire
    Christian Stamm
    Environmental Science and Pollution Research, 2023, 30 : 10312 - 10328
  • [4] High Expectations and Open Questions: Using High-Frequency Proxy Data to Calibrate a Catchment-Scale Phosphorus Model
    Lannergard, Emma E.
    Sandstrom, Sara
    Nilsson, Elin Widen
    Lewan, Elisabet
    Futter, Martyn N.
    ACS ES&T WATER, 2024, 4 (05): : 2135 - 2143
  • [5] Continuous high-frequency pesticide monitoring to observe the unexpected and the overlooked
    la Cecilia, D.
    Dax, A.
    Ehmann, H.
    Koster, M.
    Singer, H.
    Stamm, C.
    WATER RESEARCH X, 2021, 13
  • [6] The effect of sampling frequency and strategy on water quality modelling driven by high-frequency monitoring data in a boreal catchment
    Piniewski, Mikolaj
    Marcinkowski, Pawel
    Koskiaho, Jari
    Tattari, Sirkka
    JOURNAL OF HYDROLOGY, 2019, 579
  • [7] AN EVALUATION OF SEISMIC DECOUPLING AND UNDERGROUND NUCLEAR TEST MONITORING USING HIGH-FREQUENCY SEISMIC DATA
    EVERNDEN, JF
    ARCHAMBEAU, CB
    CRANSWICK, E
    REVIEWS OF GEOPHYSICS, 1986, 24 (02) : 143 - 215
  • [8] SPATIAL INTERPOLATION OF HIGH-FREQUENCY MONITORING DATA
    Stein, Michael L.
    ANNALS OF APPLIED STATISTICS, 2009, 3 (01): : 272 - 291
  • [9] High Frequency Measurement of Metals: Steps Towards the Acceptance of Passive Samplers for Regulatory Monitoring
    Krikech, Imad
    Menchaca, Iratxe
    Belzunce, Maria Jesus
    Ezziyyani, Mohammed
    ADVANCED INTELLIGENT SYSTEMS FOR SUSTAINABLE DEVELOPMENT (AI2SD'2020), VOL 2, 2022, 1418 : 1194 - 1203
  • [10] Hydrogen sulfide measurements in air by passive/diffusive samplers and high-frequency analyzer: A critical comparison
    Venturi, S.
    Cabassi, J.
    Tassi, F.
    Capecchiacci, F.
    Vaselli, O.
    Bellomo, S.
    Calabrese, S.
    D'Alessandro, W.
    APPLIED GEOCHEMISTRY, 2016, 72 : 51 - 58