Dosimetry for neutrons from 0.25 to 15 MeV by the measurement of linear energy transfer distributions for secondary charged particles in CR-39 plastic

被引:14
|
作者
Tawara, Hiroko [1 ]
Eda, Kazuyoshi [1 ]
Sanami, Toshiya [1 ]
Sasaki, Shinichi [1 ]
Takahashi, Kazutoshi [1 ]
Sonkawade, Rajendra [2 ]
Nagamatsu, Aiko [3 ]
Kitajo, Keiichi [4 ]
Kumagai, Hidenori [4 ]
Doke, Tadayoshi [5 ]
机构
[1] High Energy Accelerator Res Org, Radiat Sci Ctr, Tsukuba, Ibaraki 3050801, Japan
[2] Inter Univ Accelerator Ctr, New Delhi 110067, India
[3] Japan Aerosp Explorat Agcy, Space Environm Utilizat Ctr, Tsukuba, Ibaraki 3058505, Japan
[4] Adv Engn Serv Co Ltd, Space Stn Engn Dept, Tsukuba, Ibaraki 3050032, Japan
[5] Waseda Univ, Adv Res Inst Sci & Engn, Shinjuku Ku, Tokyo 1620044, Japan
关键词
LET distribution; fast neutron dosimetry; CR-39; secondary charged particles;
D O I
10.1143/JJAP.47.1726
中图分类号
O59 [应用物理学];
学科分类号
摘要
In the radiation fields of high energy accelerator facilities, high-altitude aircraft and space flights, high-energy neutron dosimetry of similar to 20 MeV or more is a significant issue for radiological protection. We studied the feasibility of experimental measurements of linear energy transfer (LET) distributions for secondary charged particles induced by fast neutrons using CR-39 plastic nuclear track detectors. In order to investigate a method of analyzing the CR-39 detectors that is appropriate for fast neutron dosimetry, two-layer CR-39 stacks were exposed to monochromatic neutrons (0.25, 0.55, 5, and 15 MeV) at the Fast Neutron Laboratory of Tohoku University in Japan. We also conducted Monte Carlo calculations to estimate the detection efficiency of the CR-39 detector for recoil protons. The CR-39 detectors treated by single-step chemical etching were used to obtain LET distributions for LET > 10 keV/mu m-water. The results indicated that measurements of short-range particles are very important for obtaining the correct LET distributions. Using the measured LET distributions, we calculated neutron sensitivities, absorbed doses and dose equivalents based on the ICRP 60 Q-L relation and averaged quality factors. The dose equivalents were compared with the neutron fluence-to-dose equivalent conversion factors given by ICRP 74 and the averaged quality factors were compared with weighting factors given by ICRP 60 and ICRP 92.
引用
收藏
页码:1726 / 1734
页数:9
相关论文
共 18 条
  • [1] Linear energy transfer spectra of secondary particles in CR-39 track etch detectors
    Spurny, F
    Bednar, J
    Johansson, L
    Satherberg, A
    RADIATION MEASUREMENTS, 1996, 26 (05) : 645 - 649
  • [2] Linear energy transfer spectra of secondary particles in CR-39 track etch detectors
    Nuclear Physics Inst of the Acad of, Science, Praha, Czech Republic
    Radiat Meas, 5 (645-649):
  • [3] Activation energy of etching for CR-39 as a function of linear energy transfer of the incident particles
    Awad, EM
    El-Samman, HM
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 109 - 114
  • [4] Detection threshold control of CR-39 plastic nuclear track detectors for the selective measurement of high LET secondary charged particles
    Kodaira, S.
    Yasuda, N.
    Kawashima, H.
    Kurano, M.
    Naka, S.
    Ota, S.
    Ideguchi, Y.
    Hasebe, N.
    Ogura, K.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1782 - 1785
  • [5] Comparison of linear energy transfer measurement for therapeutic carbon beam using CR-39 and TLD
    Yuan, Zhou
    Zhuo, Weihai
    Yang, Shiyan
    Li, Zhiling
    Zhao, Jingfang
    Chen, Bo
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [6] Calculation of energy distributions of charged particles produced by neutrons from 0.14 to 65 MeV in tissue substitutes
    Tsuda, S.
    Nakane, Y.
    Yamaguchi, Y.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 174 - 177
  • [8] Measurements of dose-averaged linear energy transfer distributions in water using CR-39 plastic nuclear track detector for therapeutic carbon ion beams
    Kohno, R
    Yasuda, N
    Takeshi, H
    Kase, Y
    Ochiai, K
    Komori, M
    Matsufuji, N
    Kanai, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (12): : 8722 - 8726
  • [9] Measurement of LET (linear energy transfer) spectra using CR-39 at different depths of water irradiated by 171 MeV protons: A comparison with Monte Carlo simulation
    Sahoo, G. S.
    Tripathy, S. P.
    Molokanov, A. G.
    Aleynikov, V. E.
    Sharma, S. D.
    Bandyopadhyay, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 818 : 14 - 19
  • [10] Measurement of a linear energy transfer distribution with antioxidant doped CR-39 correcting for the dip angle dependence of track formation sensitivity
    Tawara, Hiroko
    Masukawa, Mitsuyo
    Nagamatsu, Aiko
    Kitajo, Keiichi
    Kumagai, Hidenori
    Yasuda, Nakahiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (09) : 7324 - 7327