Closed-Loop Analytic Filtering Scheme of Capacitor Voltage Ripple in Multilevel Cascaded H-Bridge Converters

被引:19
|
作者
Rodriguez, Ezequiel [1 ]
Farivar, Glen G. [2 ]
Beniwal, Neha [2 ,3 ]
Townsend, Christopher D. [4 ]
Tafti, Hossein Dehghani [1 ]
Vazquez, Sergio [5 ]
Pou, Josep [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Energy Res Inst, Singapore 639798, Singapore
[3] Nanyang Technol Univ, Interdisciplinary Grad Sch, Singapore 639798, Singapore
[4] Univ Western Australia, Dept Elect Elect & Comp Engn, Crawley, WA 6009, Australia
[5] Univ Seville, Elect Dept, Seville 41092, Spain
关键词
Capacitance estimation; capacitor voltage filtering; cascaded H-bridge (CHB); multilevel converter; static compensator (STATCOM); POWER CONVERTERS; GRID SYNCHRONIZATION; PERFORMANCE; INVERTER; STATCOM;
D O I
10.1109/TPEL.2020.2966305
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes a closed-loop analytic filtering scheme for the low-frequency capacitor voltage ripple in cascaded H-bridge converters. Although this technique can be applied to a number of cascaded converter applications, this article focuses particularly on the low-capacitance cascaded H-bridge static compensator. Filtering of capacitor voltage signals is particularly important in this application, due to the presence of large low-frequency harmonic voltage ripple. The main novelty of the proposed algorithm in this article is the estimation of the capacitance value of each H-bridge. The closed-loop capacitance estimation method reduces steady-state error in estimated voltage ripple magnitude and phase, which is otherwise present in the available open-loop filters in the literature. Furthermore, fast dynamic response is achieved compared to filtering schemes based on low-pass and bandstop filters. Therefore, the proposed solution optimizes the tradeoff between filtering accuracy and transient response. It also mitigates parametric uncertainties, time delays, and harmonic contamination in the outer voltage control loop. Furthermore, the estimated capacitance is also useful to track the state of health of the dc-link capacitors. Experimental results on a seven-level 1-kVA cascaded H-bridge prototype are presented to demonstrate the comparative performance of the proposed filtering scheme and traditional approaches.
引用
收藏
页码:8819 / 8832
页数:14
相关论文
共 50 条
  • [1] Hybrid Control of Cascaded H-Bridge Multilevel Converters for Multiple Capacitor Voltage Balancing
    Aldunate, Jose Santiago
    Pereda, Javier
    [J]. PROCEEDINGS 2016 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2016, : 311 - 316
  • [2] Constraints for balancing capacitor voltage of cascaded H-bridge converters
    Liu Q.
    Wu M.
    Wu L.
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2016, 40 (15): : 113 - 119
  • [3] The Capacitor Voltage Balancing of Cascaded H-bridge Multilevel Inverter
    Nos, Oleg V.
    Kharitonov, Sergey A.
    Abramushkina, Ekaterina E.
    Brovanov, Sergey V.
    Smirnov, Pavel N.
    [J]. 2019 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS (ICM), 2019, : 327 - 331
  • [4] Performance Improvement of DC Capacitor Voltage Balancing Control for Cascaded H-Bridge Multilevel Converters
    Liu, Bi
    Song, Wensheng
    Li, Yunwei
    Zhan, Bo
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (03) : 3354 - 3366
  • [5] Investigation on Capacitor Voltage Regulation in Cascaded H-Bridge Multilevel Converters With Fundamental Frequency Switching
    Sepahvand, Hossein
    Liao, Jingsheng
    Ferdowsi, Mehdi
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (11) : 5102 - 5111
  • [6] A Fast Filtering Scheme for Capacitor Voltages of a Cascaded H-Bridge Multilevel Converter Based STATCOM
    Farivar, Ghias
    Agelidis, Vassilios G.
    Hredzak, Branislav
    [J]. 2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,
  • [7] Non-Uniform Capacitor Voltage Ripple in a Cascaded H-bridge StatCom
    Townsend, C. D.
    Vodden, J.
    Watson, A. J.
    Summers, T. J.
    Betz, R. E.
    Clare, J. C.
    [J]. 2012 22ND AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC): GREEN SMART GRID SYSTEMS, 2012,
  • [8] Optimization of Switching Losses and Capacitor Voltage Ripple Using Model Predictive Control of a Cascaded H-Bridge Multilevel StatCom
    Townsend, Christopher D.
    Summers, Terrence J.
    Vodden, John
    Watson, Alan J.
    Betz, Robert E.
    Clare, Jon C.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (07) : 3077 - 3087
  • [9] Feasibility of Capacitor Voltage Regulation and Output Voltage Harmonic Minimization in Cascaded H-Bridge Converters
    Sepahvand, Hossein
    Khazarei, Mostafa
    Ferdowsi, Mehdi
    Corzine, Keith
    [J]. 2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, : 452 - 457
  • [10] DC bus ripple minimization in cascaded H-bridge multilevel converters under staircase modulation
    Fukuta, Y
    Venkataramanan, G
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, : 1988 - 1993