摘要
Background Automated breast ultrasound (ABUS) is one of the first ultrasound devices which enables the de-coupling of image acquisition and interpretation. Another feature of ABUS is the coronal view, utilizing three-dimensional volume data reconstructed from two-dimensional transverse images acquired automatically. Purpose To assess the diagnostic performance of coronal view interpretation by comparing it with that of the transverse view. Material and Methods This was a retrospective, multi-case, observer study using a cancer-enriched dataset of ABUS images at a single institution with approval by an Institutional Review Board. The 100 scan datasets selected between October 2014 and January 2017 included 70 non-cancer cases and 30 malignancies. In the present observer study, two experienced physicians provided their confidence levels regarding the malignancy of each of the 100 scan datasets independently. The reading times for interpretation of coronal and transverse views were recorded. Results Area under the receiver operating characteristic curves for two observers with the transverse view (0.856) was improved by use of the coronal view (0.917, P = 0.036). The average reading times were 140.4 s with the coronal view and 148.5 s with the transverse view per scan dataset (P = 0.246). Conclusion It is conceivable that the accurate use of the coronal view will lead to improvement in diagnostic performance in breast cancer screening, although this needs to be confirmed with a larger prospective study.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [1] Three-dimensional extended field-of-view ultrasound
    Poon, TC
    Rohling, RN
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (03): : 357 - 369
  • [2] Potential Usefulness a Coronal View using an Automated Breast Ultrasound System in Detecting Breast Lesions
    Suzuki, Megumi
    Nakayama, Ryohei
    Namba, Kiyoshi
    Kawami, Hiroyuki
    Nara, Mayumi
    Nakamura, Seigo
    EUROPEAN JOURNAL OF BREAST HEALTH, 2024, 20 (01) : 57 - 63
  • [3] Three-dimensional ultrasound evaluation of the fetal brain: the three horn view
    Timor-Tritsch, IE
    Monteagudo, A
    Mayberry, P
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (04) : 302 - 306
  • [4] View planning for automated three-dimensional object reconstruction and inspection
    Scott, WR
    Roth, G
    Rivest, JF
    ACM COMPUTING SURVEYS, 2003, 35 (01) : 64 - 96
  • [5] Assessing Diagnostic Performance Using the Transverse Plane Plus Coronal Plane Compared With the Transverse Plane Alone in Screening Automated Breast Ultrasound
    Wang, Yin
    Yue, Jinzhuo
    Xing, Yangfeng
    Ju, Yan
    Gao, Xican
    Shu, Rui
    Wang, Zhenfang
    Liu, Bo
    Xiao, Yao
    Zhang, Ge
    Li, Hui
    Wang, Tian
    Guan, Xiangping
    Song, Zhangjun
    Song, Hongping
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (06) : 1013 - 1024
  • [6] A Three-Dimensional View of Personality
    Mayer, John D.
    Lang, Jenny L.
    PSYCHOLOGICAL INQUIRY, 2011, 22 (01) : 36 - 39
  • [7] Extended field-of-view and three-dimensional ultrasound imaging of silicone breast implant lesions
    Papadia, A.
    Menada, M. V.
    Ragni, N.
    Brusaca, B.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (03) : 360 - 361
  • [8] The value of coronal view as a stand-alone assessment in women undergoing automated breast ultrasound
    Simone Schiaffino
    Licia Gristina
    Simona Tosto
    Elena Massone
    Sara De Giorgis
    Alessandro Garlaschi
    Alberto Tagliafico
    Massimo Calabrese
    La radiologia medica, 2021, 126 : 206 - 213
  • [9] The value of coronal view as a stand-alone assessment in women undergoing automated breast ultrasound
    Schiaffino, Simone
    Gristina, Licia
    Tosto, Simona
    Massone, Elena
    De Giorgis, Sara
    Garlaschi, Alessandro
    Tagliafico, Alberto
    Calabrese, Massimo
    RADIOLOGIA MEDICA, 2021, 126 (02): : 206 - 213
  • [10] Automated quality assessment in three-dimensional breast ultrasound images
    Schwaab, Julia
    Diez, Yago
    Oliver, Arnau
    Marti, Robert
    van Zelst, Jan
    Gubern-Merida, Albert
    Mourri, Ahmed Bensouda
    Gregori, Johannes
    Guenther, Matthias
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (02)