Stormwater monitoring using on-line UV-Vis spectroscopy

被引:1
|
作者
Huang, Jianyin [1 ,2 ]
Chow, Christopher W. K. [1 ,2 ]
Shi, Zhining [3 ]
Fabris, Rolando [4 ]
Mussared, Amanda [4 ]
Hallas, Gary [4 ]
Monis, Paul [1 ,4 ]
Jin, Bo [3 ]
Saint, Christopher P. [1 ,2 ]
机构
[1] Univ South Australia, UniSA STEM, Scarce Resources & Circular Econ ScaRCE, Adelaide, SA 5095, Australia
[2] Univ South Australia, Future Ind Inst, Adelaide, SA 5095, Australia
[3] Univ Adelaide, Sch Chem Engn, Adelaide, SA 5005, Australia
[4] Australian Water Qual Ctr, 250 Victoria Sq, Adelaide, SA 5000, Australia
关键词
Stormwater; Real-time monitoring; UV-vis spectrophotometer; Surrogate parameter; Nitrate; E; coli; ESCHERICHIA-COLI; URBAN STORMWATER; WATER-POLLUTION; LAND-USE; RUNOFF; TSS; COD; SPECTROPHOTOMETRY; CALIBRATION; ENVIRONMENT;
D O I
10.1007/s11356-021-17056-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Stormwater runoff contains a myriad of pollutants, including faecal microbes, and can pose a threat to urban water supplies, impacting both economic development and public health. Therefore, it is a necessity to implement a real-time hazard detection system that can collect a substantial amount of data, assisting water authorities to develop preventive strategies to ensure the control of hazards entering drinking water sources. An on-line UV-Vis spectrophotometer was applied in the field to collect real-time continuous data for various water quality parameters (nitrate, DOC, turbidity and total suspended solids) during three storm events in Mannum, Adelaide, Australia. This study demonstrated that the trends for on-line and comparative laboratory-analysed samples were complimentary through the events. Nitrate and DOC showed a negative correlation with water level, while turbidity and total suspended solids indicated a positive correlation with water level during the high rainfall intensity. The correlations among nitrate, DOC, turbidity, total suspended solids and water level are the opposite during low rainfall intensity. Nitrate, one of the main pollutants in stormwater, was investigated and used as a surrogate parameter for microbial detection. However, the microbiological data (Escherichia coli) from captured storm events showed poor correlations to nitrate and other typical on-line parameters in this study. This is possibly explained by the nature of the stormwater catchment outside of rain events, where the sources of bacteria and nutrients may be physically separated until mixed during surface runoff as a result of rainfall. In addition, the poor correlations among the microbiological data and on-line parameters could be due to the different sources of bacteria and nutrients that were transported to the stormwater drain where sampling and measurement were conducted.
引用
收藏
页码:19530 / 19539
页数:10
相关论文
共 50 条
  • [1] Stormwater monitoring using on-line UV-Vis spectroscopy
    Jianyin Huang
    Christopher W. K. Chow
    Zhining Shi
    Rolando Fabris
    Amanda Mussared
    Gary Hallas
    Paul Monis
    Bo Jin
    Christopher P. Saint
    [J]. Environmental Science and Pollution Research, 2022, 29 : 19530 - 19539
  • [2] UV-vis spectroscopy for on-line monitoring of Au nanoparticles size during growth
    Salvati, R
    Longo, A
    Carotenuto, G
    De Nicola, S
    Pepe, GP
    Nicolais, L
    Barone, A
    [J]. APPLIED SURFACE SCIENCE, 2005, 248 (1-4) : 28 - 31
  • [3] Process monitoring using UV-VIS spectroscopy
    Bart, JCJ
    [J]. ANTEC 2000: SOCIETY OF PLASTICS ENGINEERS TECHNICAL PAPERS, CONFERENCE PROCEEDINGS, VOLS I-III, 2000, : 3741 - 3745
  • [4] On-line monitoring of volume expansion in gas-antisolvent processes by UV-vis spectroscopy
    Elvassore, N
    Bertucco, A
    Di Noto, V
    [J]. JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2002, 47 (02): : 223 - 227
  • [5] On-Line Coupling of Microcolumn Electrophoresis and UV-Vis Spectrophotometry
    Li Lian
    He You-zhao
    Gan Wu-er
    Wang Xiao-kui
    Xie Hai-yang
    Gao Yong
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (03) : 762 - 766
  • [6] On-line concentration measurement for anti-solvent crystallization of β-artemether using UV-vis fiber spectroscopy
    Zhang, Yang
    Jiang, Yanbin
    Zhang, Duanke
    Li, Kaixia
    Qian, Yu
    [J]. JOURNAL OF CRYSTAL GROWTH, 2011, 314 (01) : 185 - 189
  • [7] UV-Vis spectroscopy
    Picollo, Marcello
    Aceto, Maurizio
    Vitorino, Tatiana
    [J]. PHYSICAL SCIENCES REVIEWS, 2019, 4 (04)
  • [8] On-line monitoring in photocatalytic degradation of 4-chlorophenol by using cyclic voltammetry and UV-Vis spectrometry
    He, F
    Shen, WR
    Zhao, WK
    Fang, C
    Fang, YL
    [J]. CHINESE JOURNAL OF CATALYSIS, 2001, 22 (02) : 168 - 170
  • [9] UV-Vis spectroscopy with chemometric data treatment: an option for on-line control in nuclear industry
    Kirsanov, Dmitry
    Rudnitskaya, Alisa
    Legin, Andrey
    Babain, Vasily
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 312 (03) : 461 - 470
  • [10] The Use of UV-Vis Spectroscopy in Bioprocess and Fermentation Monitoring
    Roberts, Jessica
    Power, Aoife
    Chapman, James
    Chandra, Shaneel
    Cozzolino, Daniel
    [J]. FERMENTATION-BASEL, 2018, 4 (01):