Machine learning-based event recognition in SiFi Compton camera imaging for proton therapy monitoring

被引:11
|
作者
Kazemi Kozani, Majid [1 ]
Magiera, Andrzej [1 ]
机构
[1] Jagiellonian Univ, Marian Smoluchowski Inst Phys, Krakow, Poland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 15期
关键词
proton therapy; prompt gamma; Compton camera; machine learning; image reconstruction; PROMPT GAMMA-RAYS; BEAM RANGE VERIFICATION; BOOSTED DECISION TREES; RECONSTRUCTION; FEASIBILITY; EMISSION; DETECTOR; PATIENT; SYSTEM;
D O I
10.1088/1361-6560/ac71f2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Online monitoring of dose distribution in proton therapy is currently being investigated with the detection of prompt gamma (PG) radiation emitted from a patient during irradiation. The SiPM and scintillation Fiber based Compton Camera (SiFi-CC) setup is being developed for this aim. Approach. A machine learning approach to recognize Compton events is proposed, reconstructing the PG emission profile during proton therapy. The proposed method was verified on pseudo-data generated by a Geant4 simulation for a single proton beam impinging on a polymethyl methacrylate (PMMA) phantom. Three different models including the boosted decision tree (BDT), multilayer perception (MLP) neural network, and k-nearest neighbour (k-NN) were trained using 10-fold cross-validation and then their performances were assessed using the receiver operating characteristic (ROI) curves. Subsequently, after event selection by the most robust model, a software based on the List-Mode Maximum Likelihood Estimation Maximization (LM-MLEM) algorithm was applied for the reconstruction of the PG emission distribution profile. Main results. It was demonstrated that the BDT model excels in signal/background separation compared to the other two. Furthermore, the reconstructed PG vertex distribution after event selection showed a significant improvement in distal falloff position determination. Significance. A highly satisfactory agreement between the reconstructed distal edge position and that of the simulated Compton events was achieved. It was also shown that a position resolution of 3.5 mm full width at half maximum (FWHM) in distal edge position determination is feasible with the proposed setup.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] The SiFi-CC project - Feasibility study of a scintillation-fiber-based Compton camera for proton therapy monitoring
    Kasper, Jonas
    Rusiecka, Katarzyna
    Hetzel, Ronja
    Kozani, Majid Kazemi
    Lalik, Rafal
    Magiera, Andrzej
    Stahl, Achim
    Wronska, Aleksandra
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 317 - 325
  • [2] Noise evaluation of Compton camera imaging for proton therapy
    Ortega, P. G.
    Torres-Espallardo, I.
    Cerutti, F.
    Ferrari, A.
    Gillam, J. E.
    Lacasta, C.
    Llosa, G.
    Oliver, J. F.
    Sala, P. R.
    Solevi, P.
    Rafecas, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05): : 1845 - 1863
  • [3] Machine learning-based event generator for electron-proton scattering
    Alanazi, Y.
    Ambrozewicz, P.
    Battaglieri, M.
    Blin, A. N. Hiller
    Kuchera, M. P.
    Li, Y.
    Liu, T.
    McClellan, R. E.
    Melnitchouk, W.
    Pritchard, E.
    Robertson, M.
    Sato, N.
    Strauss, R.
    Velasco, L.
    PHYSICAL REVIEW D, 2022, 106 (09)
  • [4] Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy
    Gueth, P.
    Dauvergne, D.
    Freud, N.
    Letang, J. M.
    Ray, C.
    Testa, E.
    Sarrut, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13): : 4563 - 4577
  • [5] Influence of the background in Compton camera images for proton therapy treatment monitoring
    Borja-Lloret, M.
    Barrientos, L.
    Bernabeu, J.
    Lacasta, C.
    Munoz, E.
    Ros, A.
    Roser, J.
    Viegas, R.
    Llosa, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14):
  • [6] An Improved Method for Event Selection in Compton Camera Imaging for Particle Therapy
    Mackin, D.
    Beddar, S.
    Polf, J.
    Peterson, S.
    Draeger, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3454 - 3454
  • [7] Evaluation of a multistage CdZnTe Compton camera for prompt γ imaging for proton therapy
    McCleskey, M.
    Kaye, W.
    Mackin, D. S.
    Beddar, S.
    He, Z.
    Polf, J. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 785 : 163 - 169
  • [8] Simulation study of Compton camera imaging for human head phantom proton therapy
    Yao, Zhiyang
    Chen, Zhiqiang
    Xiao, Yongshun
    SECOND SYMPOSIUM ON NOVEL TECHNOLOGY OF X-RAY IMAGING, 2019, 11068
  • [9] Clinical applicability of the Compton camera for Prompt γ-ray Imaging during proton therapy
    Rohling, H.
    Priegnitz, M.
    Schoene, S.
    Schumann, A.
    Enghardt, W.
    Golnik, C.
    Hueso-Gonzalez, F.
    Kormoll, T.
    Pausch, G.
    Petzoldt, J.
    Roemer, K.
    Fiedler, F.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S90 - S91
  • [10] Evaluating a Stochastic Reconstruction Algorithm for Compton Camera Based Prompt Gamma Imaging during Proton Therapy
    Mackin, D.
    Polf, J.
    Peterson, S.
    Gillin, M.
    Beddar, S.
    MEDICAL PHYSICS, 2011, 38 (06)