Investigation of essential element distribution in the equine metacarpophalangeal joint using a synchrotron radiation micro x-ray fluorescence technique

被引:0
|
作者
Kaabar, Wejdan [1 ]
Gundogdu, O. [1 ]
Tzaphlidou, M. [2 ]
Janousch, M. [3 ]
Attenburrow, D. [1 ]
Bradley, D. A. [1 ]
机构
[1] Univ Surrey, Dept Phys, Surrey GU2 7XH, England
[2] Univ Loannina, Sch Med, Lab Med Phys, Loannina 45110, Greece
[3] LUCIA, Paul Scherrer Inst, Villigen, Switzerland
来源
关键词
SR-mu XRF; osteoarthritis; equine metacarpophalangeal joint; essential element profiles;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
In articular cartilage, Ca, P, K and S are among some of the well known co-factors of the metalloproteinases enzymatic family, the latter playing a pivotal role in the growth and degeneration of the collagenous bone-cartilage interface of articulating joints. Current study forms part of a larger investigation concerning the distribution of these and other key elements in such media. For the purpose of evaluating these low atomic number elements (Z <= 20), use was made of the capabilities of the LUCIA Station, located at the synchrotron facility of the Paul Scherrer Institute (PSI). Using an incident radiation energy of 4.06 keV, a synchrotron radiation micro x-ray fluorescence (SR-mu XRF) technique was applied in examining the distribution of the essential elements Ca, P, K and S in the bone-cartilage interface of both healthy and diseased (osteoarthritic) areas of an equine metacarpophalangeal joint. The SR-mu XRF mappings and line profile patterns have revealed remarkable changes in both the pattern and absolute distributions of these elements, agreeing with the findings of others. The elemental presence shown in the individual area scans encompassing the lesion each reflect the visibly abraded outer surface of the cartilage and change in shape of the bone surface. One of the area scans for the bone-cartilage interface shows a marked change in both the pattern and absolute elemental presence for all three elements compared to that observed at two other scan sites. The observation of change in bone cartilage composition around the surface of the articulating joint is thought to be novel, the variation being almost certainly due to the differing weight-bearing role of the subchondral bone at each location.
引用
收藏
页码:18 / +
页数:2
相关论文
共 50 条
  • [1] Preliminary investigation of trace element in Pterygium using Synchrotron radiation micro-beam X-ray fluorescence analysis (μ-XRF)
    Xie, Q.
    Peng, L.
    Cai, F.
    Li, Ai G.
    Yang, K.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8
  • [2] Study of the distribution of actinides in human tissues using synchrotron radiation micro X-ray fluorescence spectrometry
    Eva Vergucht
    Björn De Samber
    Andrei Izmer
    Bart Vekemans
    Karen Appel
    Sergei Tolmachev
    Laszlo Vincze
    Frank Vanhaecke
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 1559 - 1566
  • [3] Study of the distribution of actinides in human tissues using synchrotron radiation micro X-ray fluorescence spectrometry
    Vergucht, Eva
    De Samber, Bjoern
    Izmer, Andrei
    Vekemans, Bart
    Appel, Karen
    Tolmachev, Sergei
    Vincze, Laszlo
    Vanhaecke, Frank
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (06) : 1559 - 1566
  • [4] TRACE ELEMENT QUANTIFICATION USING SYNCHROTRON RADIATION X-RAY FLUORESCENCE ANALYSIS
    Hayakawa, Shinjiro
    Iida, Atsuo
    Gohshi, Yohichi
    [J]. ANALYTICAL SCIENCES, 1991, 7 : 509 - 512
  • [5] Element distribution in the brain sections of rats measured by synchrotron radiation X-ray fluorescence
    Liu, NQ
    Zhang, E
    Wang, XE
    Zhang, ZY
    Chai, ZF
    Huang, YY
    He, W
    Zhao, XQ
    Zuo, AJ
    Yang, R
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (02) : 255 - 260
  • [6] X-ray fluorescence measurements of arsenic micro-distribution in human nail clippings using synchrotron radiation
    Gherase, Mihai R.
    Desouza, Elstan D.
    Farquharson, Michael J.
    McNeill, Fiona E.
    Kim, Chang-Yong
    Fleming, David E. B.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2013, 34 (09) : 1163 - 1177
  • [7] Element distribution in the brain of rats exposed to lanthanum measured by synchrotron radiation X-ray fluorescence
    L. X. Feng
    H. Q. Xiao
    X. He
    Z. J. Li
    F. L. Li
    N. Q. Liu
    Z. F. Chai
    Y. L. Zhao
    Y. Y. Huang
    W. He
    Z. Y. Zhang
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2007, 272 : 333 - 337
  • [8] Element distribution in the brain of rats exposed to lanthanum measured by synchrotron radiation X-ray fluorescence
    Feng, L. X.
    Xiao, H. Q.
    He, X.
    Li, Z. J.
    Li, F. L.
    Liu, N. Q.
    Chai, Z. F.
    Zhao, Y. L.
    Huang, Y. Y.
    He, W.
    Zhang, Z. Y.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 272 (02) : 333 - 337
  • [9] X-RAY OPTICS FOR SYNCHROTRON-RADIATION-INDUCED X-RAY MICRO FLUORESCENCE AT THE EUROPEAN SYNCHROTRON-RADIATION FACILITY, GRENOBLE
    VINCZE, L
    JANSSENS, K
    ADAMS, F
    [J]. INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 613 - 616
  • [10] Bivalve Characterization Using Synchrotron Micro X-Ray Fluorescence
    Jones, K. W.
    Bronson, S.
    Brink, P.
    Gordon, C.
    Mosher-Smith, K.
    Brown, M.
    Chaudhry, S.
    Rizzo, A.
    Sigismondi, R.
    Whitehurst, M.
    Lukaszewski, A.
    Kranz, D.
    Bland, K.
    Gordan, D.
    Lobel, J.
    Sullivan, J.
    Metzger, M.
    O'Shea, C.
    Harris, C.
    Arezzo, R.
    Kambhampati, M. S.
    [J]. ACTA PHYSICA POLONICA A, 2009, 115 (02) : 477 - 481