GAIT ANALYSIS USING IMU SENSOR

被引:26
|
作者
Gujarathi, Trupti [1 ]
Bhole, Kalyani [1 ]
机构
[1] Coll Engn, Dept Instrumentat & Control, Pune, Maharashtra, India
关键词
Gait cycle analysis; Inertial Measurement Unit(IMU) sensor; Gyro-sensor MPU6050; Bluetooth module; Gait parameters; EXTRACTION;
D O I
10.1109/icccnt45670.2019.8944545
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Inertial Measurement Unit (IMU) based systems that employ gyroscopes has a growing interest in gait analysis. We described the IMU-based gait analysis method that uses angles obtained from an accelerometer and gyroscope sensor within MPU6050 to identify phases of each gait cycle during walking. The gait analysis algorithm is composed of Heel strike and Toe off factors detection observed by means of detection of initial contact(IC) and terminal contact(TC) so that gait parameters are calculated from those gait details. Most of the present gait phase detection strategies use multiple sensor modules connected to every segment of lower body. We have used two MPU6050 sensors placed on a shank of both legs to collect gait signals. For experimental purpose, each participant was asked to walk for a distance of 40 meters for the straight corridor at a normal speed. These gait signal data measured by using Arduino uno micro-controller is then transmitted to an android app 'Blueterm' wirelessly via the HC-05 Bluetooth module. Collected data by the app is stored as a text file in a device containing app. This database is further processed to an algorithm that has been developed using MATLAB to extract a period of events that happened during walking such as stride time, stance time, step time, cadence, etc. The results are useful in identifying the biomechanical stability of patients post surgery. Basically, this paper presents a wearable IMU sensor-based system and its associated gait analysis algorithm to obtain quantitative measurements of the individual's gait parameters to monitor patient progress in orthopedics and rehabilitation.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Gait analysis by IMU sensor in myotonic dystrophy type 1
    Tufano, L.
    Bianchini, E.
    Bucci, E.
    Antonini, G.
    Garibaldi, M.
    NEUROMUSCULAR DISORDERS, 2024, 43
  • [2] Accurate Estimation of Gait Altitude Using One Wearable IMU Sensor
    Liang, Jiaqi
    Duan, Hongjun
    Li, Jinli
    Sun, Hui
    Sha, Xiaopeng
    Zhao, Yuliang
    Liu, Lianqing
    2018 IEEE 1ST INTERNATIONAL CONFERENCE ON MICRO/NANO SENSORS FOR AI, HEALTHCARE, AND ROBOTICS (NSENS), 2018, : 64 - 67
  • [3] Compression of Gait IMU signals Using Sensor Fusion and Compressive Sensing
    Khoshnevis, Seyed Alireza
    Appakaya, Sai Bharadwaj
    Sheybani, Ehsan
    Sankar, Ravi
    2020 WIRELESS TELECOMMUNICATIONS SYMPOSIUM (WTS), 2020,
  • [4] An Integrated System for Gait Analysis using FSRs and an IMU
    Kim, Harin
    Kang, Yeon
    Valencia, David R.
    Kim, Donghan
    2018 SECOND IEEE INTERNATIONAL CONFERENCE ON ROBOTIC COMPUTING (IRC), 2018, : 347 - 351
  • [5] Land and Underwater Gait Analysis Using Wearable IMU
    Monoli, Cecilia
    Fuentez-Perez, Juan Francisco
    Cau, Nicola
    Capodaglio, Paolo
    Galli, Manuela
    Tuhtan, Jeffrey A.
    IEEE SENSORS JOURNAL, 2021, 21 (09) : 11192 - 11202
  • [6] A Study of Trot Gait Control System of a Quadruped Robot Using IMU Sensor
    Mori, Kimihiro
    Ohkubo, Tomoyuki
    Kazuyuki, Kobayashi
    Kajiro, Watanabe
    Tian, Kaiqiao
    Sebi, Nashwan J.
    Cheok, Ka C.
    2022 61ST ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS (SICE), 2022, : 849 - 854
  • [7] Monitoring of Gait Performance Using Dynamic Time Warping on IMU-Sensor Data
    Wang, Xingchen
    Kyrarini, Maria
    Ristic-Durrant, Danijela
    Spranger, Matthias
    Graeser, Axel
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 268 - 273
  • [8] Verification of gait analysis method fusing camera-based pose estimation and an IMU sensor in various gait conditions
    Yamamoto, Masataka
    Shimatani, Koji
    Ishige, Yuto
    Takemura, Hiroshi
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [9] Verification of gait analysis method fusing camera-based pose estimation and an IMU sensor in various gait conditions
    Masataka Yamamoto
    Koji Shimatani
    Yuto Ishige
    Hiroshi Takemura
    Scientific Reports, 12
  • [10] Gait Phase Estimation by Using LSTM in IMU-Based Gait Analysis-Proof of Concept
    Sarshar, Mustafa
    Polturi, Sasanka
    Schega, Lutz
    SENSORS, 2021, 21 (17)