Imaging of hydroxyl radical (.OH) distributions using luminol water during irradiation with low-energy X-rays

被引:0
|
作者
Yamamoto, Seiichi [1 ]
Yabe, Takuya [2 ]
Hirano, Yoshiyuki [2 ]
Kataoka, Jun [1 ]
机构
[1] Waseda Univ, Fac Sci & Engn, Tokyo, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Integrated Hlth Sci, Nagoya, Japan
关键词
Noble liquid detectors (scintillation;   ionization; double-phase); scintillation and light emission processes (solid; gas and liquid scintillators); X-ray detectors; X-ray fluorescence  (XRF) systems; BLOOD; ROS;
D O I
10.1088/1748-0221/17/10/T10004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Reactive hydroxyl radicals (& BULL;OH) play important roles in the biological effects of radiation exposure or radiation therapy, and the distribution of & BULL;OH in water during irradiation is of interest to researchers. However, real-time & BULL;OH distribution measurement during irradiation has so far not been achieved due to the difficulty of detecting & BULL;OH. To make these distribution measurements possible, we attempted the imaging of light emitted from luminol water during irradiation with low-energy X-rays. Imaging of the light emitted from luminol water was conducted using a cooled charge-coupled device (CCD) camera during X-ray irradiation to luminol water at lower energy than the Cherenkov-light threshold. The light emission of luminol water was 25 times higher than that of water, and clear images of light distributions were measured for the luminol water. By carrying out the imaging of luminol water with the addition of a radical scavenger to the luminol water, we could confirm that the emitted light was from & BULL;OH produced in water. With this addition of the radical scavenger, the light intensity decreased as the weight of the scavenger increased. With these results, we confirmed that the detected light distribution in luminol water could be attributed to the & BULL;OH produced by the X-ray irradiation.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] DOSIMETRY OF LOW-ENERGY X-RAYS USING LIF
    LAW, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (01): : 38 - 45
  • [2] LOW-ENERGY COSMIC X-RAYS
    SHUKLA, PG
    WILSON, BG
    ASTROPHYSICAL JOURNAL, 1971, 164 (02): : 265 - &
  • [3] LOW-ENERGY DIFFUSE X-RAYS
    BUNNER, AN
    COLEMAN, PL
    KRAUSHAAR, WL
    MCCAMMON, D
    ASTROPHYSICAL JOURNAL, 1971, 167 (01): : L3 - +
  • [4] ACCURATE DOSIMETRY OF LOW-ENERGY X-RAYS
    LYONS, PB
    BARAN, JA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (02): : 908 - &
  • [5] DETECTION OF LOW-ENERGY COSMIC X-RAYS
    FRANCEY, RJ
    BAIRD, GA
    GREEN, DW
    WILSON, BG
    WOOLLAM, WH
    NUCLEAR INSTRUMENTS & METHODS, 1973, 107 (03): : 589 - 595
  • [6] ELECTRET DOSIMETER FOR LOW-ENERGY X-RAYS
    RICARD, M
    LISBONA, A
    MORUCCI, JP
    ROULLEAU, J
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 129 - 130
  • [7] ATTENUATION OF LOW-ENERGY X-RAYS IN THE AIR
    DIETZSCH, W
    ISOTOPENPRAXIS, 1987, 23 (12): : 456 - 459
  • [8] Dosimetry of Low-Energy Characteristic X-Rays
    Tucker, M.
    Starin, R.
    McCray, M.
    Rakowski, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [9] Dose distribution measurements using luminol water during irradiation of high-energy X-rays from medical linear accelerators (LINAC)
    Yamamoto, Seiichi
    Yamada, Koya
    Yabe, Takuya
    Hirano, Yoshiyuki
    Kataoka, Jun
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [10] FLASH Irradiation of Drosophila Melanogaster Using Low Energy X-Rays
    Hart, A.
    Dudzic, J.
    Eby, J.
    Perlman, S.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E539 - E539