Micro electrical impedance spectroscopy on a needle for ex vivo discrimination between human normal and cancer renal tissues

被引:13
|
作者
Yun, Joho [1 ]
Kim, Hyeon Woo [1 ]
Park, Yangkyu [2 ]
Cha, Jung-Joon [1 ]
Lee, Jeong Zoo [3 ]
Shin, Dong Gil [3 ]
Lee, Jong-Hyun [1 ,2 ]
机构
[1] GIST, Dept Biomed Sci & Engn, Gwangju 500712, South Korea
[2] GIST, Sch Mech Engn, Gwangju 500712, South Korea
[3] Pusan Natl Univ Hosp, Dept Urol, 179 Gudeok Ro, Busan 602739, South Korea
来源
BIOMICROFLUIDICS | 2016年 / 10卷 / 03期
关键词
DIELECTRIC-PROPERTIES; ELECTRODE POLARIZATION; BIOLOGICAL-MATERIALS; RADICAL NEPHRECTOMY; SURVIVAL;
D O I
10.1063/1.4951702
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The ex-vivo discrimination between human normal and cancer renal tissues was confirmed using mu EoN (micro electrical impedance spectroscopy-on-a-needle) by measuring and comparing the electrical impedances in the frequency domain. To quantify the extent of discrimination between dissimilar tissues and to determine the optimal frequency at which the discrimination capability is at a maximum, discrimination index (DI) was employed for both magnitude and phase. The highest values of DI for the magnitude and phase were 5.15 at 1MHz and 3.57 at 1 kHz, respectively. The mean magnitude and phase measured at the optimal frequency for normal tissues were 5013.40 +/- 94.39 X and Omega 68.54 +/- 0.72 degrees, respectively; those for cancer tissues were 4165.19 +/- 70.32 X and Omega 64.10 +/- 0.52 degrees, respectively. A statistically significant difference (p<0.05) between the two tissues was observed at all the investigated frequencies. To extract the electrical properties (resistance and capacitance) of these bio-tissues through curve fitting with experimental results, an equivalent circuit was proposed based on the lEoN structure on the condition that the lEoN was immersed in the bio-tissues. The average and standard deviation of the extracted resistance and capacitance for the normal tissues were 6.22 +/- 0.24 kX and 280.21 +/- 32.25 pF, respectively, and those for the cancer tissues were 5.45 +/- 0.22 kX and 376.32 +/- 34.14 pF, respectively. The electrical impedance was higher in the normal tissues compared with the cancer tissues. The lEoN could clearly discriminate between normal and cancer tissues by comparing the results at the optimal frequency (magnitude and phase) and those of the curve fitting (extracted resistance and capacitance). Published by AIP Publishing.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] DIFFERENTIATION BETWEEN NORMAL AND CANCEROUS RENAL TISSUES USING ELECTRICAL IMPEDANCE SPECTROSCOPY NEEDLE.
    Kim, Hyeon Woo
    Yun, Joho
    Park, Yangkyu
    Shin, Dong Gil
    Lee, Jeong Zoo
    Lee, Jong-Hyun
    Lee, Wan
    Lee, Chang Yell
    JOURNAL OF UROLOGY, 2016, 195 (04): : E1169 - E1169
  • [2] Electrical Impedance Spectroscopy for Ex-Vivo Breast Cancer Tissues Analysis
    Francesco Meani
    Giuseppe Barbalace
    Davide Meroni
    Olivia Pagani
    Ulrike Perriard
    Alberto Pagnamenta
    Andrea Aliverti
    Emanuele Meroni
    Annals of Biomedical Engineering, 2023, 51 : 1535 - 1546
  • [3] Electrical Impedance Spectroscopy for Ex-Vivo Breast Cancer Tissues Analysis
    Meani, Francesco
    Barbalace, Giuseppe
    Meroni, Davide
    Pagani, Olivia
    Perriard, Ulrike
    Pagnamenta, Alberto
    Aliverti, Andrea
    Meroni, Emanuele
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (07) : 1535 - 1546
  • [4] Ex vivo identification of thyroid cancer tissue using electrical impedance spectroscopy on a needle
    Yun, Joho
    Hong, Yong-Tae
    Hong, Ki-Hwan
    Lee, Jong-Hyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 261 : 550 - 557
  • [5] Ex vivo discrimination between normal and pathological tissues in human breast surgical biopsies using bioimpedance spectroscopy
    Chauveau, N
    Hamzaoui, L
    Rochaix, P
    Rigaud, B
    Voigt, JJ
    Morucci, JP
    ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 : 42 - 50
  • [6] Ex vivo HR-MAS magnetic resonance Spectroscopy of normal and malignant human renal tissues
    Righi, Valeria
    Mucci, Adele
    Schenetti, Luisa
    Tosi, Maria Raffaella
    Grigioni, Walter Franco
    Corti, Barbara
    Bertaccini, Alessandro
    Franceschelli, Alessandro
    Sanguedolce, Francesco
    Schiavina, Riccardo
    Martorana, Giuseppe
    Tugnoli, Vitaliano
    ANTICANCER RESEARCH, 2007, 27 (5A) : 3195 - 3204
  • [7] Micro Electrical Impedance Spectroscopy (mEIS) Fabricated on the Curved Surface of a Fine Needle for Biotissue Discrimination
    Kang, Giseok
    Yun, Joho
    Cho, Jin-Seong
    Yoon, JungHan
    Lee, Jong-Hyun
    ELECTROANALYSIS, 2016, 28 (04) : 733 - 741
  • [8] Measurement of electrical impedance in different ex-vivo tissues
    Meroni, Davide
    Bovio, Dario
    Frisoli, Pietro A.
    Aliverti, Andrea
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2311 - 2314
  • [9] Detecting colorectal cancer using electrical impedance spectroscopy: an ex vivo feasibility study
    Pathiraja, Angela
    Ziprin, Paul
    Shiraz, Arsam
    Mirnezami, Reza
    Tizzard, Andrew
    Brown, Brian
    Demosthenous, Andreas
    Bayford, Richard
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (06) : 1278 - 1288
  • [10] Electrical Impedance Spectroscopy (EIS) Measurement of Human Tissues
    Clemente, Fabrizio
    PROCEEDINGS OF THE 2012 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2012), 2012, : 1 - +