Central line-associated bloodstream infection (CLABSI) with three different vascular access in neonatal intensive care unit

被引:3
|
作者
Rabie, Dina [1 ]
Mostafa, Mohammed F. [1 ]
Halim, Rania M. Abdel [2 ]
Ezzat, Ola Ahmad [3 ]
机构
[1] Ain Shams Univ, Fac Med, Dept Pediat, Cairo, Egypt
[2] Ain Shams Univ, Dept Clin Pathol, Fac Med, Cairo, Egypt
[3] Ain Shams Univ, Obstetr & Gynecol Hosp, Fac Med, Cairo, Egypt
关键词
Needleless connector; CLABSI; CLRBSI; Central catheter; Bloodstream infection; Neonates; RISK-FACTORS; CATHETER; PREVENTION;
D O I
10.1186/s43054-022-00108-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Central venous catheters (CVCs) are a mandatory aspect in the neonatal intensive care units. Unfortunately, bloodstream infection is a frequent complication of CVCs. A needleless connector is attached to the end of CVC to allow infusion of fluids. We aimed to assess the effect of needleless connectors on central line-associated blood stream infection, and to assess rate of occurrence of bloodstream infection with the use of three different types of venous access in neonates. Methods: This study is a prospective, randomized, comparative study which was held at the Neonatal Intensive Care, Faculty of Medicine, Ain Shams University. The study recruited 120 neonates who were categorized into three groups according to the type of inserted CVC: group A with umbilical venous catheter, group B with peripherally inserted central catheter, and group C with non-tunneled central venous catheter, and each group was further subdivided into two groups according to the use of needleless connector. Criteria of central line-associated bloodstream infection (CLABSI) and central line-related bloodstream infection (CLRBSI) were applied. Results: The study included 120 neonates, a multivariable logistic regression analysis was held for two predictors (type of CVC and use of needleless connector) of CLABSI/CLRBSI, it revealed that the use of needleless connector was associated with significant lower incidence of CLABSI/CLRBSI (P value < 0.05, adjusted odds ratio [aOR] = 0.303), the use of peripheral inserted central catheter (PICC) was also associated with the lowest incidence of CLABSI/CLRBSI (P value = 0.015, aOR = 0.284). Another multivariable logistic regression analysis was done for four predictors (type of CVC, use of needleless connector, gestational age, and catheter dwell time) which revealed that the gestational age (P value = 0.001, aOR = 0.691) and catheter dwell time (P value = 0.004, aOR = 1.313) were the only independent predictors for the occurrence of CLABSI/CLRBSI. Conclusion: The use of needleless connector can lower the incidence of CLABSI/CLRBSI, PICC line was associated with the lowest incidence of CLABSI/CLRBSI among the three types of CVCs. Low gestational age and long catheter dwell time were found to be the main risk factors for increasing the incidence of CLABSI/CLRBSI.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Central line-associated bloodstream infection (CLABSI) with three different vascular access in neonatal intensive care unit
    Dina Rabie
    Mohammed F. Mostafa
    Rania M. Abdel Halim
    Ola Ahmad Ezzat
    [J]. Egyptian Pediatric Association Gazette, 70
  • [2] Four year surveillance of central line-associated bloodstream infection (CLABSI) in neonatal intensive care unit (NICU)
    A Décary
    R Mandel
    R Rodrigues
    C Frenette
    B Lussier
    [J]. BMC Proceedings, 5 (Suppl 6)
  • [3] Qualitative process evaluation of a central line-associated bloodstream infection (CLABSI) prevention team in the neonatal intensive care unit
    Stroever, Stephanie
    Boston, Kelley
    Ellsworth, Misti
    Cuccaro, Paula
    McCurdy, Sheryl
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2020, 48 (09) : 987 - 992
  • [4] Central Line-Associated Bloodstream Infection in Neonatal Intensive Care Units
    Blanchard, Ana C.
    Fortin, Elise
    Rocher, Isabelle
    Moore, Dorothy L.
    Frenette, Charles
    Tremblay, Claude
    Quach, Caroline
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2013, 34 (11): : 1167 - 1173
  • [5] Incidence of central line-associated bloodstream infection in an intensive care unit
    Espiau, M.
    Pujol, M.
    Campins-Marti, M.
    Planes, A. M.
    Pena, Y.
    Balcells, J.
    Roqueta, J.
    [J]. ANALES DE PEDIATRIA, 2011, 75 (03): : 188 - 193
  • [6] Central line-associated bloodstream infection in infants admitted to a level lll neonatal intensive care unit
    Nielsen, Camilla Littau
    Zachariassen, Gitte
    Holm, Kristina Garne
    [J]. DANISH MEDICAL JOURNAL, 2022, 69 (05):
  • [7] Central Line-Associated Bloodstream Infection: Not Just an Intensive Care Unit Problem
    Whited, Alyssa
    Lowe, Janell M.
    [J]. CLINICAL JOURNAL OF ONCOLOGY NURSING, 2013, 17 (01) : 21 - 24
  • [8] The risk of central line-associated bloodstream infections with different types of central vascular catheters in a multidisciplinary neonatal and pediatric intensive care unit
    Pavcnik-Arnol, Maja
    [J]. SIGNA VITAE, 2013, 8 (01): : 15 - 20
  • [9] STOP CLABSI INITIATIVE: A MULTIDISCIPLINARY TEAM APPROACH FOR PREVENTION OF CENTRAL LINE-ASSOCIATED BLOODSTREAM INFECTIONS (CLABSI) IN THE INTENSIVE CARE UNIT
    Ghosh, Sudeshna
    Nalbandian, Madlena
    Conway, Rashida
    Tabibian, Benjamin
    Reddy, Hari
    [J]. CHEST, 2023, 164 (04) : 5247A - 5247A
  • [10] Effect of a vascular access team on central line-associated bloodstream infections in infants admitted to a neonatal intensive care unit: A systematic review
    Legemaat, Monique M.
    Jongerden, Irene P.
    van Rens, Roland M. F. P. T.
    Zielman, Marjanne
    van den Hoogen, Agnes
    [J]. INTERNATIONAL JOURNAL OF NURSING STUDIES, 2015, 52 (05) : 1003 - 1010