Vibroacoustic Measurements for Detecting Water Leaks in Buried Small-Diameter Plastic Pipes

被引:54
|
作者
Martini, Alberto [1 ]
Troncossi, Marco [1 ]
Rivola, Alessandro [1 ]
机构
[1] Univ Bologna, DIN Dept Ind Engn, Viale Risorgimento 2, I-40136 Bologna, Italy
关键词
Water-filled pipe; Plastic service pipe; Vibration monitoring; Leak detection; DISTRIBUTION NETWORK; FILLED PIPES; GREECE; PERFORMANCE; NOISE;
D O I
10.1061/(ASCE)PS.1949-1204.0000287
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Leak detection is an essential topic within the policies of water loss management in drinking-water supply networks. This paper reports the results of an experimental campaign performed for assessing the sensitivity to water leaks of measurements of different vibroa-coustic phenomena. The study represents the first stage of research aimed at developing a device for automatic leak detection in service pipes of water distribution networks. Leaks were artificially induced on a plastic pipe (length of 28 m and diameter of 32 mm) of a buried experimental facility. Vibroacoustic phenomena related to the leaking flow were monitored using a hydrophone and two accelerometers. A satisfactory leak-detection performance was achieved by processing the signals from both kinds of transducers. (C) 2017 American Society of Civil Engineers.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Novel Electrical Technique for Detecting Water Leaks in Buried Plastic Water Distribution Pipes
    Hadji, Abdelhafid
    Flazi, Samir
    Bouzid, Mohammed Abdelfettah
    [J]. JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2022, 13 (04)
  • [2] Detecting leaks in plastic pipes
    Hunaidi, O
    Chu, W
    Wang, A
    Guan, W
    [J]. JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2000, 92 (02): : 82 - 94
  • [3] SIMPLIFIED PROCEDURE FOR HYDRAULIC DESIGN OF SMALL-DIAMETER PLASTIC PIPES
    Yildirim, Guerol
    [J]. IRRIGATION AND DRAINAGE, 2009, 58 (02) : 209 - 233
  • [4] Reliability of Infrared Thermography in Detecting Leaks in Buried Water Reticulation Pipes
    Bach, Peter M.
    Kodikara, Jayantha K.
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2017, 10 (09) : 4210 - 4224
  • [5] The design of a laboratory facility for evaluating the structural response of small-diameter buried pipes
    Brachman, RWI
    Moore, ID
    Rowe, RK
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 2000, 37 (02) : 281 - 295
  • [6] The performance of a laboratory facility for evaluating the structural response of small-diameter buried pipes
    Brachman, RWI
    Moore, ID
    Rowe, RK
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 2001, 38 (02) : 260 - 275
  • [7] Leak Detection in Water-Filled Small-Diameter Polyethylene Pipes by Means of Acoustic Emission Measurements
    Martini, Alberto
    Troncossi, Marco
    Rivola, Alessandro
    [J]. APPLIED SCIENCES-BASEL, 2017, 7 (01):
  • [8] Locating Leaks in Plastic Water Pipes
    Lange, Gösta
    [J]. Opflow, 2002, 28 (07) : 1 - 10
  • [9] Detection of leaks in buried plastic water distribution pipes in urban places - A case study
    Stampolidis, A
    Soupios, P
    Vallianatos, F
    Tsokas, GN
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL WORKSHOP ON ADVANCED GROUND PENETRATING RADAR, 2003, : 120 - 124
  • [10] EXPERIMENTAL-STUDY ON FLOW-RESISTANCE LAW FOR SMALL-DIAMETER PLASTIC PIPES
    BAGARELLO, V
    FERRO, V
    PROVENZANO, G
    PUMO, D
    [J]. JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 1995, 121 (05) : 313 - 316