Data logging variables and speech perception in prelingually deafened pediatric cochlear implant users

被引:8
|
作者
Cesur, Sidika [1 ]
Yuksel, Mustafa [2 ]
Ciprut, Ayca [1 ]
机构
[1] Marmara Univ, Fac Med, Audiol Dept, Istanbul, Turkey
[2] Marmara Univ, Inst Hlth Sci, Audiol & Speech Disorders Program, Istanbul, Turkey
关键词
Cochlear implant; Speech recognition; Data logging; Listening environment; MULTICENTER CLINICAL-EVALUATION; SPOKEN LANGUAGE; HEARING-LOSS; CHILDREN; AGE; PREDICTORS; OUTCOMES; NOISE; PERFORMANCE; LIFE;
D O I
10.1016/j.ijporl.2020.110003
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: To investigate the relationship among objectively gathered data logging measurements, patient-related variables, and speech recognition performance of pediatric CI users. Methods and materials: Thirty-two prelingually implanted children who have the ability to perform word discrimination test were included in this study. To reveal the relationship between speech perception abilities and auditory exposure, seven data logging variables were analyzed: "on-air," "off-air," "coil-off," "speech," "speech in noise," "music" and "noise. In addition, implantation age (months) and CI usage duration (months) were taken into account. Finally, it was investigated the differences between unilateral, sequential bilateral, and simultaneous bilateral CI users in terms of all study variables. Results: The average on-air time ranged between 10.52 and 12.30 in the groups. In the case of sequential implantation, smaller on-air and higher coil off values were observed with the second CI. In the case of simultaneous bilateral implantation, data logging measurements were almost the same in both implants. WRS was significantly correlated (p < 0.05) with on-air time (r = 0.62), coil-off count (r = - 0.48), chronological age (r = -0.48), and CI duration (r = 0.44). Multiple linear regression model was fit to predict the WRS, with on-air time, CI duration, and chronological age as predictors. Conclusions: The critical importance of early intervention and long-term use of CI is well-established in the literature and is also corroborated by our findings. However, the key findings of the present study are that consistent CI use and the quality of daily listening environment also exerted a major and positive effect on the speech recognition performance of pediatric CI users. Therefore, during the monitoring of pediatric CI recipients, it is important to know the device usage data in order to detect problems in the early stages after CI.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Long-term speech perception performance in prelingually deafened adult cochlear implant recipients
    Yoshida, Haruo
    Kanda, Yukihiko
    Satoh, Chisei
    Kumai, Yoshihiko
    Takahashi, Haruo
    [J]. COCHLEAR IMPLANTS INTERNATIONAL, 2023, 24 (05) : 243 - 249
  • [2] Speech Intelligibility as a Predictor of Cochlear Implant Outcome in Prelingually Deafened Adults
    van Dijkhuizen, Janette N.
    Beers, Mieke
    Boermans, Peter-Paul B. M.
    Briaire, Jeroen J.
    Frijns, Johan H. M.
    [J]. EAR AND HEARING, 2011, 32 (04): : 445 - 458
  • [3] Predictor variables of speech intelligibility in prelingually deafened children with cochlear implants
    Yoon, MS
    Sim, HS
    Lee, YK
    Park, HY
    Kim, CS
    [J]. COCHLEAR IMPLANTS - AN UPDATE, 2002, : 383 - 386
  • [4] Speech perception performance of prelingually deafened children and adolescents with nucleus 22-channel cochlear implant
    Huang, WH
    Huang, TS
    [J]. COCHLEAR IMPLANT AND RELATED SCIENCES UPDATE, 1997, 52 : 224 - 228
  • [5] Speech-perception performance in prelingually deafened French children using the nucleus multichannel cochlear implant
    Uziel, AS
    ReuillardArtieres, F
    Sillon, M
    Vieu, A
    Mondain, M
    Piron, JP
    Tobey, EA
    [J]. AMERICAN JOURNAL OF OTOLOGY, 1996, 17 (04): : 559 - 568
  • [6] CHANGES IN CONSONANTS AND VOWELS PRODUCED IN THE SPEECH OF A PRELINGUALLY DEAFENED COCHLEAR IMPLANT USER
    DYSON, AT
    HOLMES, AE
    MARTIN, S
    KEMKER, FJ
    [J]. VOLTA REVIEW, 1993, 95 (01) : 11 - 19
  • [7] Amplitude Modulation Detection and Speech Recognition in Late-Implanted Prelingually and Postlingually Deafened Cochlear Implant Users
    De Ruiter, Anke M.
    Debruyne, Joke A.
    Chenault, Michelene N.
    Francart, Tom
    Brokx, Jan P. L.
    [J]. EAR AND HEARING, 2015, 36 (05): : 557 - 566
  • [8] Psychoacoustic Performance and Music and Speech Perception in Prelingually Deafened Children with Cochlear Implants
    Jung, Kyu Hwan
    Won, Jong Ho
    Drennan, Ward R.
    Jameyson, Elyse
    Miyasaki, Gary
    Norton, Susan J.
    Rubinstein, Jay T.
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2012, 17 (03) : 189 - 197
  • [9] COCHLEAR IMPLANT IN PRELINGUALLY DEAFENED ORALIST ADULTS: SPEECH PERCEPTION OUTCOME, SUBJECTIVE BENEFITS AND QUALITY OF LIFE IMPROVEMENT
    Bellelli, S.
    Forli, F.
    Berrettini, S.
    Turchetti, G.
    [J]. VALUE IN HEALTH, 2016, 19 (07) : A561 - A561
  • [10] Contribution of Nonimplanted Ear to Pitch Perception for Prelingually Deafened Cochlear Implant Recipients
    Chen, Joshua Kuang-Chao
    Chuang, Ann Yi-Chiun
    McMahon, Catherine
    Tung, Tao-Hsin
    Li, Lieber Po-Hung
    [J]. OTOLOGY & NEUROTOLOGY, 2014, 35 (08) : 1409 - 1414