Robot-assisted total knee arthroplasty in haemophilic arthropathy

被引:31
|
作者
Kim, K. -I. [1 ]
Kim, D. -K. [1 ]
Juh, H. -S. [1 ]
Khurana, S. [1 ]
Rhyu, K. -H. [1 ]
机构
[1] Kyung Hee Univ Hosp Gangdong, Ctr Joint Dis & Rheumatism, Dept Orthopaed Surg, 149 Sangil Dong, Seoul 134090, South Korea
关键词
haemophilic arthropathy; alignment; robot-assisted; total knee arthroplasty; COMPONENT PLACEMENT; BLOOD-LOSS; REPLACEMENT; ALIGNMENT; ACCURACY; SURGERY; NAVIGATION; SYSTEM;
D O I
10.1111/hae.12875
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Execution of total knee arthroplasty (TKA) in end-stage haemophilic arthropathy is challenging because of soft tissue fibrosis, flexion contractures, poor quality of the bone, and the altered bony anatomy. Restoring the lower limb alignment and achieving range of motion (ROM) is difficult. Robots have been used in TKA to reduce the chances of malalignment and improve accuracy and precision. However, there has been no report in literature on use of robots for TKA in haemophilic arthropathy. The aim of this study was to evaluate whether robot-assisted TKA can be successfully carried out in haemophilic arthropathy and what precision could be obtained. Methods: Thirty-two robot-assisted TKA were evaluated in 29 haemophilia patients. The mean follow up period was 5 years (range, 3-7 years). Hip-knee-ankle (HKA) axis, component angles, and radiographic loosening were evaluated. Clinically ROM, Knee Society scores (KSS) and SF-36 were assessed. Results: The HKA axis was within a range of 0 +/- 3 degrees in 30 knees (93.8%). The alignment of the components also presented satisfying results. KSS were improved from 27.1 to 82.8 postoperatively (P < 0.001). The ROM was improved from 70.7 to 84.7 postoperatively (P = 0.006). Complications included early haematoma in three knees, heterotopic ossification in three knees, periprosthetic infection in two knees. Conclusions: Though robotic TKA gives excellent accuracy of lower limb and component alignment, expensive cost, additional preparation time, longer operation time with similar clinical results in haemophilic arthropathy should be concerned.
引用
收藏
页码:446 / 452
页数:7
相关论文
共 50 条
  • [1] Robot-assisted total knee arthroplasty
    Bellemans, Johan
    Vandenneucker, Hilde
    Vanlauwe, Johan
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) : 111 - 116
  • [2] A modular total knee arthroplasty in haemophilic, arthropathy
    Innocenti, M.
    Civinini, R.
    Carulli, C.
    Villano, M.
    Linari, S.
    Morfini, M.
    [J]. KNEE, 2007, 14 (04): : 264 - 268
  • [3] Computer-navigated total knee arthroplasty in haemophilic arthropathy
    Cho, K. -Y.
    Kim, K. -I.
    Khurana, S.
    Cho, S. -W.
    Kang, D. -G.
    [J]. HAEMOPHILIA, 2013, 19 (02) : 259 - 266
  • [4] Noise exposure during robot-assisted total knee arthroplasty
    Tim, Hoenecke
    Michael, Schwarze
    Matthias, Wangenheim
    Savov, Peter
    Henning, Windhagen
    Max, Ettinger
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 2813 - 2819
  • [5] Robot-assisted Minimally Invasive Total Knee Arthroplasty System
    Zhang, Yinghao
    Li, Weiquan
    Chen, Jiahe
    Song, Guoli
    Qi, Yansong
    Xu, Yongsheng
    Wang, Junchen
    [J]. Jiqiren/Robot, 2021, 43 (04): : 386 - 394
  • [6] Noise exposure during robot-assisted total knee arthroplasty
    Tim Hönecke
    Michael Schwarze
    Matthias Wangenheim
    Peter Savov
    Henning Windhagen
    Max Ettinger
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 2813 - 2819
  • [7] Haemophilic;: Arthropathy:: Assessment of quality of life after total knee arthroplasty
    Schick, M
    Stucki, G
    Rodriguez, M
    Meili, EO
    Huber, E
    Michel, BA
    Brühlmann, P
    [J]. CLINICAL RHEUMATOLOGY, 1999, 18 (06) : 468 - 472
  • [8] Lateral approach to the total knee arthroplasty in haemophilic arthropathy: Case series
    Zorzi, Alessandro
    Pagnano, Rodrigo
    Feldberg, Glenda
    Bosso, Janaina
    Ozelo, Margareth C.
    [J]. HAEMOPHILIA, 2021, 27 : 17 - 17
  • [9] Haemophilic; Arthropathy: Assessment of Quality of Life After Total Knee Arthroplasty
    M. Schick
    G. Stucki
    M. Rodriguez
    E. O. Meili
    E. Huber
    B. A. Michel
    P. Brühlmann
    [J]. Clinical Rheumatology, 1999, 18 : 468 - 472
  • [10] Robot-Assisted Unicompartmental Knee Arthroplasty
    Pearle, Andrew D.
    O'Loughlin, Padhraig F.
    Kendoff, Daniel O.
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (02): : 230 - 237