Fabrication of Three Fire-retardant Poplar Gluing Composite Lumbers and Evaluation of Their Fire-retardant and Smoke-suppressant Performance

被引:0
|
作者
Wu Yi-qiang [1 ]
Peng Wan-xi [1 ]
Li Xin-gong [1 ]
Hu Yun-chu [1 ]
Zheng Xia [1 ]
机构
[1] Cent S Univ Forestry & Technol, Coll Mat Sci & Engn, Changsha 410004, Hunan, Peoples R China
关键词
poplar gluing composite lumber; smoke-suppressant performance; fire-retardant performance; evaluation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wood-based composites is widely used in building and interior decoration field. However, it is easy for wood to get burnt, and abundant toxic smoke generating during the burning process has caused great casualties and property loss. In this study, poplar wood was chosen as test materials, and three fire-retardant were selected, i.e. the inorganic X type fire-retardant and the organic fire-retardant named F type, and the Z type fire-retardant which is an ordinary organic and inorganic combination fire-retardant and contains element Cl and N. Then after different treated process, three types of gluing composite lumbers were prepared. Thereafter, DSC, TG etc were adopted, and the fire-retardant, smoke-suppressant and mechanical performance of lumber were compared and evaluated. The results indicated that : (1) In a certain range of fire-retardant concentration, with the increase of concentration, all of these three fire-retardant had a much better fire-retardant and smoke-suppressant performance while the bonding strength of composite didn't show much variation and met the requirement of GB. (2) For the F type fire-retardant, when the concentration and process technique were the same, the fire-retarded performance of Y type was better than the other two types, and it also had a good smoke-suppressant performance. (3) X type fire-retardant had an excellent fire-retardant and smoke-suppressant performance when its concentration was relatively large. (4) For Z type fire-retardant, it had a good fire-retarding performance with a relatively small smoke amount, but some toxic gas such as HCI and NH3 was generated.
引用
收藏
页码:3760 / 3764
页数:5
相关论文
共 50 条
  • [1] Fire-retardant and smoke-suppressant rigid polyurethane foam composites
    Akar, Ahmet
    Degirmenci, Berrin
    Koken, Nesrin
    [J]. PIGMENT & RESIN TECHNOLOGY, 2023, 52 (02) : 237 - 245
  • [2] Smoke suppressant and fire-retardant polyurethane-polyisocyanurate (PIR) foam
    Degirmenci, Berrin
    Koken, Nesrin
    Akar, Ahmet
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2023, 140 (36)
  • [3] FIRE-RETARDANT BELTING
    SILVEY, DH
    [J]. RUBBER CHEMISTRY AND TECHNOLOGY, 1985, 58 (01): : 203 - 204
  • [4] FIRE-RETARDANT BELTING
    SILVEY, DH
    [J]. CIM BULLETIN, 1982, 75 (844): : 120 - 122
  • [5] FIRE-RETARDANT MATERIALS
    BAJAJ, P
    [J]. BULLETIN OF MATERIALS SCIENCE, 1992, 15 (01) : 67 - 76
  • [6] Fire-retardant filters
    不详
    [J]. MICRO, 1995, 13 (02): : 45 - 45
  • [7] SMOKE TOXICITY OF FIRE-RETARDANT TELEVISION CABINETS
    ROBINSON, RS
    DRESSLER, DP
    DUGGER, DL
    CUKOR, P
    [J]. JOURNAL OF COMBUSTION TOXICOLOGY, 1977, 4 (04): : 435 - 453
  • [8] FEDERATED PIONEERS FIRE-RETARDANT
    不详
    [J]. BUSINESS AND COMMERCIAL AVIATION, 1984, 55 (03): : 108 - &
  • [9] FIRE-RETARDANT CABLE SYSTEMS
    MCILVEEN, EE
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1975, IA11 (03) : 301 - 307
  • [10] INTUMESCENT FIRE-RETARDANT SYSTEMS
    CAMINO, G
    COSTA, L
    MARTINASSO, G
    [J]. POLYMER DEGRADATION AND STABILITY, 1989, 23 (04) : 359 - 376