Moisture determination of tritium tracers utilizing near-infrared spectroscopy

被引:0
|
作者
Marques, Rosemary [1 ]
Waterhouse, David J. [1 ]
Helmy, Roy [1 ]
机构
[1] Merck Res Labs, Dept Proc & Analyt Chem, Rahway, NJ 07065 USA
关键词
near-IR; moisture determination; stability; tracers; WATER; EVAPORATION; STABILITY;
D O I
10.1002/jlcr.3394
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Tritium tracers are frequently used in biological assays during the drug discovery process because of their high specific activity and relative ease of synthesis. However, this high specific activity, along with other contributing factors, can lead to an increased rate of radiolytic decomposition. As a result, following long-term storage tritium tracers often require purification. Understanding the elements that cause radiolytic decomposition is extremely important to extend the storage life, and consequently reduce unnecessary inventory purifications. One of these elements is the presence of water in tritium tracers. Upon investigation, it was discovered that aside from the relatively common tritium/water exchange that could occur, residual water could also contribute significantly to the decomposition of tritium tracers. A near-infrared method was developed utilizing a portable device to measure the water content in tritium tracers rapidly and without sample destruction. This method proved to be quick, efficient, and achieved an error less than 5% compared to that of traditional Karl Fischer titration. Method validation was performed and good accuracy, linearity, limit of detection and quantitation were all established.
引用
收藏
页码:294 / 296
页数:3
相关论文
共 50 条
  • [1] Determination of Ribavirin and Moisture in Pharmaceuticals by Near-Infrared Spectroscopy
    Yang, Hongqin
    Liu, Yanxin
    Huang, Yanmei
    Tang, Bin
    Guo, Dan
    Li, Hui
    [J]. ANALYTICAL LETTERS, 2016, 49 (13) : 2077 - 2091
  • [2] DETERMINATION OF MOISTURE IN CHEDDAR CHEESE BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    WEHLING, RL
    PIERCE, MM
    [J]. JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1988, 71 (03): : 571 - 574
  • [3] DETERMINATION OF MOISTURE IN SINGLE-CELL PROTEIN UTILIZING PHOTOACOUSTIC-SPECTROSCOPY IN THE NEAR-INFRARED REGION
    CASTLEDEN, SL
    KIRKBRIGHT, GF
    MENON, KR
    [J]. ANALYST, 1980, 105 (1256) : 1076 - 1081
  • [4] MOISTURE DETERMINATION BY NEAR-INFRARED SPECTROMETRY
    VORNHEDER, PF
    BRABBS, WJ
    [J]. ANALYTICAL CHEMISTRY, 1970, 42 (12) : 1454 - +
  • [5] Determination of in vivo skin moisture level by near-infrared reflectance spectroscopy
    Saknite, Inga
    Spigulis, Janis
    [J]. OPTICAL DIAGNOSTICS AND SENSING XV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2015, 9332
  • [6] DETERMINATION OF PROTEIN AND MOISTURE IN GROUND WHEAT BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    DOWNEY, G
    BYRNE, S
    [J]. IRISH JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 1983, 7 (02): : 135 - 146
  • [7] THE DETERMINATION OF PROTEIN, FAT AND MOISTURE IN BREAD BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    OSBORNE, BG
    BARRETT, GM
    CAUVAIN, SP
    FEARN, T
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1984, 35 (08) : 940 - 945
  • [8] Gas chromatography as a reference method for moisture determination by near-infrared spectroscopy
    Zhou, XJ
    Hines, PA
    White, KC
    Borer, MW
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (02) : 390 - 394
  • [9] MOISTURE IN SKIN BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    WALLING, PL
    DABNEY, JM
    [J]. JOURNAL OF THE SOCIETY OF COSMETIC CHEMISTS, 1989, 40 (03): : 151 - 171
  • [10] Global regression model for moisture content determination using near-infrared spectroscopy
    Clavaud, Matthieu
    Roggo, Yves
    Degardin, Klara
    Sacre, Pierre-Yves
    Hubert, Philippe
    Ziemons, Eric
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2017, 119 : 343 - 352