Real-time ultrasound elastography of the Achilles tendon in patients with cerebral palsy: is there a correlation between strain ratio and biomechanical indicators?

被引:7
|
作者
Ozturk, Mehmet [1 ]
Sayinbatur, Bahattin [2 ]
机构
[1] Diyarbakir Childrens Hosp, Dept Pediat Radiol, TR-21100 Diyarbakir, Turkey
[2] Diyarbakir Childrens Hosp, Dept Pediat Neurol, TR-21100 Diyarbakir, Turkey
关键词
Elastography; Cerebral palsy; Achilles tendon; Strain index; PATTERN DESCRIPTION; ELASTICITY; SONOELASTOGRAPHY; DIAGNOSIS; TISSUES;
D O I
10.1007/s10396-017-0800-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our aim was to comparatively investigate the strain ratio and thickness of the Achilles tendon in children with cerebral palsy (CP), and to elucidate whether there is a correlation between biomechanical features of the Achilles tendon and strain ratio. A total of 155 participants (72 CP patients and 83 healthy controls) who underwent real-time elastography of both Achilles tendons were studied. A linear transducer (4.8-11.0 MHz) was used to obtain the images. Correlation analysis between age, length, and thickness of the Achilles tendon, and strain ratio (SR) was performed by means of Pearson correlation and Spearman's rho tests. Comparison of results obtained from CP patients and controls showed that the length of the Achilles tendon was shorter (p < 0.001) and SR was higher (p < 0.001) in CP patients. In CP patients, there was a positive correlation between SR and age and between SR and the thickness and length of the Achilles tendon (p < 0.001 for all). Furthermore, the length of the tendon and age were positively associated (p < 0.001). ROC analysis revealed that the cut-off value for SR was 1.89. The results of the present study demonstrated that real-time elastography can constitute a simple, practical, and noninvasive method for evaluation of the elasticity of the Achilles tendon in children with CP.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 50 条
  • [1] Real-time ultrasound elastography of the Achilles tendon in patients with cerebral palsy: is there a correlation between strain ratio and biomechanical indicators?
    Mehmet Öztürk
    Bahattin Sayinbatur
    [J]. Journal of Medical Ultrasonics, 2018, 45 : 143 - 148
  • [2] Real-time ultrasound elastography of the normal Achilles tendon: reproducibility and pattern description
    Drakonaki, E. E.
    Allen, G. M.
    Wilson, D. J.
    [J]. CLINICAL RADIOLOGY, 2009, 64 (12) : 1196 - 1202
  • [3] Real-time ultrasound elastography evaluation of achilles tendon properties in patients with mild hemiplegic stroke after rehabilitation training
    Shao, Yu-Hong
    Peng, Ze
    Kong, Xun
    Wang, Bin
    Zhang, Hui
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (03) : 713 - 723
  • [4] Evaluation of normal and pathological Achilles tendon by real-time shear wave elastography
    Petrescu, Pompiliu Horatiu
    Izvernariu, Dragos Andrei
    Iancu, Catalina
    Dinu, Gabriel Ovidiu
    Crisan, Dan
    Popescu, Simona Alina
    Sirli, Roxana Lucia Denisa
    Nistor, Bogdan Mihai
    Rautia, Ion Calin
    Lazureanu, Dorela Codruta
    Dema, Sorin
    Prejbeanu, Ion Radu
    Sporea, Ioan
    [J]. ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2016, 57 (02): : 785 - 790
  • [5] BIOMECHANICAL GATE ANALYSIS AFTER ELONGATION OF THE ACHILLES-TENDON BY PATIENTS WITH CEREBRAL-PALSY
    MURRI, A
    FLEISS, O
    FLEISS, H
    POKORNY, H
    [J]. WIENER MEDIZINISCHE WOCHENSCHRIFT, 1982, 132 (21) : 507 - 513
  • [6] Real-time sonoelastography of Achilles tendon in patients with ankylosing spondylitis
    Turan, Aynur
    Tufan, Abdurrahman
    Mercan, Ridvan
    Teber, Mehmet Akif
    Tezcan, Mehmet Engin
    Bitik, Berivan
    Goker, Berna
    Haznedaroglu, Seminur
    [J]. SKELETAL RADIOLOGY, 2013, 42 (08) : 1113 - 1118
  • [7] Real-time sonoelastography of Achilles tendon in patients with ankylosing spondylitis
    Aynur Turan
    Abdurrahman Tufan
    Rıdvan Mercan
    Mehmet Akif Teber
    Mehmet Engin Tezcan
    Berivan Bitik
    Berna Goker
    Seminur Haznedaroğlu
    [J]. Skeletal Radiology, 2013, 42 : 1113 - 1118
  • [8] Can real-time ultrasound elastography using the color score and strain ratio differentiate between benign and malignant solitary thyroid nodules?
    Refaat, Rania
    Kamel, Amr
    Elganzory, Mahmoud
    Awad, Nahla M.
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (01): : 75 - 87
  • [9] Real-Time Elastography: Strain Ratio Measurements Are Influenced by the Position of the Reference Area
    Havre, R. F.
    Waage, J. R.
    Gilja, O. H.
    Odegaard, S.
    Nesje, L. B.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2012, 33 (06): : 559 - 568
  • [10] Real time endoscopic ultrasound elastography and strain ratio in the diagnosis of solid pancreatic lesions
    Hussein Okasha
    Shaimaa Elkholy
    Ramy El-Sayed
    Mohamed-Naguib Wifi
    Mohamed El-Nady
    Walid El-Nabawi
    Waleed A El-Dayem
    Mohamed I Radwan
    Ali Farag
    Yahya El-sherif
    Emad Al-Gemeie
    Ahmed Salman
    Mohamed El-Sherbiny
    Ahmed El-Mazny
    Reem E Mahdy
    [J]. World Journal of Gastroenterology, 2017, 23 (32) : 5962 - 5968