Evaluation of sampling methods for toxicological testing of indoor air particulate matter

被引:5
|
作者
Tirkkonen, Jenni [1 ]
Taubel, Martin [1 ,2 ]
Hirvonen, Maija-Riitta [1 ,2 ]
Leppanen, Hanna [1 ,2 ]
Lindsley, William G. [3 ]
Chen, Bean T. [3 ]
Hyvarinen, Anne [2 ]
Huttunen, Kati [1 ]
机构
[1] Univ Eastern Finland, Dept Environm Sci, Kuopio, Finland
[2] Natl Inst Hlth & Welf, Dept Hlth Protect, Living Environm & Hlth Unit, Kuopio, Finland
[3] Ctr Dis Control & Prevent, NIOSH, Morgantown, WV USA
关键词
Indoor air; in vitro; moisture damage; particulate matter; sampling; toxicity testing; MOISTURE-DAMAGED BUILDINGS; DUST; DETERMINANTS; ENDOTOXIN; EXPOSURE; ERGOSTEROL; PARTICLES; COLLECTOR;
D O I
10.1080/08958378.2016.1210702
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNF) were determined after 24h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.
引用
收藏
页码:500 / 507
页数:8
相关论文
共 50 条
  • [1] Comparison of sampling methods of indoor air particulate matter for in vitro exposure studies
    Nordberg, Maria-Elisa
    Taubel, Martin
    Jalkanen, Kaisa
    Hyvarinen, Anne
    Huttunen, Kati
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [3] Role of microbial and chemical composition in toxicological properties of indoor and outdoor air particulate matter
    Happo, Mikko S.
    Sippula, Olli
    Jalava, Pasi I.
    Rintala, Helena
    Leskinen, Ari
    Komppula, Mika
    Kuuspalo, Kari
    Mikkonen, Santtu
    Lehtinen, Kari
    Jokiniemi, Jorma
    Hirvonen, Maija-Riitta
    [J]. PARTICLE AND FIBRE TOXICOLOGY, 2014, 11
  • [4] Role of microbial and chemical composition in toxicological properties of indoor and outdoor air particulate matter
    Mikko S Happo
    Olli Sippula
    Pasi I Jalava
    Helena Rintala
    Ari Leskinen
    Mika Komppula
    Kari Kuuspalo
    Santtu Mikkonen
    Kari Lehtinen
    Jorma Jokiniemi
    Maija-Riitta Hirvonen
    [J]. Particle and Fibre Toxicology, 11
  • [5] Seasonal variation in the toxicological properties of size-segregated indoor and outdoor air particulate matter
    Happo, Mikko
    Markkanen, Ari
    Markkanen, Piia
    Jalava, Pasi
    Kuuspalo, Kari
    Leskinen, Ari
    Sippula, Olli
    Lehtinen, Kari
    Jokiniemi, Jorma
    Hirvonen, Maija-Riitta
    [J]. TOXICOLOGY IN VITRO, 2013, 27 (05) : 1550 - 1561
  • [6] SAMPLING OF PARTICULATE MATTER IN AMBIENT AIR
    DEWORM, JP
    [J]. STAUB REINHALTUNG DER LUFT, 1978, 38 (02): : 70 - 70
  • [7] Indoor air sampling for fine particulate matter and black carbon in industrial communities in Pittsburgh
    Tunno, Brett J.
    Shields, Kyra Naumoff
    Cambal, Leah
    Tripathy, Sheila
    Holguin, Fernando
    Lioy, Paul
    Clougherty, Jane E.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 536 : 108 - 115
  • [8] Particulate matter sampling to assess air pollution
    Materano-Escalona, Lisbett Susana
    [J]. NATURE REVIEWS EARTH & ENVIRONMENT, 2024, 5 (04) : 230 - 230
  • [9] Particulate matter sampling to assess air pollution
    Lisbett Susana Materano-Escalona
    [J]. Nature Reviews Earth & Environment, 2024, 5 : 230 - 230
  • [10] INDOOR/OUTDOOR CORRELATIONS REGARDING INDOOR AIR POLLUTION WITH PARTICULATE MATTER
    Bucur, Elena
    Danet, Andrei
    [J]. ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2019, 18 (02): : 425 - 432