Microwave-immobilized polybutadiene stationary phase for reversed-phase high-performance liquid chromatography

被引:12
|
作者
Lopes, NP [1 ]
Collins, KE [1 ]
Jardim, ICSF [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, LABCROM, Lab Pesquisas & Cromatol Liquida, BR-13084971 Campinas, SP, Brazil
关键词
stationary phases; LC; polybutadiene-silica stationary phases; microwave-assisted immobilization;
D O I
10.1016/j.chroma.2003.09.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polybutadiene (PBD) has been immobilized on high-performance liquid chromatography (HPLC) silica by microwave radiation at various power levels (52-663 W) and actuation times (3-60 min). Columns prepared from these reversed-phase HPLC materials, as well as from similar non-irradiated materials, were tested with standard sample mixtures and characterized by elemental analysis (%C) and infrared spectroscopy. A microwave irradiation of 20 min at 663 W gives a layer of immobilized PBD that presented good performance. Longer irradiation times give thicker immobilized layers having less favorable chromatographic properties. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 50 条
  • [1] Preparation of a polybutadiene stationary phase immobilized by γ radiation for reversed-phase high-performance liquid chromatography
    Lopes, NP
    Collins, KE
    Jardim, ICSF
    JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) : 77 - 85
  • [2] Polysiloxane-encapsulated stationary phase for reversed-phase high-performance liquid chromatography
    S. X. Jiang
    R. Q. Yang
    L. R. Chen
    Chromatographia, 1997, 44 : 263 - 266
  • [3] Polysiloxane-encapsulated stationary phase for reversed-phase high-performance liquid chromatography
    Jiang, SX
    Yang, RQ
    Chen, LR
    CHROMATOGRAPHIA, 1997, 44 (5-6) : 263 - 266
  • [4] Development of some stationary phases for reversed-phase high-performance liquid chromatography
    Kirkland, JJ
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) : 9 - 21
  • [5] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HEARN, MTW
    METHODS IN ENZYMOLOGY, 1984, 104 : 190 - 212
  • [6] Estimation of the phase ratio in reversed-phase high-performance liquid chromatography
    Moldoveanu, Serban
    David, Victor
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1381 : 194 - 201
  • [7] An approach to the evaluation and comparison of reversed-phase high-performance liquid chromatography stationary phases
    Law, B
    Houghton, SJ
    Ballard, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (03) : 443 - 453
  • [8] EFFECT OF STATIONARY PHASE SOLVATION ON SHAPE SELECTIVITY IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    COLE, SR
    DORSEY, JG
    JOURNAL OF CHROMATOGRAPHY, 1993, 635 (02): : 177 - 186
  • [9] DETERMINATION OF HYDROPHOBIC PARAMETERS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - EFFECT OF STATIONARY PHASE
    BRAUMANN, T
    GENIESER, HG
    LULLMANN, C
    JASTORFF, B
    CHROMATOGRAPHIA, 1987, 24 : 777 - 782
  • [10] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF BLEOMYCIN
    RZESZOTARSKI, WJ
    ECKELMAN, WC
    REBA, RC
    JOURNAL OF CHROMATOGRAPHY, 1976, 124 (01): : 88 - 91