Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis

被引:12
|
作者
Ibrahim, Adam [1 ]
Chrcanovic, Bruno Ramos [2 ]
机构
[1] Malmo Univ, Fac Odontol, S-21421 Malmo, Sweden
[2] Malmo Univ, Fac Odontol, Dept Prosthodont, S-21421 Malmo, Sweden
关键词
dental implant; failure; marginal bone loss; fresh extraction socket; healed site; systematic review; meta-analysis; meta-regression; ARCH FIXED PROSTHESES; PLACED SINGLE IMPLANTS; IMMEDIATE NON-OCCLUSAL; 5-YEAR FOLLOW-UP; PERIODONTALLY COMPROMISED PATIENTS; RANDOMIZED CLINICAL-TRIAL; WIDE-DIAMETER IMPLANTS; QUALITY-OF-LIFE; ANTERIOR MAXILLA; DELAYED PLACEMENT;
D O I
10.3390/ma14247903
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The present review aimed to evaluate the difference of dental implant failure rates and marginal bone loss (MBL) between implants inserted in fresh extraction sockets or healed sites. Electronic search was undertaken in three databases, plus manual search of journals, including studies randomized or not. Meta-analyses were performed besides meta-regressions, in order to verify how the odds ratio (OR) and MBL were associated with follow-up time. The review included 163 publications. Altogether, there were 17,278 and 38,738 implants placed in fresh extraction sockets and healed sites, respectively. Pairwise meta-analyses showed that implants in sockets had a higher failure risk in comparison to healed sites: OR 1.349, all studies included; OR 2.070, only prospective non-RCTs; OR 2.487, only RCTs (all p < 0.001). The difference in implant failure between the groups was statistically significant in the maxilla (OR 1.616, p = 0.029), but not in the mandible (OR 2.192, p = 0.075). The MBL mean difference (MD) between the groups was -0.053 mm (p = 0.089). There was an estimated decrease of 0.003 in OR (p = 0.284) and an increase of 0.006 mm (p = 0.036) in the MBL MD between groups for every additional month of follow-up. In conclusion, implants placed in fresh extraction sockets present higher risk of failure than implants placed in healed sites.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Dental implants inserted in fresh extraction sockets versus healed sites: A systematic review and meta-analysis
    Chrcanovic, Bruno Ramos
    Albrektsson, Tomas
    Wennerberg, Ann
    [J]. JOURNAL OF DENTISTRY, 2015, 43 (01) : 16 - 41
  • [2] Immediate implant placement into fresh extraction sockets versus delayed implants into healed sockets: A systematic review and meta-analysis
    Mello, C. C.
    Lemos, C. A. A.
    Verri, F. R.
    dos Santos, D. M.
    Goiato, M. C.
    Pellizzer, E. P.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 46 (09) : 1162 - 1177
  • [3] Marginal Bone Loss Around Dental Implants Inserted with Static Computer Assistance in Healed Sites: A Systematic Review and Meta-analysis
    Mejia, Jeison B. Carbajal
    Wakabayashi, Kazumichi
    Nakano, Tamaki
    Yatani, Hirofumi
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) : 761 - 775
  • [4] Review suggests higher failure rates for dental implants placed in fresh extraction sitesQuestion: What is the survival rate of dental implants, postoperative infection, and marginal bone loss of dental implants inserted in fresh extraction sockets compared with healed sites?
    Ismael Khouly
    Analia Veitz Keenan
    [J]. Evidence-Based Dentistry, 2015, 16 (2) : 54 - 55
  • [5] Dental implants inserted in male versus female patients: a systematic review and meta-analysis
    Chrcanovic, B. R.
    Albrektsson, T.
    Wennerberg, A.
    [J]. JOURNAL OF ORAL REHABILITATION, 2015, 42 (09) : 709 - 722
  • [6] Comparing success of immediate versus delay loading of implants in fresh sockets: a systematic review and meta-analysis
    Eini, Ebrahim
    Yousefimanesh, Hojatollah
    Ashtiani, Alireza Hashemi
    Saki-Malehi, Amal
    Olapour, Amin
    Rahim, Fakher
    [J]. ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2022, 26 (02): : 185 - 194
  • [7] Comparing success of immediate versus delay loading of implants in fresh sockets: a systematic review and meta-analysis
    Ebrahim Eini
    Hojatollah Yousefimanesh
    Alireza Hashemi Ashtiani
    Amal Saki-Malehi
    Amin Olapour
    Fakher Rahim
    [J]. Oral and Maxillofacial Surgery, 2022, 26 : 185 - 194
  • [8] EVALUATION OF THE EFFECT OF IMPLANTS PLACED IN PRESERVED SOCKETS VERSUS FRESH SOCKETS ON TISSUE PRESERVATION AND ESTHETICS: A META-ANALYSIS AND SYSTEMATIC REVIEW
    Zhou, Xin
    Yang, Jie
    Wu, Li
    Tang, Xuna
    Mou, Yongbin
    Sun, Weibin
    Hu, Qingang
    Xie, Sijing
    [J]. JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2019, 19 (04)
  • [9] CLINICAL COMPARISON OF HYDROXYAPATITE-COATED TITANIUM DENTAL IMPLANTS PLACED IN FRESH EXTRACTION SOCKETS AND HEALED SITES
    YUKNA, RA
    [J]. JOURNAL OF PERIODONTOLOGY, 1991, 62 (07) : 468 - 472
  • [10] Stability of implants placed in fresh sockets versus healed alveolar sites: Early findings
    Gehrke, Sergio Alexandre
    da Silva Neto, Ulisses Tavares
    Orlato Rossetti, Paulo Henrique
    Watinaga, Sidney Eiji
    Giro, Gabriela
    Shibli, Jamil Awad
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (05) : 577 - 582