CT colonography:: Does improved z resolution help computer-aided polyp detection?

被引:7
|
作者
Sundaram, P [1 ]
Beaulieu, CF
Paik, DS
Schraedley-Desmond, P
Napel, S
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
computer-aided detection; CT colonography; multislice CT; longitudinal resolution;
D O I
10.1118/1.1599985
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multislice helical CT offers several retrospective choices of longitudinal (z) resolution at a given detector collimation setting. We sought to determine the effect of z resolution on the performance of a computer-aided colonic polyp detector, since a human reader and a computer-aided polyp detector may have optimal performances at different z resolutions. We ran a computer-aided polyp detection algorithm on phantom data sets as well as data obtained from a single patient. All data were reconstructed at various slice thicknesses ranging from 1.25 to 10 mm. We studied the performance of the detector at various ranges of polyp sizes using free-response receiver-operating characteristic analyses. We also studied contrast-to-noise ratios (CNR) as a function of slice thickness and polyp size. For the phantom data, reducing the slice thickness from 5 to 1.25 mm improves sensitivity from 84.5% to 98.3% (all polyps), from 61.4% to 95.5% (polyps in the range [0, 5) mm) and from 97.7% to 100% (polyps in the range [5, 10) mm) at a false positive rate of 20 per data set. For polyps larger than 10 mm, there is no significant improvement in detection sensitivity when slice thickness is reduced. CNRs showed expected behavior with slice thickness and polyp size, but in all cases remained high (> 4). The results for the patient data followed similar patterns to that of the phantom case. Thus we conclude that for this detector, the optimal slice thickness is dependent upon the size of the smallest polyps to be detected. For detection of polyps 10 mm and larger, reconstruction of 5 mm sections may be sufficient. Further study is required to generalize these results to a broader population of patients scanned on different scanners. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2663 / 2674
页数:12
相关论文
共 50 条
  • [1] CT colonography: Does improved through-plane (z) resolution aid computer-aided detection (CAD) of polyps?
    Sundaram, P
    Beaulieu, CF
    Paik, DS
    Schraedley, PK
    Jeffrey, RB
    Napel, SS
    [J]. RADIOLOGY, 2002, 225 : 406 - 406
  • [2] Wavelet method for CT colonography computer-aided polyp detection
    Li, Jiang
    Van Uitert, Robert
    Yao, Jianhua
    Petrick, Nicholas
    Franaszek, Marek
    Huang, Adam
    Summers, Ronald M.
    [J]. MEDICAL PHYSICS, 2008, 35 (08) : 3527 - 3538
  • [3] Wavelet method for CT colonography computer-aided polyp detection
    Li, J.
    Franaszek, M.
    Petrick, N.
    Yao, J.
    Huang, A.
    Summers, R. M.
    [J]. 2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1316 - 1319
  • [4] Improved classifier for computer-aided polyp detection in CT Colonography by nonlinear dimensionality reduction
    Wang, Shijun
    Yao, Jianhua
    Summers, Ronald M.
    [J]. MEDICAL PHYSICS, 2008, 35 (04) : 1377 - 1386
  • [5] Benefits of centerline analysis for CT Colonography computer-aided polyp detection
    Iordanescu, G
    Summers, RM
    [J]. MEDICAL IMAGING 2003: PHYSIOLOGY AND FUNCTION: METHODS, SYSTEMS, AND APPLICATIONS, 2003, 5031 : 388 - 397
  • [6] Computer-aided detection for CT colonography
    Xu Y.-R.
    Zhao J.
    [J]. Journal of Shanghai Jiaotong University (Science), 2014, 19 (05) : 531 - 537
  • [7] Computer-Aided Detection for CT Colonography
    徐嫣然
    赵俊
    [J]. Journal of Shanghai Jiaotong University(Science), 2014, 19 (05) : 531 - 537
  • [8] CT colonography computer-aided polyp detection using topographical height map
    Yao, Jianhua
    Li, Jiang
    Summers, Ronald
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-7, 2007, : 2273 - 2276
  • [9] Improved False Positive Reduction by Novel Morphological Features for Computer-Aided Polyp Detection in CT Colonography
    Ren, Yacheng
    Ma, Jingchen
    Xiong, Junfeng
    Chen, Yi
    Lu, Lin
    Zhao, Jun
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2019, 23 (01) : 324 - 333
  • [10] CT colonography with intravenous contrast enhancement: Computer-aided polyp and mass detection
    Summers, RM
    Dempsey, J
    Campbell, SR
    Yao, J
    Franaszek, M
    Brickman, D
    Dwyer, A
    Hara, A
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 75 - 75