An integrated enzyme-linked immunosorbent assay system with an organic light-emitting diode and a charge-coupled device for fluorescence detection

被引:16
|
作者
Nakajima, Hizuru [1 ]
Okuma, Yukiko [2 ]
Morioka, Kazuhiro [1 ]
Miyake, Mayo [2 ]
Hemmi, Akihide [2 ,3 ]
Tobita, Tatsuya [2 ,4 ]
Yahiro, Masayuki [5 ]
Yokoyama, Daisuke [5 ]
Adachi, Chihaya [5 ]
Soh, Nobuaki [2 ]
Nakano, Koji [2 ]
Xue, Shuhua [1 ]
Zeng, Hulie [1 ]
Uchiyama, Katsumi [1 ]
Imato, Toshihiko [2 ]
机构
[1] Tokyo Metropolitan Univ, Dept Appl Chem, Grad Sch Urban Environm Sci, Tokyo 1920397, Japan
[2] Kyushu Univ, Dept Appl Chem, Grad Sch Engn, Nishi Ku, Fukuoka 812, Japan
[3] Mebius Adv Technol Ltd, Suginami Ku, Tokyo, Japan
[4] NTT Adv Technol Corp, Kanagawa, Japan
[5] Kyushu Univ, Ctr Future Chem, Nishi Ku, Fukuoka 812, Japan
关键词
CCD; Fluorescence detection; Immunoassay; Microfluidics; Organic light-emitting diode; THERMAL LENS MICROSCOPE; MICROCHIP ELECTROPHORESIS; NONFLUORESCENT MOLECULES; MICROFLUIDIC DEVICE; RAPID-DETERMINATION; IMMUNOGLOBULIN-A; AMINO-ACIDS; CHIP; PLATFORM; FLOW;
D O I
10.1002/jssc.201100429
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorescence detection system for a microfluidic device using an organic light-emitting diode (OLED) as the excitation light source and a charge-coupled device (CCD) as the photo detector was developed. The OLED was fabricated on a glass plate by photolithography and a vacuum deposition technique. The OLED produced a green luminescence with a peak emission at 512 nm and a half bandwidth of 55 nm. The maximum external quantum efficiency of the OLED was 7.2%. The emission intensity of the OLED at 10 mA/cm(2) was 13 mu W (1.7 mW/cm(2)). The fluorescence detection system consisted of the OLED device, two band-pass filters, a five microchannel poly(dimethylsiloxane) (PDMS) microfluidic device and a linear CCD. The fluorescence detection system was successfully used in a flow-based enzyme-linked immunosorbent assay on a PDMS microfluidic device for the rapid determination of immunoglobulin A (IgA), a marker for human stress. The detection limit (S/N = 3) for IgA was 16.5 ng/mL, and the sensitivity was sufficient for evaluating stress. Compared with the conventional 96-well microtiter plate assay, the analysis time and the amounts of reagent and sample solutions could all be reduced.
引用
收藏
页码:2906 / 2912
页数:7
相关论文
共 50 条
  • [1] Enzyme-linked immunosorbent assay by image analysis using a charge-coupled device array detector
    Sanchez, FG
    Diaz, AN
    Lovillo, J
    ANALYTICAL BIOCHEMISTRY, 1996, 239 (01) : 2 - 7
  • [2] Organic Light-Emitting Diode Based Fluorescence-Linked Immunosorbent Assay for SARS-CoV-2 Antibody Detection
    Lian, Cheng
    Young, Dan
    Randall, Richard E.
    Samuel, Ifor D. W.
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [3] Characterization of an integrated, fluorescence-detection hybrid device with photodiode and organic light-emitting diode
    Shin, Kyeong-Sik
    Kim, Young-Hwan
    Paek, Kyeong-Kap
    Park, Jung-Ho
    Yang, Eun-Gyeong
    Kim, Tae-Song
    Kang, Ji-Yoon
    Ju, Byeong-Kwon
    IEEE ELECTRON DEVICE LETTERS, 2006, 27 (09) : 746 - 748
  • [4] A miniaturized fluorescence detection system with an integrated organic light emitting diode
    Kim, JH
    Kim, YH
    Shin, KS
    Kim, BK
    Kim, YM
    Lee, YH
    Moon, SI
    Kim, TS
    Kang, JY
    Yang, EG
    Kim, SS
    Ju, BK
    Park, JO
    MEMS 2005 MIAMI: TECHNICAL DIGEST, 2005, : 806 - 809
  • [5] A Simple Oxygen Sensor Imaging Method with White Light-Emitting Diode and Color Charge-Coupled Device Camera
    Park, Jongwon
    Kim, Chang-Soo
    SENSOR LETTERS, 2011, 9 (01) : 118 - 123
  • [6] Organic Light-Emitting Diode Based Fluorescence Sensing System for DNA Detection
    Lian, Cheng
    Yoshida, Kou
    Nogues, Claude
    Samuel, Ifor D. W.
    ADVANCED MATERIALS TECHNOLOGIES, 2022, 7 (05)
  • [7] Light-emitting-diode-based light source for calibration of an intensified charge-coupled device detection system intended for galvanoluminescence measurements
    Kasalica, B. V.
    Belca, I. D.
    Stojadinovic, S. DJ.
    Zekovic, LJ. D.
    Nikolic, D.
    APPLIED SPECTROSCOPY, 2006, 60 (09) : 1090 - 1094
  • [8] Determination of picomolar equilibrium dissociation constants in solution by enzyme-linked immunosorbent assay with fluorescence detection
    High, K
    Meng, Y
    Washabaugh, MW
    Zhao, QJ
    ANALYTICAL BIOCHEMISTRY, 2005, 347 (01) : 159 - 161
  • [9] Automatic microdispenser-integrated multiplex enzyme-linked immunosorbent assay device with autonomously driven centrifugal microfluidic system
    Okamoto, Shunya
    Nagai, Moeto
    Shibata, Takayuki
    Ukita, Yoshiaki
    RSC ADVANCES, 2024, 14 (20) : 13827 - 13836
  • [10] Rapid detection of bacterial surface proteins using an enzyme-linked immunosorbent assay system
    Burkovski, A
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1997, 34 (01): : 69 - 71