Impact of FDG-PET on lung cancer delineation for radiotherapy

被引:17
|
作者
Morarji, Kavita [1 ]
Fowler, Allan [1 ]
Vinod, Shalini K. [1 ,4 ]
Shon, Ivan Ho [2 ,3 ,4 ]
Laurence, Jerome M. [5 ,6 ]
机构
[1] Univ New S Wales, Canc Therapy Ctr, Liverpool Bc, NSW 1871, Australia
[2] Univ New S Wales, Dept Nucl Med, Liverpool Bc, NSW 1871, Australia
[3] Univ New S Wales, Liverpool Hosp, PET, Liverpool Bc, NSW 1871, Australia
[4] Univ New S Wales, Fac Med, Liverpool Bc, NSW 1871, Australia
[5] Univ New S Wales, Royal Prince Alfred Hosp, Dept Surg, Liverpool Bc, NSW 1871, Australia
[6] Univ New S Wales, Dept Surg, Liverpool Bc, NSW 1871, Australia
关键词
delineation; FDG-PET; lung cancer; observer variation; radiotherapy planning; GROSS TUMOR VOLUME; CONFORMAL RADIOTHERAPY; INTEROBSERVER VARIABILITY; OBSERVER VARIATION; CT-PET; TARGET; REGISTRATION; TOMOGRAPHY; DEFINITION; FUSION;
D O I
10.1111/j.1754-9485.2012.02356.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study is to assess the impact of fused diagnostic F-18 2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) and planning FDG-PET/CT scans on voluming of lung cancer for radiotherapy. Methods: Five radiation oncologists (ROs), five radiation oncology trainees and a radiologist contoured five cases of non-small cell lung cancer. The CT alone, the diagnostic FDG-PET/CT and planning FDG-PET/CT each registered to the CT, were used to contour three volumes. The concordance index (CI) was used to compare each volume with a reference RO. Results: Although there was considerable inter-observer variability in CT contouring, there was no significant difference between mean volumes of the gross tumour volume for the RO and radiation oncology trainees using any technique. There was no increase in CI with the addition of PET/CT, either diagnostic or planning, for the RO. However, the volumes of the radiation oncology trainees showed a significant increase in CI from 65.8% with CT alone to 68.0% and 72.3% with diagnostic PET/CT and planning PET/CT, respectively (P = 0.028). Mean variation at the tumour/mediastinum interface was significantly reduced with addition of registered PET/CT. Conclusions: The concordance of RO with the reference RO did not significantly increase with use of integrated FDG PET/CT images. However, the contouring of radiation oncology trainees' became more concordant with the reference.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 50 条
  • [1] Interest of FDG-PET for lung cancer radiotherapy
    Thureau, S.
    Mezzani-Saillard, S.
    Modzelewski, R.
    Edet-Sanson, A.
    Dubray, B.
    Vera, P.
    [J]. CANCER RADIOTHERAPIE, 2011, 15 (6-7): : 504 - 508
  • [2] Potential advantages of FDG-PET radiomic feature map for target volume delineation in lung cancer radiotherapy
    Falahatpour, Zahra
    Geramifar, Parham
    Mahdavi, Seyed Rabie
    Abdollahi, Hamid
    Salimi, Yazdan
    Nikoofar, Alireza
    Ay, Mohammad Reza
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (09):
  • [3] Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer
    Bradley, J
    Thorstad, WL
    Mutic, S
    Miller, TR
    Dehdashti, F
    Siegel, BA
    Bosch, W
    Bertrand, RJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01): : 78 - 86
  • [4] Comparison of CT and FDG-PET for Target Delineation of Head and Neck Cancer in Radiotherapy Planning
    Kajitani, C.
    Asakawa, I.
    Okada, H.
    Katayama, E.
    Tamamoto, T.
    Shinkai, T.
    Uto, F.
    Maekura, T.
    Tsushima, J.
    Hasegawa, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S426 - S426
  • [5] Characteristics of FDG-PET images after stereotactic radiotherapy for lung cancer
    Matsuo, Y.
    Nakamoto, Y.
    Nagata, Y.
    Mizowaki, T.
    Takayama, K.
    Sakamoto, M.
    Norihisa, Y.
    Narita, Y.
    Togashi, K.
    Hiraoka, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S471 - S471
  • [6] Impact of FDG-PET/CT on radiotherapy volume delineation in non-small-cell lung cancer and correlation of imaging stage with pathologic findings
    Faria, Sergio L.
    Menard, Sonia
    Devic, Slobodan
    Sirois, Christian
    Souhami, Luis
    Lisbona, Robert
    Freeman, Carolyn R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1035 - 1038
  • [7] FDG-PET imaging for radiotherapy target volume definition in lung cancer
    Dubray, B.
    Thureau, S.
    Nkhali, L.
    Modzelewski, R.
    Doyeux, K.
    Ruan, S.
    Vera, P.
    [J]. IRBM, 2014, 35 (01) : 41 - 45
  • [8] Assessment of the Impact of FDG-PET on Lung Cancer Treatment.
    Ashish, A.
    Menzes, B.
    Sheppard, S.
    Walker, P. P.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [9] Cavitary lung cancer and FDG-PET
    Triponez, F
    de Perrot, M
    Orrit, J
    Robert, J
    Spiliopoulos, A
    [J]. ANNALES DE CHIRURGIE, 2002, 127 (05): : 403 - 404
  • [10] Comparison of different methods of FDG-PET target volume delineation in the radiotherapy of head and neck cancer
    Greco, C.
    Nehmeh, S.
    Shoder, H.
    Gonen, M.
    Raphael, B.
    Stambuk, H.
    Humm, J.
    Lee, N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S422 - S422