Magnetic field sensing performance of centimeter-scale resonator with optimized structure

被引:1
|
作者
Yu Chang-Qiu [1 ]
Ma Shi-Chang [1 ]
Chen Zhi-Yuan [1 ]
Xiang Chen-Chen [1 ]
Li Hai [1 ]
Zhou Tie-Jun [1 ]
机构
[1] Hangzhou Dianzi Univ, Informat Engn Sch, Hangzhou 310018, Peoples R China
基金
中国国家自然科学基金;
关键词
magnetic field sensing; optical resonator; whispering gallery mode; WHISPERING-GALLERY MODES;
D O I
10.7498/aps.70.20210247
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Applications of magnetometers are affected mainly by their sensitivities and detection bandwidths. Till now, the applications of the centimeter-scale optomechanical magnetometer have been still limited by those two factors. In order to improve its sensing performance in a low frequency regime of the alternating current (AC) magnetic field sensor based on centimeter-scale whispering gallery mode resonator, we design a new centimeterscale crystalline whispering gallery mode resonator which has different relative distributions of the magnetostrictive material (Terfenol-D) and the optical material (CaF2) from the unoptimized centimeter-scale whispering gallery mode resonator. Experimental results show that this new resonator is able to detect the AC magnetic field ranging from 6 Hz to 1 MHz, and a peak sensitivity of 530 pT.Hz(-1/2) at 123.8 kHz is achieved without DC bias field in a magnetically unshielded non-cryogenic environment. On condition that the optical quality factor is at the same level of 10(8) and there is no DC bias magnetic field, the best sensitivity of the optimized resonator is 11 times higher than that of the unoptimized resonator, and the corresponding detection frequency band is expanded by 1.67 times, switching from the frequency band of 10 Hz-600 kHz to 6 Hz-1 MHz. Besides, the device only needs 100 mu W light intensity to operate, which offers us a low optical power consumption magnetometer. Within the detection frequency band, the proposed magnetometer can detect both a single frequency alternating magnetic field signal and an alternating magnetic field signal covering a certain frequency range. It can detect 50 or 60 Hz alternating magnetic field signal generated by current in the wire so that the working status of the power system can be monitored. If the sensing performance is further improved, it may be able to detect the magnetic field signal at frequency in a range of 1 kHz-10 MHz generated by the partial discharge current and the extremely low frequency human body magnetic field signal located in a frequency band of [10 mHz-1 kHz]. Further improvement in sensing performance is possible through optimizing the system noise and the magnetic field response capability of the device, which might allow the device to possess the applications in the fields of power system fault monitoring and medical diagnosis.
引用
收藏
页数:7
相关论文
共 36 条
  • [1] Photonic Electric Field Sensor Based on Polymeric Microspheres
    Ali, Amir R.
    Ioppolo, Tindaro
    Oetuegen, Volkan
    Christensen, Marc
    MacFarlane, Duncan
    [J]. JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2014, 52 (03) : 276 - 279
  • [2] Measuring nanomechanical motion with an imprecision below the standard quantum limit
    Anetsberger, G.
    Gavartin, E.
    Arcizet, O.
    Unterreithmeier, Q. P.
    Weig, E. M.
    Gorodetsky, M. L.
    Kotthaus, J. P.
    Kippenberg, T. J.
    [J]. PHYSICAL REVIEW A, 2010, 82 (06):
  • [3] Moving magnetoencephalography towards real-world applications with a wearable system
    Boto, Elena
    Holmes, Niall
    Leggett, James
    Roberts, Gillian
    Shah, Vishal
    Meyer, Sofie S.
    Munoz, Leonardo Duque
    Mullinger, Karen J.
    Tierney, Tim M.
    Bestmann, Sven
    Barnes, Gareth R.
    Bowtell, Richard
    Brookes, Matthew J.
    [J]. NATURE, 2018, 555 (7698) : 657 - +
  • [4] Engdahl G., 2000, HDB GIANT MAGNETOSTR, V1st, P257
  • [5] Model of a Microtoroidal Magnetometer
    Forstner, S.
    Knittel, J.
    Rubinsztein-Dunlop, H.
    Bowen, W. P.
    [J]. OPTICAL SENSING AND DETECTION II, 2012, 8439
  • [6] Cavity Optomechanical Magnetometer
    Forstner, S.
    Prams, S.
    Knittel, J.
    van Ooijen, E. D.
    Swaim, J. D.
    Harris, G. I.
    Szorkovszky, A.
    Bowen, W. P.
    Rubinsztein-Dunlop, H.
    [J]. PHYSICAL REVIEW LETTERS, 2012, 108 (12)
  • [7] Ultrasensitive Optomechanical Magnetometry
    Forstner, Stefan
    Sheridan, Eoin
    Knittel, Joachim
    Humphreys, Christopher L.
    Brawley, George A.
    Rubinsztein-Dunlop, Halina
    Bowen, Warwick P.
    [J]. ADVANCED MATERIALS, 2014, 26 (36) : 6348 - 6353
  • [8] Grosz A, 2017, HIGH SENSITIVITY MAG, P140
  • [9] Minimum Requirements for Feedback Enhanced Force Sensing
    Harris, Glen I.
    McAuslan, David L.
    Stace, Thomas M.
    Doherty, Andrew C.
    Bowen, Warwick P.
    [J]. PHYSICAL REVIEW LETTERS, 2013, 111 (10)
  • [10] Digital Compensation of Rogowski Coil's Output Voltage
    Hemmati, Esmaeil
    Shahrtash, S. Mohammad
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (01) : 71 - 82