Optical parametric oscillator-based trace detection of gases in the mid-infrared region using phase-fluctuation optical heterodyne spectroscopy

被引:0
|
作者
Thomas, Jack W. [1 ]
Polak, Adam [1 ]
Bonner, Gerald M. [1 ]
Enderle, Sandra [1 ]
Dunn, Malcolm H. [2 ]
Stothard, David J. M. [1 ]
机构
[1] Fraunhofer Ctr Appl Photon, Technol & Innovat Ctr, 99 George St, Glasgow G1 1RD, Lanark, Scotland
[2] Univ St Andrews, Sch Phys & Astron, St Andrews KY16 9SS, Fife, Scotland
关键词
PFLOH spectroscopy; photo-thermal; optical parametric oscillator; Mach-Zehnder interferometer; CONTINUOUS-WAVE; DIODE-LASER; LIGHT;
D O I
10.1117/12.2305736
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Laser absorption spectroscopy utilizes a tunable infrared source, providing the necessary selectivity, to detect the characteristic fingerprint spectral absorption of an abundant gas. In a simple embodiment such as single-pass absorption, sensitivity is limited as attenuation becomes minuscule for trace level concentrations; a problem exacerbated in the mid-infrared region due to significant detector noise. Sensitivity can be improved by increasing interaction between the optical field and molecular ensemble with methods such as a multiple-pass Herriot cell or resonant cavity ring-down spectroscopy but these techniques have a substantial overhead in instrumentation. An alternative approach to this problem is Phase Fluctuation Optical Heterodyne (PFLOH) spectroscopy. Here, interferometric effects are used to detect the minute heating of the sample gas when incident laser light of the appropriate wavelength is absorbed. More specifically, by placing the absorption chamber within one arm of a Mach-Zehnder interferometer, heat-induced changes in the optical path length can be detected with great sensitivity through the resulting fringe modulation. A secondary benefit is that although excitation occurs in the infrared, its effects can be detected using visible lasers and silicon detectors, thereby obviating the need for cooled, infrared detectors. We will present our results used to detect ethane using absorption in the 3.33-3.37 mu m region. The Mach-Zehnder interferometer used a Helium Neon laser for the probe laser, and a broadly tunable Optical Parametric Oscillator (OPO) for spectroscopic excitation. We have demonstrated detection levels at parts per billion with further sensitivity possible by implementing several identified improvements.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Quantum cascade laser-based trace detection of gases in the deep-infrared region using phase-fluctuation optical heterodyne spectroscopy
    Thomas, Jack
    Polak, Adam
    Stothard, David J. M.
    [J]. CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XX, 2019, 11010
  • [3] Amplification assisted optical parametric oscillator in the mid-infrared region
    Y. H. Liu
    X. J. Lv
    Z. D. Xie
    X. P. Hu
    Y. Yuan
    J. Lu
    L. N. Zhao
    G. Zhao
    S. N. Zhu
    [J]. Applied Physics B, 2012, 106 : 267 - 270
  • [4] Amplification assisted optical parametric oscillator in the mid-infrared region
    Liu, Y. H.
    Lv, X. J.
    Xie, Z. D.
    Hu, X. P.
    Yuan, Y.
    Lu, J.
    Zhao, L. N.
    Zhao, G.
    Zhu, S. N.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 106 (02): : 267 - 270
  • [5] PHASE FLUCTUATION OPTICAL HETERODYNE SPECTROSCOPY OF GASES
    DAVIS, CC
    PETUCHOWSKI, SJ
    [J]. APPLIED OPTICS, 1981, 20 (14): : 2539 - 2554
  • [6] Progress of mid-infrared optical parametric oscillator
    Li Chong
    Xie Ji-jiang
    Pan Qi-kun
    Chen Fei
    He Yang
    Zhang Kuo
    [J]. CHINESE OPTICS, 2016, 9 (06): : 615 - 624
  • [7] Mid-infrared dual-comb spectroscopy with an optical parametric oscillator
    Zhang, Zhaowei
    Gardiner, Tom
    Reid, Derryck T.
    [J]. OPTICS LETTERS, 2013, 38 (16) : 3148 - 3150
  • [8] Optical vortex pumped mid-infrared optical parametric oscillator
    Miyamoto, Katsuhiko
    Miyagi, Sachio
    Yamada, Masaki
    Furuki, Kenji
    Aoki, Nobuyuki
    Okida, Masahito
    Omatsu, Takashige
    [J]. OPTICS EXPRESS, 2011, 19 (13): : 12220 - 12226
  • [9] Continuous-wave, singly resonant parametric oscillator-based mid-infrared optical vortex source
    Aadhi, A.
    Sharma, Varun
    Singh, R. P.
    Samanta, G. K.
    [J]. OPTICS LETTERS, 2017, 42 (18) : 3674 - 3677
  • [10] Doppler-broadened mid-infrared noise-immune cavity-enhanced optical heterodyne molecular spectrometry based on an optical parametric oscillator for trace gas detection
    Silander, Isak
    Hausmaninger, Thomas
    Ma, Weiguang
    Harren, Frans J. M.
    Axner, Ove
    [J]. OPTICS LETTERS, 2015, 40 (04) : 439 - 442