Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye

被引:60
|
作者
Carvalho, LA
机构
[1] Univ Sao Paulo, IFSC, Grp Opt, Sao Paulo, Brazil
[2] Univ Fed Sao Paulo, Escola Paulista Med, Dept Oftalmol, Sao Paulo, Brazil
关键词
D O I
10.1167/iovs.04-1222
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Zernike polynomials have been successfully used for approximately 70 years in many different fields of optics. Nevertheless, there are some recent discussions regarding the precision and accuracy of these polynomials when applied to surfaces such as the human cornea. The main objective of this work was to investigate the absolute accuracy of Zernike polynomials of different orders when fitting several types of theoretical corneal and wave-front surface data. METHODS. A set of synthetic surfaces resembling several common corneal anomalies was sampled by using cylindrical coordinates to simulate the height output files of commercial video-keratography systems. The same surfaces were used to compute the optical path difference (wave-front [WF] error), by using a simple ray-tracing procedure. Corneal surface and WF error was fit by using a least-squares algorithm and Zernike polynomials of different orders, varying from 1 to 36 OSA-VSIA convention terms. RESULTS. The root mean square error (RMSE) ranged - from the most symmetric corneal surface (spherical shape) through the most complex shape (after radial keratotomy [RK]) for both the optical path difference and the surface elevation for 1 through 36 Zernike terms - from 421.4 to 0.8 mu m and 421.4 to 8.2 mu m, respectively. The mean RMSE for the maximum Zernike terms for both surfaces was 4.5 mu m. CONCLUSIONS. These results suggest that, for surfaces such as that present after RK, in keratoconus, or after keratoplasty, even more than 36 terms may be necessary to obtain minimum accuracy requirements. The author suggests that the number of Zernike polynomials should not be a global fixed conventional or generally accepted value but rather a number based on specific surface properties and desired accuracy.
引用
收藏
页码:1915 / 1926
页数:12
相关论文
共 50 条
  • [1] On the absolute accuracy of Zernike Polynomials to characterize the corneal surface and the optical aberrations of the human eye
    Carvalho, LA
    [J]. Saratov Fall Meeting 2004: Coherent Optics of Ordered and Random Media V, 2005, 5772 : 181 - 192
  • [2] ZERNIKE POLYNOMIALS AND OPTICAL ABERRATIONS
    MAHAJAN, VN
    [J]. APPLIED OPTICS, 1995, 34 (34): : 8060 - 8062
  • [3] Eye aberrations analysis with Zernike polynomials
    Molebny, VV
    Chyzh, IH
    Sokurenko, VM
    Pallikaris, IG
    Naoumidis, LP
    [J]. OPHTHALMIC TECHNOLOGIES VIII, PROCEEDINGS OF, 1998, 3246 : 228 - 237
  • [4] Simulation of Corneal Aberrations by using Zernike Polynomials
    Koyuncu, Baki
    Kocabasoglu, Pinar
    [J]. SENSORS, SIGNALS, VISUALIZATION, IMAGING, SIMULATION AND MATERIALS, 2009, : 174 - 178
  • [5] Comparison of accuracy of zernike polynomials and Fourier series in corneal surface representation
    Alchagirov, A
    Klyce, D
    Smolek, MK
    Karon, MD
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [7] ZERNIKE ANNULAR POLYNOMIALS AND OPTICAL ABERRATIONS OF SYSTEMS WITH ANNULAR PUPILS
    MAHAJAN, VN
    [J]. APPLIED OPTICS, 1994, 33 (34): : 8125 - 8127
  • [8] Aberrations in holographic array optical tweezers corrected with Zernike polynomials
    Liu Wei-Wei
    Ren Yu-Xuan
    Gao Hong-Fang
    Sun Qing
    Wang Zi-Qiang
    Li Yin-Mei
    [J]. ACTA PHYSICA SINICA, 2012, 61 (18)
  • [9] ZERNIKE CIRCLE POLYNOMIALS AND OPTICAL ABERRATIONS OF SYSTEMS WITH CIRCULAR PUPILS
    MAHAJAN, VN
    [J]. APPLIED OPTICS, 1994, 33 (34): : 8121 - 8124
  • [10] ZERNIKE-GAUSS POLYNOMIALS AND OPTICAL ABERRATIONS OF SYSTEMS WITH GAUSSIAN PUPILS
    MAHAJAN, VN
    [J]. APPLIED OPTICS, 1995, 34 (34): : 8057 - 8059