A clinical study on the tip localization of peripherally inserted central catheter (PICC) guided by intracavitary electrocardiography in newborns: a randomised trial

被引:8
|
作者
Zhu, Li-Bo [1 ]
Liu, Ling [1 ]
Zhang, Tie-Song [1 ]
Zheng, Yu-Ting [1 ]
Lu, Chun-Yan [1 ]
Lu, Kun [1 ]
Zhang, Shu-Xian [1 ]
Duan, Liu-Yan [1 ]
Yang, Mei-Lin [1 ]
机构
[1] Kunming Childrens Hosp, Dept Neonatol, 288 Qianxing Rd, Kunming 650228, Yunnan, Peoples R China
关键词
Intra-atrial electrocardiogram; characteristic P wave; peripherally inserted central catheter (PICC); newborn; intensive care unit; CENTRAL VENOUS CATHETERS; ECG METHOD; SAFETY; ACCURACY; GUIDANCE; POSITION;
D O I
10.21037/tp-20-370
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: The present study aimed to investigate the P-wave changes in intracavitary electrocardiography (IC-ECG) during catheterization with a peripherally inserted central catheter (PICC) in order to provide guidance for the accurate localization of the tip of the PICC. Methods: A total of 106 newborns who needed a PICC were randomly divided into two groups-a study group and a control group-using a random number table, with 53 cases in each group. In the study group, the ECG monitor was connected after the successful puncture and insertion of the PICC into the right sternoclavicular joint, and the position of the catheter tip was determined according to the P-wave changes on the IC-ECG. Localization X-rays were taken at the same time. In the control group, after the successful routine puncture and insertion of the PICC into the location to a predetermined length, localization X-rays were taken. The accuracy, procedure duration, and cost of the two localization methods were evaluated. Results: The accuracy of the localization in the study group was 92.5%, but the difference was not significant when compared with the control group (P>0.05). The duration of the procedure in the study group was 5.12 +/- 1.57 minutes, and the cost was 7.12 +/- 0.56 yuan, both of which were significantly different when compared with the control group (P<0.05). Conclusions: P-wave changes during IC-ECG have high accuracy in determining the location of the tip of the PICC. It is also a simple method and has certain clinical application value.
引用
收藏
页码:2409 / +
页数:10
相关论文
共 50 条
  • [1] Peripherally Inserted Central Catheter: it is really time for intracavitary electrocardiography
    Bontini, S.
    Mordenti, P.
    Oleari, F.
    Carini, S.
    Castellani, S.
    Gozzo, C.
    Grassi, O.
    Muroni, M.
    Cordani, M. R.
    Cremona, G.
    Cavanna, L.
    [J]. ANNALS OF ONCOLOGY, 2016, 27
  • [2] Study on the Safety and Accuracy of Intracavitary Electrocardiography and Ultrasound in the Peripherally Inserted Central Venous Catheter tip positioning of Breast Cancer Patients
    Xu, Yan Fei
    Xu, Xia Fei
    Song, Kun
    Qiu, C.
    Zhang, Xiao Li
    Mam, Di Li Nu Er-Re He
    Huang, S.
    [J]. INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 83 : 6 - 11
  • [3] Intracavitary electrocardiography for femorally inserted central catheter tip location in adult patients
    Duan, YingFang
    Hu, XiaoYan
    Zhu, YuXin
    Zhao, Xi
    Yin, XinXin
    Zhang, HaiMan
    Wang, Yu
    [J]. ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2022, 27 (02)
  • [4] Point-of-care ultrasound (POCUS) for tip localization of neonatal peripherally inserted central catheter (PICC): A prospective study
    Lin, Shu-Yu
    Chiang, Ming-Chou
    Wu, Wei-Hung
    Wu, I-Hsyuan
    Lai, Mei-Yin
    Chu, Shih-Ming
    Lien, Reyin
    Hsu, Kai-Hsiang
    [J]. PEDIATRICS AND NEONATOLOGY, 2024, 65 (04): : 375 - 380
  • [5] An accuracy study of the Intracavitary Electrocardiogram (IC-ECG) guided peripherally inserted central catheter tip placement among neonates
    Zhou, Lian-juan
    Xu, Hong-zhen
    Xu, Mei-fang
    Hu, Yan
    Lou, Xiao-fang
    [J]. OPEN MEDICINE, 2017, 12 (01): : 125 - 130
  • [6] Ultrasound Guided Confirmation of Tip of Peripherally Inserted Central Catheter in Neonates
    Singh, Surjeet
    Venkatesh, H. A.
    Swamy, Ravi
    Nagesh, N. Karthik
    [J]. INDIAN PEDIATRICS, 2020, 57 (09) : 858 - 859
  • [7] Effectiveness of Intracavitary Electrocardiogram Guidance in Peripherally Inserted Central Catheter Tip Placement in Neonates
    Zhou, Lianjuan
    Xu, Hongzhen
    Liang, Jianfeng
    Xu, Meifang
    Yu, Jun
    [J]. JOURNAL OF PERINATAL & NEONATAL NURSING, 2017, 31 (04) : 326 - 331
  • [8] Ultrasound Guided Confirmation of Tip of Peripherally Inserted Central Catheter in Neonates
    Surjeet Singh
    H. A. Venkatesh
    Ravi Swamy
    N. Karthik Nagesh
    [J]. Indian Pediatrics, 2020, 57 (9) : 858 - 859
  • [9] Intracavitary electrocardiogram (IC-ECG) guidance for peripherally inserted central catheter (PICC) placement
    Santacruz, Elisa
    Mateo-Lobo, Raquel
    Vega-Pinero, Belen
    Riveiro, Javier
    Lomba, Gema
    Sabido, Raquel
    Carabana, Fatima
    Botella-Carretero, Jose I.
    [J]. NUTRICION HOSPITALARIA, 2018, 35 (05) : 1005 - 1008
  • [10] Establishing an ultrasound guided peripherally inserted central catheter (PICC) insertion service
    Parkinson, R
    Gandhi, M
    Harper, J
    Archibald, C
    [J]. CLINICAL RADIOLOGY, 1998, 53 (01) : 33 - 36