Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?

被引:122
|
作者
Rowlands, Alex V. [1 ,2 ,3 ]
Mirkes, Evgeny M. [4 ]
Yates, Tom [1 ,2 ]
Clemes, Stacey [5 ]
Davies, Melanie [1 ,2 ]
Khunti, Kamlesh [1 ,2 ,6 ]
Edwardson, Charlotte L. [1 ,2 ]
机构
[1] Univ Leicester, Leicester Gen Hosp, Diabet Res Ctr, Leicester LE5 4PW, Leics, England
[2] NIHR Leicester Biomed Res Ctr, Leicester, Leics, England
[3] Univ South Australia, Alliance Res Exercise Nutr & Act ARENA, Div Hlth Sci, Sansom Inst Hlth Res, Adelaide, SA, Australia
[4] Univ Leicester, Dept Math, Leicester, Leics, England
[5] Univ Loughborough, Sch Sport Exercise & Hlth Sci, Loughborough, Leics, England
[6] Leicester Gen Hosp, NIHR Collaborat Leadership Appl Hlth Res & Care E, Leicester, Leics, England
来源
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE | 2018年 / 50卷 / 02期
关键词
ACTIGRAPH; AXIVITY; GENEACTIV; GGIR; GT9X; LINK; OLDER-ADULTS; COHORT; WRIST; COMPARABILITY; ACCELERATION; CONSORTIUM; MORTALITY; VALIDITY;
D O I
10.1249/MSS.0000000000001435
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose Accelerometers are increasingly being used to assess physical activity in large-scale surveys. Establishing whether key physical activity outcomes can be considered equivalent between three widely used accelerometer brands would be a significant step toward capitalizing on the increasing availability of accelerometry data for epidemiological research. Methods Twenty participants wore a GENEActiv, an Axivity AX3, and an ActiGraph GT9X on their nondominant wrist and were observed for 2 h in a simulated living space. Participants undertook a series of seated and upright light/active behaviors at their own pace. All accelerometer data were processed identically using open-source software (GGIR) to generate physical activity outcomes (including average dynamic acceleration (ACC) and time within intensity cut points). Data were analyzed using pairwise 95% equivalence tests (10% equivalence zone), intraclass correlation coefficients (ICC) and limits of agreement. Results The GENEActiv and Axivity could be considered equivalent for ACC (ICC = 0.95, 95% confidence interval (CI), 0.87-0.98), but ACC measured by the ActiGraph was approximately 10% lower (GENEActiv/ActiGraph: ICC = 0.86; 95% CI, 0.56-0.95; Axivity/ActiGraph: ICC = 0.82; 95% CI, 0.50-0.94). For time spent within intensity cut points, all three accelerometers could be considered equivalent to each other for more than 85% of outcomes (ICC 0.69, lower 95% CI 0.36), with the GENEActiv and Axivity equivalent for 100% of outcomes (ICC 0.95, lower 95% CI 0.86). Conclusions GENEActiv and Axivity data processed in GGIR are largely equivalent. If GENEActiv or Axivity is compared with the ActiGraph, time spent within intensity cut points has good agreement. These findings can be used to inform selection of appropriate outcomes if outputs from these accelerometer brands are compared.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 50 条
  • [1] Reproducibility of Accelerometer-Assessed Physical Activity and Sedentary Time
    Keadle, Sarah Kozey
    Shiroma, Eric J.
    Kamada, Masamitsu
    Matthews, Charles E.
    Harris, Tamara B.
    Lee, I-Min
    AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2017, 52 (04) : 541 - 548
  • [2] Accelerometer-Assessed Physical Activity and Diabetic Retinopathy in the United States
    Loprinzi, Paul D.
    Brodowicz, Gary R.
    Sengupta, Sabyasachi
    Solomon, Sharon D.
    Ramulu, Pradeep Y.
    JAMA OPHTHALMOLOGY, 2014, 132 (08) : 1017 - 1019
  • [3] Accelerometer-Assessed Physical Activity and Sedentary Time in Youth With Disabilities
    Lobenius-Palmer, Karin
    Sjoqvist, Birgitta
    Hurtig-Wennlof, Anita
    Lundqvist, Lars-Olov
    ADAPTED PHYSICAL ACTIVITY QUARTERLY, 2018, 35 (01) : 1 - 19
  • [4] Accelerometer-assessed physical activity and depression among US adults with diabetes
    Loprinzi, Paul D.
    Franz, Chelsey
    Hager, Kathy K.
    MENTAL HEALTH AND PHYSICAL ACTIVITY, 2013, 6 (02) : 79 - 82
  • [5] Accelerometer-assessed physical activity, inactivity and sleep in individuals with hypertrophic cardiomyopathy
    Charman, S. J.
    Blain, A. P.
    Okwose, N. C.
    Fuller, A. S.
    Alyahya, A. I.
    Hallsworth, K.
    Eggett, C.
    Luke, P.
    Bailey, K.
    Macgowan, G. A.
    Jakovljevic, D. G.
    EUROPEAN JOURNAL OF HEART FAILURE, 2023, 25 : 373 - 373
  • [6] Effect of Playground Interventions on Accelerometer-Assessed Physical Activity in Pediatric Populations
    Strehli, Ildiko
    Kwon, Sunku
    Pfledderer, Christopher
    Burns, Ryan D.
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2020, 91 : A62 - A62
  • [7] Accelerometer-Assessed Physical Activity And Sedentary Time Profiles Of Kidney Transplant Recipients
    Vallance, Jeff K.
    Johnson, Steven T.
    Wen, Kevin
    Lam, Ngan N.
    Thompson, Stephanie
    Boyle, Terry
    Shojai, Soroush
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 715 - 715
  • [8] Goal Conflict and Goal Facilitation as Predictors of Daily Accelerometer-Assessed Physical Activity
    Presseau, Justin
    Tait, Richard I.
    Johnston, Derek W.
    Francis, Jill J.
    Sniehotta, Falko F.
    HEALTH PSYCHOLOGY, 2013, 32 (12) : 1179 - 1187
  • [9] Examining The "Weekend Warrior" And Mortality Using Accelerometer-assessed Physical Activity In NHANES
    Shiroma, Eric J.
    Lee, I-Min
    Schepps, Mitchell A.
    Kamada, Masamitsu
    Meirelles, Osorio
    Harris, Tamara B.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 847 - 847
  • [10] Comparison of Self-Reported and Accelerometer-Assessed Physical Activity in Older Women
    Shiroma, Eric J.
    Cook, Nancy R.
    Manson, Joann E.
    Buring, Julie E.
    Rimm, Eric B.
    Lee, I-Min
    PLOS ONE, 2015, 10 (12):