Fluid-solid interaction simulation of flow and stress pattern in thoracoabdominal aneurysms: A patient-specific study

被引:58
|
作者
Borghi, A. [1 ]
Wood, N. B. [1 ]
Mohiaddin, R. H. [2 ]
Xu, X. Y. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn, London SW72 AZ, England
[2] Royal Brompton Harefield NHS Trust, London, England
关键词
thoracoabdominal aneurysm; magnetic resonance imaging; fluid-solid interaction; intra-luminal thrombus;
D O I
10.1016/j.jfluidstructs.2007.08.005
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Thoracoabdominal aneurysm (TA) is a pathology that involves the enlargement of the aortic diameter in the inferior descending thoracic aorta and has risk factors including aortic dissection, aortitis or connective tissue disorders. Abnormal flow patterns and haemodynamic stress on the diseased aortic wall are thought to play an important role in the development of this pathology and the internal wall stress has proved to be more reliable as a predictor of rupture than the maximum diameter for abdominal aortic aneurysms; but this assumption has not been validated yet for aneurysms involving the thoracic aorta. In the present study, three patients with TAs of different maximum diameters were scanned using magnetic resonance imaging (MRI) techniques. Realistic models of the aneurysms were reconstructed from the in vivo MRI data acquired from the patients, and subject-specific flow conditions were applied as boundary conditions. The wall and thrombus were modelled as hyperelastic materials and their properties were derived from the literature. A normal descending aorta was also simulated to provide data for comparison. Fully coupled fluid-solid interaction (FSI) simulations as well as solid static simulations were performed using ADINA 8.2. The results show that the wall stress distribution and its magnitude are strongly dependent on the 3-D shape of the aneurysm and the distribution of thrombus. Maximum wall stresses in all TA models are higher than in the normal aorta, and values of maximum wall stress are not directly related to the maximum aneurysm diameter. Comparisons between the FSI and solid static simulation results showed no significant difference in maximum wall stress, supporting those previous studies which found that FSI simulations were not necessary for wall stress prediction. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:270 / 280
页数:11
相关论文
共 50 条
  • [1] Fluid-solid interaction simulation of flow and stress pattern in thoracoabdominal aneurysms: A patient specific study
    Borghi, Alessandro
    Wood, Nigel B.
    Mohiaddin, Raad H.
    Xu, X. Yun
    [J]. PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE VOL 9, 2007, : 671 - 675
  • [2] Blood flow dynamics and fluid-structure interaction in patient-specific bifurcating cerebral aneurysms
    Valencia, Alvaro
    Ledermann, Darren
    Rivera, Rodrigo
    Bravo, Eduardo
    Galvez, Marcelo
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2008, 58 (10) : 1081 - 1100
  • [3] Fluid-structure interaction simulation for studying hemodynamics and rupture risk of patient-specific intracranial aneurysms
    Ruan, Chang
    Yu, Qi
    Hou, Jingyuan
    Ou, Xinying
    Liu, Yi
    Chen, Yu
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2023, 25 (03) : 73 - 85
  • [4] A Comparative Study Based on Patient-Specific Fluid-Structure Interaction Modeling of Cerebral Aneurysms
    Takizawa, Kenji
    Brummer, Tyler
    Tezduyar, Tayfun E.
    Chen, Peng R.
    [J]. JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2012, 79 (01):
  • [5] Numerical Study of Fluid-Solid Interaction in Rotational Extrusion Flow
    Zhou, Yanan
    He, Qiaolin
    Nie, Min
    Yang, Changhua
    [J]. EAST ASIAN JOURNAL ON APPLIED MATHEMATICS, 2024, 14 (01) : 24 - 46
  • [6] Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models
    James H Leung
    Andrew R Wright
    Nick Cheshire
    Jeremy Crane
    Simon A Thom
    Alun D Hughes
    Yun Xu
    [J]. BioMedical Engineering OnLine, 5
  • [7] Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models
    Leung, James H.
    Wright, Andrew R.
    Cheshire, Nick
    Crane, Jeremy
    Thom, Simon A.
    Hughes, Alun D.
    Xu, Yun
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
  • [8] Fluid Structure Interaction of Patient Specific Internal Carotid Aneurysms: A Comparison with Solid Stress Models
    Fu, Wenyu
    Qiao, Aike
    [J]. 6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 422 - +
  • [9] Patient-specific arterial fluid-structure interaction modeling of cerebral aneurysms
    Takizawa, Kenji
    Moorman, Creighton
    Wright, Samuel
    Purdue, John
    McPhail, Travis
    Chen, Peng R.
    Warren, Joe
    Tezduyar, Tayfun E.
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2011, 65 (1-3) : 308 - 323
  • [10] Multiscale Numerical Simulation of Fluid-Solid Interaction
    Inoue, Yohei
    Tanaka, Junji
    Kobayashi, Ryo
    Ogata, Shuji
    Gotoh, Toshiyuki
    [J]. MATERIALS TRANSACTIONS, 2008, 49 (11) : 2550 - 2558