Extraction of thermal parameters of microbolometer infrared detectors using electrical measurement

被引:4
|
作者
Karunasiri, G [1 ]
Gu, X [1 ]
Chen, G [1 ]
Sridhar, U [1 ]
机构
[1] Natl Univ Singapore, Dept Elect Engn, Ctr Optoelect, Singapore 119260, Singapore
关键词
microbolometers; thermal parameters; silicon; self-heating; micromachining; infrared;
D O I
10.1117/12.328067
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance of microbolometer infrared sensors is typically characterized by its thermal time constant, heat capacitance, and thermal conductance. Therefore, the determination of these parameters accurately and efficiently is of considerable interest for the design and operation of microbolometer infrared sensors. Usually, the thermal time constant is obtained by measuring the frequency response of microbolometers under infrared excitation and the thermal conductance and capacity are extracted using electrical measurement. in this paper, a technique is described to extract all three parameters using a single electrical measurement. In the measurement, we have employed a Wheatstone Bridge consisting of a bolometer and three reference resistors. The resistance of the bolometer changes as a result of self-heating under an external bias which in rum generates an output voltage across the Bridge. The time dependence of the output voltage was used to extract thermal parameters of the bolometer. We believe this technique is useful in determining the thermal parameters of microbolometer based sensors.
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [1] FAR-INFRARED MICROBOLOMETER DETECTORS
    NEIKIRK, DP
    LAM, WW
    RUTLEDGE, DB
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1984, 5 (03): : 245 - 278
  • [2] Measurement rates of static single-mirror Fourier transform infrared spectrometers using microbolometer detectors
    Schardt, Michael
    Rauscher, Markus S.
    Murr, Patrik J.
    Und, Anton J. Tremmel
    Koch, Alexander W.
    TM-TECHNISCHES MESSEN, 2017, 84 (03) : 149 - 156
  • [3] Effect of operating temperature on electrical and thermal properties of microbolometer infrared sensors
    Karunasiri, G
    Ramakrishna, MVS
    Neuzil, P
    SENSORS AND MATERIALS, 2003, 15 (03) : 147 - 154
  • [4] Extraction of electrical parameters of HPGe segmented detectors
    Pullia, A
    Isocrate, R
    Venturelli, R
    Bazzacco, D
    Bassini, R
    Boiano, C
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 543 - 545
  • [5] Determination of Thermal Parameters of Vanadium Oxide Uncooled Microbolometer Infrared Detector
    R. T. Rajendra Kumar
    B. Karunagaran
    D. Mangalaraj
    Sa. K. Narayandass
    P. Manoravi
    M. Joseph
    Vishnu Gopal
    R. K. Madaria
    J. P. Singh
    International Journal of Infrared and Millimeter Waves, 2003, 24 : 327 - 334
  • [6] Determination of thermal parameters of vanadium oxide uncooled microbolometer infrared detector
    Kumar, RTR
    Karunagaran, B
    Mangalaraj, D
    Narayandass, SK
    Manoravi, P
    Joseph, M
    Gopal, V
    Madaria, RK
    Singh, JP
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2003, 24 (03): : 327 - 334
  • [7] Low-Cost Microbolometer Type Infrared Detectors
    Yu, Le
    Guo, Yaozu
    Zhu, Haoyu
    Luo, Mingcheng
    Han, Ping
    Ji, Xiaoli
    MICROMACHINES, 2020, 11 (09)
  • [8] Performance of titanium and amorphous germanium microbolometer infrared detectors
    Ramakrishna, MVS
    Karunasiri, G
    Sridhar, U
    Chen, G
    SELECTED PAPERS FROM PHOTONICS INDIA '98, 1999, 3666 : 415 - 420
  • [10] Determination of thermal parameters of microbolometers using a single electrical measurement
    Gu, X
    Karunasiri, G
    Chen, G
    Sridhar, U
    Xu, B
    APPLIED PHYSICS LETTERS, 1998, 72 (15) : 1881 - 1883