Plasma Response to Amplitude Modulation of the Microwave Power on a 14 GHz Electron Cyclotron Resonance Ion Source

被引:0
|
作者
Neben, Derek [1 ]
Tarvainen, Olli [2 ]
Kronholm, Risto [2 ]
Koivisto, Hannu [2 ]
Kalvas, Taneli [2 ]
Machicoane, Guillaume [1 ]
Leitner, Daniela [1 ,3 ]
机构
[1] Michigan State Univ, E Lansing, MI 48824 USA
[2] Univ Jyvaskyla, Jyvaskyla, Finland
[3] Lawrence Berkley Natl Lab, Berkeley, CA USA
基金
芬兰科学院; 美国国家科学基金会;
关键词
D O I
10.1063/1.5053286
中图分类号
O59 [应用物理学];
学科分类号
摘要
This paper reports the effects of sinusoidal microwave power Amplitude Modulation (AM) on the performance of Electron Cyclotron Resonance (ECR) ion sources. The study was conducted on the 14 GHz ECR ion source ECR2 at the University of Jyvaskyla. The klystron output was intentionally altered by a variable frequency sinusoidal amplitude modulation. The average microwave power 350 W was modulated between 530 W and 180 W from 0.011-25 kHz. The integrated x-ray energy, the mass analyzed beam current and the forward and reflected microwave power were measured. The energy integrated x-ray signal responded strongly with low frequency modulation and was no longer observable at approximately 2.2 kHz where the signal strength became solely dependent on the time averaged power. The beam current responded in a similar way but exhibited a strong dependence with magnetic field. Qualitatively, we found source tuning parameters where AM effects were reduced also produced the highest currents of Ne8+ in Continuous Wave (CW) mode. Furthermore, these parameters are typically used for optimized beam injection into the K130 cyclotron. The dependence of beam current and the x-ray signal modulation on AM frequency for different magnetic fields are reported. A qualitative interpretation of the results will be given.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Resonance surface, microwave power absorption, and plasma density distribution in an electron cyclotron resonance ion source
    Salahshoor, M.
    Aslaninejad, M.
    [J]. PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2019, 22 (04):
  • [2] Summary of the performances of the superconducting electron cyclotron resonance ion source at 14 GHz
    Ludwig, P
    Bourg, F
    Briand, P
    Girard, A
    Melin, G
    Guillaume, D
    Seyfert, P
    La Grassa, A
    Ciavola, G
    Gammino, S
    Castro, M
    Chines, F
    Marletta, S
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (12): : 4082 - 4085
  • [3] Summary of the performances of the superconducting electron cyclotron resonance ion source at 14 GHz
    CEA, Grenoble, France
    [J]. Rev Sci Instrum, 12 (4082-4085):
  • [4] The effect of plasma electrode collar structure on the performance of the JYFL 14 GHz electron cyclotron resonance ion source
    Toivanen, V.
    Tarvainen, O.
    Komppula, J.
    Koivisto, H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 726 : 41 - 46
  • [5] Beam development at the new 14 GHz electron cyclotron resonance ion source of ATOMKI
    Biri, S
    Vamosi, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 646 - 648
  • [6] Time resolved experiments at the Frankfurt 14 GHz electron cyclotron resonance ion source
    Runkel, S
    Hohn, O
    Stiebing, KE
    Schempp, A
    Schmidt-Böcking, H
    Mironov, V
    Shirkov, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 912 - 914
  • [7] Plasma potential profile in a 2.45 GHz electron cyclotron resonance multicharged ion source
    Kato, Y
    Ishii, S
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 1176 - 1178
  • [8] Electron-beam extraction system for the Frankfurt 14 GHz electron cyclotron resonance ion source
    Runkel, S
    Hohn, O
    Schmidt, L
    Stiebing, KE
    Schmidt-Bocking, H
    Schempp, A
    Becker, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 721 - 723
  • [9] Electron-beam extraction system for the Frankfurt 14 GHz electron cyclotron resonance ion source
    Runkel, S.
    Hohn, O.
    Schmidt, L.
    Stiebing, K.E.
    Schmidt-Bocking, H.
    Schempp, A.
    Becker, R.
    [J]. Review of Scientific Instruments, 1998, 69 (2 pt 2):
  • [10] Effect of the gas mixing technique on the plasma potential and emittance of the JYFL 14 GHz electron cyclotron resonance ion source
    Tarvainen, O
    Suominen, P
    Ropponen, T
    Kalvas, T
    Heikkinen, P
    Koivisto, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (09):