VG-DropDNet a Robust Architecture for Blood Vessels Segmentation on Retinal Image

被引:4
|
作者
Desiani, Anita [1 ]
Erwin [2 ]
Suprihatin, Bambang [1 ]
Efriliyanti, Filda [3 ]
Arhami, Muhammad [4 ]
Setyaningsih, Emy [5 ]
机构
[1] Univ Sriwijaya, Math & Nat Sci Fac, Math Dept, Indralaya 30662, Indonesia
[2] Univ Sriwijaya, Comp Sci Fac, Comp Engn Dept, Indralaya 30662, Indonesia
[3] Univ Sriwijaya, Math & Nat Sci Fac, Computat Lab, Indralaya 30662, Indonesia
[4] Politekn Negeri Lhokseumawe, Informat Engn Dept, Lhokseumawe 24375, Indonesia
[5] Inst Sains & Teknol Akprind, Comp Syst Dept, Yogyakarta 55222, Indonesia
来源
IEEE ACCESS | 2022年 / 10卷
关键词
Computer architecture; Image segmentation; Retina; Blood vessels; Sensitivity; Neurons; Medical diagnostic imaging; DenseNet; retinal image; segmentation; U-Net; VG-DropDNet; CONDITIONAL RANDOM-FIELD; NEURAL-NETWORK; AUTOMATIC SEGMENTATION; MODELS;
D O I
10.1109/ACCESS.2022.3202890
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Additional layers to the U-Net architecture leads to additional parameters and network complexity. The Visual Geometry Group (VGG) architecture with 16 backbones can overcome the problem with small convolutions. Dense Connected (DenseNet) can be used to avoid excessive feature learning in VGG by directly connecting each layer using input from the previous feature map. Adding a Dropout layer can protect DenseNet from Overfitting problems. This study proposes a VG-DropDNet architecture that combines VGG, DenseNet, and U-Net with a dropout layer in blood vessels retinal segmentation. VG-DropDNet is applied to Digital Retina Image for Vessel Extraction (DRIVE) and Retina Structured Analysis (STARE) datasets. The results on DRIVE give great accuracy of 95.36%, sensitivity of 79.74% and specificity of 97.61%. The F1-score on DRIVE of 0.8144 indicates that VG-DropDNet has great precision and recall. The IoU result is 68.70. It concludes that the resulting image of VG-DropDNet has a great resemblance to its ground truth. The results on STARE are excellent for accuracy of 98.56%, sensitivity of 91.24%, specificity of 92.99% and IoU of 86.90%. The results of the VGG-DropDNet on STARE show that the proposed method is excellent and robust for blood vessels retinal segmentation. The Cohen's Kappa coefficient obtained by VG-DropDNet at DRIVe is 0.8386 and at STARE is 0.98, it explains that the VG-DropDNet results are consistent and precise in both datasets. The results on various datasets indicate that VG-DropDnet is effective, robust and stable in retinal image blood vessel segmentation.
引用
收藏
页码:92067 / 92083
页数:17
相关论文
共 50 条
  • [1] A ROBUST TECHNIQUES OF ENHANCEMENT AND SEGMENTATION BLOOD VESSELS IN RETINAL IMAGE USING DEEP LEARNING
    Desiani, Anita
    Erwin
    Suprihatin, Bambang
    Agustina, Sinta Bella
    [J]. Biomedical Engineering - Applications, Basis and Communications, 2022, 34 (04)
  • [2] A ROBUST TECHNIQUES OF ENHANCEMENT AND SEGMENTATION BLOOD VESSELS IN RETINAL IMAGE USING DEEP LEARNING
    Desiani, Anita
    Erwin
    Suprihatin, Bambang
    Agustina, Sinta Bella
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2022, 34 (04):
  • [3] Improved Blood Vessels Segmentation of Retinal Image of Infants
    Kumar, Vijay
    Patel, Het
    Paul, Kolin
    Surve, Abhidnya
    Azad, Shorya
    Chawla, Rohan
    [J]. HEALTHINF: PROCEEDINGS OF THE 15TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES - VOL 5: HEALTHINF, 2021, : 142 - 153
  • [4] A method for segmentation of retinal image vessels
    Huang, Shuying
    Zhang, Erhu
    [J]. WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 435 - 435
  • [5] Auto-segmentation of Retinal Blood Vessels Using Image Processing
    Bantan, Malak T.
    [J]. 2016 4TH SAUDI INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY (BIG DATA ANALYSIS) (KACSTIT), 2016, : 38 - 43
  • [6] A Deep Convolutional Encoder-Decoder Architecture for Retinal Blood Vessels Segmentation
    Adeyinka, Adegun Adekanmi
    Adebiyi, Marion Olubunmi
    Akande, Noah Oluwatobi
    Ogundokun, Roseline Oluwaseun
    Kayode, Anthonia Aderonke
    Oladele, Tinuke Omolewa
    [J]. COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2019, PT V: 19TH INTERNATIONAL CONFERENCE, SAINT PETERSBURG, RUSSIA, JULY 14, 2019, PROCEEDINGS, PART V, 2019, 11623 : 180 - 189
  • [7] Research on the Segmentation of Retinal Blood Vessels
    Yang, Yong
    Zhou, Yuan
    Rao, Nini
    [J]. 2011 INTERNATIONAL CONFERENCE ON FUTURE COMPUTER SCIENCE AND APPLICATION (FCSA 2011), VOL 1, 2011, : 261 - 264
  • [8] A ROBUST ALGORITHM FOR SEGMENTATION OF BLOOD VESSELS IN THE PRESENCE OF LESIONS IN RETINAL FUNDUS IMAGES
    Awan, Amna Waheed
    Awan, Zahra Waheed
    Akram, Muhammad Usman
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST) PROCEEDINGS, 2015, : 110 - 115
  • [9] Robust segmentation of vessels from retinal angiography
    Zana, F
    Klein, JC
    [J]. DSP 97: 1997 13TH INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING PROCEEDINGS, VOLS 1 AND 2: SPECIAL SESSIONS, 1997, : 1087 - 1090
  • [10] Impact of Image Enhancement Technique on CNN Model for Retinal Blood Vessels Segmentation
    Soomro, Toufique Ahmed
    Afifi, Ahmed J.
    Shah, Ahmed Ali
    Soomro, Shafiullah
    Baloch, Gulsher Ali
    Zheng, Lihong
    Yin, Ming
    Gao, Junbin
    [J]. IEEE ACCESS, 2019, 7 : 158183 - 158197