In vivo knee moments and shear after total knee arthroplasty

被引:131
|
作者
D'Lima, Darryl D.
Patil, Shantanu
Steklov, Nikolai
Chien, Shu
Colwell, Clifford W., Jr.
机构
[1] Shiley Ctr Orthopaed Res & Educ Scripps Clin, La Jolla, CA 92037 USA
[2] Univ Calif San Diego, Dept Bioengn, San Diego, CA USA
关键词
total knee arthroplasty; knee forces; in vivo; knee sheer; knee rnoments; CHAIR HEIGHT; DEEP FLEXION; OLDER-ADULTS; FORCES; WALKING; JOINT; OSTEOARTHRITIS; GAIT; MECHANICS; OBESITY;
D O I
10.1016/j.jbiomech.2007.03.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Tibiofemoral loading is very important in cartilage degeneration as well as in component survivorship after total knee arthroplasty. We have previously reported the axial knee forces in vivo. In this study, a second-generation force-sensing device that measured all six components of tibial forces was implanted in a 74-kg, 83-year-old male. Video motion analysis, ground reaction forces, and knee forces were measured during walking, stair climbing, chair-rise, and squat activities. Peak total force was 2.3 times body weight (BW) during walking, 2.5 x BW during chair rise, 3.0 x BW during stair climbing, and 2.1 x BW during squatting. Peak anterior shear force at the tibial tray was 0.30 x BW during walking, 0.17 x BW during chair rise, 0.26 x BW during stair climbing, and 0.15 x BW during squatting. Peak flexion moment at the tray was 1.9% BW x Ht (percentage of body weight Multiplied by height) for chair-rise activity and 1.7% BW x Ht for squat activity. Peak adduction moment at the tray was -1.1% BW x Ht during chair-rise, -1.3% BW x Ht during squatting. External knee flexion and adduction moments were substantially greater than flexion and adduction moments at the tray. The axial component of forces predominated especially during the stance phase of walking. Shear forces and moments at the tray were very modest compared to total knee forces. These findings indicate that the soft tissues around the knee absorbed most of the external shear forces. Our results highlight the importance of direct measurements of knee forces. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S11 / S17
页数:7
相关论文
共 50 条
  • [1] Sagittal laxity in vivo after total knee arthroplasty
    Yoshinori Ishii
    Yoshikazu Matsuda
    Ryo Ishii
    Shigeo Sakata
    Go Omori
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 249 - 253
  • [2] The Chitranjan Ranawat Award - In vivo knee forces after total knee arthroplasty
    D'Lima, DD
    Patil, S
    Steklov, N
    Slamin, JE
    Colwell, CW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) : 45 - 49
  • [3] Sagittal laxity in vivo after total knee arthroplasty
    Ishii, Y
    Matsuda, Y
    Ishii, R
    Sakata, S
    Omori, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (04) : 249 - 253
  • [4] The painful knee after total knee arthroplasty
    R. Becker
    M. Bonnin
    S. Hofmann
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19
  • [5] KNEE INSTABILITY AFTER TOTAL KNEE ARTHROPLASTY
    FEHRING, TK
    VALADIE, AL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (299) : 157 - 162
  • [6] Knee strength after total knee arthroplasty
    Silva, M
    Shepherd, EF
    Jackson, WO
    Pratt, JA
    McClung, CD
    Schmalzried, TP
    JOURNAL OF ARTHROPLASTY, 2003, 18 (05): : 605 - 611
  • [7] The painful knee after total knee arthroplasty
    Becker, R.
    Bonnin, M.
    Hofmann, S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) : 1409 - 1410
  • [8] Multicenter determination of in vivo kinematics after total knee arthroplasty
    Dennis, DA
    Komistek, RD
    Mahfouz, MR
    Haas, BD
    Stiehl, JB
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) : 37 - 57
  • [9] Tibial forces measured in vivo after total knee arthroplasty
    D'Lima, DD
    Patil, S
    Steklov, N
    Slamin, JE
    Colwell, CW
    JOURNAL OF ARTHROPLASTY, 2006, 21 (02): : 255 - 262
  • [10] Changes in knee alignment after total knee arthroplasty
    Matsuda, S
    Miura, H
    Nagamine, R
    Urabe, K
    Harimaya, K
    Matsunobu, T
    Iwamoto, Y
    JOURNAL OF ARTHROPLASTY, 1999, 14 (05): : 566 - 570