Heart and Lung Sound Measurement Using an Esophageal Stethoscope with Adaptive Noise Cancellation

被引:6
|
作者
Mohamed, Nourelhuda [1 ]
Kim, Hyun-Seok [2 ]
Kang, Kyu-Min [3 ]
Mohamed, Manal [1 ]
Kim, Sung-Hoon [3 ]
Kim, Jae Gwan [1 ]
机构
[1] Gwangju Inst Sci & Technol, Biomed Sci & Engn Dept, Gwangju 61005, South Korea
[2] Asan Med Ctr, Biomed Engn Res Ctr, Asan Inst Life Sci, Seoul 05505, South Korea
[3] Univ Ulsan, Asan Med Ctr, Dept Anesthesiol & Pain Med, Coll Med, Seoul 05505, South Korea
关键词
digital esophageal stethoscope; esophageal catheter; adaptive noise canceling; least mean square; SIMULINK;
D O I
10.3390/s21206757
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In surgeries where general anesthesia is required, the auscultation of heart and lung sounds is essential to provide information on the patient's cardiorespiratory system. Heart and lung sounds can be recorded using an esophageal stethoscope; however, there is huge background noise when this device is used in an operating room. In this study, a digital esophageal stethoscope system was designed. A 3D-printed case filled with Polydimethylsiloxane material was designed to hold two electret-type microphones. One of the microphones was placed inside the printed case to collect the heart and lung sound signals coming out from the patient through the esophageal catheter, the other was mounted on the surface of the case to collect the operating room sounds. A developed adaptive noise canceling algorithm was implemented to remove the operating room noise corrupted with the main heart and lung sound signals and the output signal was displayed on software application developed especially for this study. Using the designed case, the noise level of the signal was reduced to some extent, and by adding the adaptive filter, further noise reduction was achieved. The designed system is lightweight and can provide noise-free heart and lung sound signals.</p>
引用
收藏
页数:15
相关论文
共 50 条
  • [1] The embedded digital stethoscope uses the adaptive noise cancellation filter and the Type I Chebyshev IIR bandpass filter to reduce the noise of the heart sound
    Bai, YW
    Lu, CL
    HEALTHCOM 2005: 7TH INTERNATIONAL WORKSHOP ON ENTERPRISE NETWORKING AND COMPUTING IN HEALTHCARE INDUSTRY, PROCEEDINGS, 2005, : 278 - 281
  • [2] Recursive least squares adaptive noise cancellation filtering for heart sound reduction in lung sounds recordings
    Gnitecki, J
    Moussavi, Z
    Pasterkamp, H
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2416 - 2419
  • [3] Wireless Stethoscope for Recording Heart and Lung Sound
    Shi, W. Y.
    Mays, Jeffrey
    Chiao, J. -C.
    2016 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2016, : 1 - 4
  • [4] Heart sound cancellation from lung sound record using cyclostationarity
    Li, Ting
    Tang, Hong
    Qiu, Tianshuang
    Park, Yongwan
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (12) : 1831 - 1836
  • [5] Heart Sound Measurement and Analysis System with Digital Stethoscope
    Wang, Haibin
    Chen, Jian
    Hu, Yuliang
    Jiang, Zhongwei
    Samjin, Choi
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 636 - +
  • [6] Performance Evaluation of Heart Sound Cancellation in FPGA Hardware Implementation for Electronic Stethoscope
    Chao, Chun-Tang
    Maneetien, Nopadon
    Wang, Chi-Jo
    Chiou, Juing-Shian
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [7] Esophageal stethoscope placement depth: Its effect on heart and lung sound monitoring during general anesthesia
    Manecke, GR
    Poppers, PJ
    ANESTHESIA AND ANALGESIA, 1998, 86 (06): : 1276 - 1279
  • [8] Real-time adaptive reduction of heart sounds from lung sound recordings using a new electronic stethoscope
    Yip, L
    Zhang, YT
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 800 - 801
  • [9] Modified adaptive line enhancement filter and its application to heart sound noise cancellation
    Tinati, MA
    Bouzerdoum, A
    Mazumdar, J
    ISSPA 96 - FOURTH INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND ITS APPLICATIONS, PROCEEDINGS, VOLS 1 AND 2, 1996, : 815 - 818
  • [10] Performance of Adaptive Noise Cancellation with Normalized Last-Mean-Square Based on the Signal-to-Noise Ratio of Lung and Heart Sound Separation
    Al-Naggar, Noman Q.
    Al-Udyni, Mohammed H.
    JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018