Analysis of Different Approaches for Clinical Cochlear Coverage Evaluation After Cochlear Implantation

被引:30
|
作者
Schurzig, Daniel [1 ]
Timm, Max Eike [2 ]
Batsoulis, Cornelia [1 ]
John, Samuel [3 ]
Lenarz, Thomas [2 ]
机构
[1] Hannover Res Ctr, MED El Med Elect, Feodor Lynen Str 35, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Otolaryngol, Cluster Excellence Hearing4all, Hannover, Germany
[3] HorSys GmbH, Hannover, Germany
关键词
Cochlear coverage; Cochlear duct length; Cochlear implantation; INSERTION DEPTH; HEARING PRESERVATION; ELECTRODE INSERTION; SPEECH; LENGTH; PERFORMANCE; MORPHOLOGY; SYSTEM; IMPACT; CORTI;
D O I
10.1097/MAO.0000000000001904
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis:Methods for cochlear coverage determination vary in their accuracy and are hence not equally reliable.Background:The audiological outcome after cochlear implantation is known to depend on several factors. One factor shown to positively correlate with speech perception is the insertion angle. This parameter is one of the ways to describe the fraction of the cochlea spiral exposed to electric stimulation after implantation, also known as cochlear coverage, which itself is dependent on the length and type of electrode array as well as the size and shape of the implanted cochlea. While the assessment of cochlear coverage as the insertion angle is quick and uncomplicated, the accuracy of representing the relative fraction of the cochlea exposed to electric stimulation by this single measurement value remains unknown.Methods:Both the cochlea spiral and implanted electrode array of N=10 cochlear implant patients were traced within clinical imaging data and processed to derive the respective cochlear coverage values. These values were compared to ones derived with alternative measures like the insertion angle as well as other methods to yield the accuracy and reliability of these approaches.Results:The insertion angle as well as two novel approaches were found to be superior to all other analyzed assessment options and well suited for clinical cochlear coverage evaluations.Conclusion:Insertion angle measurements are well suited for cochlear coverage determination, especially regarding retrospective analyses. Prospective studies independent of anatomical irregularities should be performed with the newly proposed approaches.
引用
收藏
页码:E642 / E650
页数:9
相关论文
共 50 条
  • [1] Cochlear Implantation in Pediatrics: The Effect of Cochlear Coverage
    Alothman, Noura
    Almuhawas, Fida
    Badghaish, Reem
    Alotaibi, Al Hanouf
    Alhabib, Salman F.
    Alzhrani, Farid
    Hagr, Abdulrahman
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (03):
  • [2] Cochlear wall erosion after cochlear implantation
    Cervera-Paz, FJ
    Linthicum, FH
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2005, 114 (07): : 543 - 546
  • [3] Auditory Brainstem Implantation After Unsuccessful Cochlear Implantation of Children With Clinical Diagnosis of Cochlear Nerve Deficiency
    Colletti, Liliana
    Wilkinson, Eric P.
    Colletti, Vittorio
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2013, 122 (10): : 605 - 612
  • [4] Cochlear Implantation: Evaluation of Cochlear Duct Length (CDL)
    Mueller-Graff, Fraryz-Tassilo
    Rak, Kristen
    LARYNGO-RHINO-OTOLOGIE, 2022, 101 (05) : 428 - 441
  • [5] Anatomy-Based Frequency Allocation in Cochlear Implantation: The Importance of Cochlear Coverage
    Aljazeeri, Isra
    Hamed, Nezar
    Abdelsamad, Yassin
    Sharif, Tahir
    Al-Momani, Murad
    Hagr, Abdulrahman
    LARYNGOSCOPE, 2022, 132 (11): : 2224 - 2231
  • [6] Hearing Preservation After Complete Cochlear Coverage in Cochlear Implantation With the Free-Fitting FLEXSOFT Electrode Carrier
    Helbig, Silke
    Baumann, Uwe
    Hey, Constanze
    Helbig, Matthias
    OTOLOGY & NEUROTOLOGY, 2011, 32 (06) : 973 - 979
  • [7] Evaluation of the results of cochlear implantation
    Hssaine, Khaoula
    Belhoucha, Btissam
    Benhommad, Othman
    Rochdi, Youssef
    Nouri, Hassan
    Aderdour, Lahcen
    Raji, Abdelaziz
    PAN AFRICAN MEDICAL JOURNAL, 2015, 22
  • [8] Economic evaluation of cochlear implantation
    Wong, BYK
    Hui, Y
    Au, D
    Wei, W
    UPDATES IN COCHLEAR IMPLANTATION, 2000, 57 : 377 - 381
  • [9] Meningitis after cochlear implantation
    Wei, Benjamin P. C.
    Clark, Graeme M.
    O'Leary, Stephen J.
    Shepherd, Robert K.
    Robins-Browne, Roy M.
    BRITISH MEDICAL JOURNAL, 2007, 335 (7629): : 1058 - 1058
  • [10] Tinnitus after cochlear implantation
    Akdogan, Ozgur
    Ozcan, Ibrahim
    Ozbek, Cem
    Dere, Huseyin
    AURIS NASUS LARYNX, 2009, 36 (02) : 210 - 212