Impact of weathering on flashover performance of nonceramic insulators

被引:13
|
作者
Venkataraman, S. [1 ]
Gorur, R. S. [1 ]
Mishra, A. P. [1 ]
机构
[1] Arizona State Univ, Dept Elect Engn, Tempe, AZ 85287 USA
关键词
nonceramic; composite; polymeric insulators; SEM; surface resistance; flashover; ESDD; surface degradation;
D O I
10.1109/TDEI.2008.4591230
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nonceramic (composite) insulators that were in service on 69-230 kV transmission lines for periods up to 25 years were evaluated in the laboratory with the objective of assessing future performance of similar devices in the field. These insulators had housings made from different formulations of silicone rubber and ethylene propylene diene monomer (EPDM) rubber. They were removed from relatively clean locations where weathering was probably the most dominant aging factor. Some EPDM insulators had flashed over during service. Using a combination of scanning electron microscopy (SEM), electrical surface resistance under wet conditions, and a theoretical model for contamination flashover, it has been shown that it is possible to predict the flashover performance in service, based on the thickness of the degraded surface. A threshold value has been established beyond which flashover is likely to occur in the field. This information can be used for planning insulator replacement or maintenance.
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 50 条
  • [1] Estimation of flashover probability of aged nonceramic insulators in service
    Montesinos, J
    Gorur, RS
    Burnham, J
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (02) : 820 - 826
  • [2] Flashover of contaminated nonceramic outdoor insulators in a wet atmosphere
    de la O, A
    Gorur, RS
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1998, 5 (06) : 814 - 823
  • [3] Sudden flashover of nonceramic insulators in artificial contamination tests
    Gorur, RS
    DeLaO, A
    ElKishky, H
    Chowdhary, M
    Mukherjee, H
    Sundaram, R
    Burnham, JT
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1997, 4 (01) : 79 - 87
  • [4] Non linear regression model to predict flashover of nonceramic insulators
    Venkataraman, S.
    Gorur, R. S.
    [J]. 2006 38TH ANNUAL NORTH AMERICAN POWER SYMPOSIUM, NAPS-2006 PROCEEDINGS, 2006, : 663 - +
  • [5] Mold growth on nonceramic insulators and its impact on electrical performance
    Gorur, RS
    Montesinos, J
    Roberson, R
    Burnham, J
    Hill, R
    [J]. 1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 818 - 822
  • [6] Mold growth on nonceramic insulators and its impact on electrical performance
    Gorur, RS
    Montesinos, J
    Roberson, R
    Burnham, J
    Hill, R
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (02) : 559 - 563
  • [7] Impact of corona on the long-term performance of nonceramic insulators
    Moreno, VM
    Gorur, RS
    Kroese, A
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2003, 10 (01) : 80 - 95
  • [8] Impact of corona on the long-term performance of nonceramic insulators
    Las, T
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2004, 11 (05) : 913 - 914
  • [9] ACCELERATED AGING AND FLASHOVER TESTS ON 138 KV NONCERAMIC LINE POST INSULATORS
    SCHNEIDER, HM
    GUIDI, WW
    BURNHAM, JT
    GORUR, RS
    HALL, JF
    LAMPE, WD
    FINI, GP
    MARRONE, G
    PORRINO, A
    MCELROY, AJ
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (01) : 325 - 336
  • [10] Sudden flashover of nonceramic insulators in artificial contamination tests (vol 4, pg 9, 1997)
    Gorur, RS
    DelaO, A
    ElKishky, H
    Chowdhary, M
    Mukherjee, H
    Sundaram, R
    Burnham, JT
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1997, 4 (03) : 348 - 348