High-performance electrochemical sensor based on molecularly imprinted polypyrrole-graphene modified glassy carbon electrode

被引:22
|
作者
Oliveira, S. M. [1 ,2 ]
Luzardo, J. M. [1 ]
Silva, L. A. [1 ]
Aguiar, D. C. [1 ]
Senna, C. A. [1 ]
Verdan, R. [1 ]
Kuznetsov, A. [1 ]
Vasconcelos, T. L. [1 ]
Archanjo, B. S. [1 ]
Achete, C. A. [1 ]
D'Elia, Eliane [2 ]
Araujo, J. R. [1 ]
机构
[1] Natl Inst Metrol Qual & Technol Inmetro, Mat Metrol Div, Av Nossa Senhora Gracas 50, BR-25250020 Duque De Caxias, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Inst Quim, Av Athos Silveira Ramos,149,Cidade Univ, BR-21044020 Rio De Janeiro, Brazil
关键词
Graphene; Molecularly imprinted polymer; Polypyrrole; Ascorbic acid; Electrochemical sensor; VOLTAMMETRIC DETERMINATION; ASCORBIC-ACID; CONDUCTING POLYMER; PASTE ELECTRODE; GRAPHITE; NOREPINEPHRINE; NANOPARTICLES; EPINEPHRINE; NANOTUBES; OXIDE;
D O I
10.1016/j.tsf.2020.137875
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Molecularly imprinted polymers are pushing the limits of sensing capabilities in electrochemical sensors. As a result, these sensors are driving the improvement of chemical species detection with applications in pharmaceutical, chemical and food industries as well as showing potential for bioanalytes sensing for applications in medical diagnostics. In particular, molecularly imprinted polymer-graphene sensors have great potential to increase the selectivity, sensitivity and detectability of electrochemical sensors for organic molecules determination, especially in the presence of interferers. In this work, we tested three different coatings on glassy carbon electrode for the purpose of ascorbic acid quantification: graphene, molecular imprinted polypyrrole-graphene and non-imprinted polypyrrole-graphene. Among the prepared electrodes, non-imprinted and molecularly imprinted polypyrrole on graphene, exhibited the highest sensitivity to ascorbic acid (6.14 and 5.87 mu A/mmol L-1, respectively), although their detection limit (0.56 and 0.10 mmol L-1, respectively) was poore than the uncoated graphene one (0.02 mmol L-1). Besides that, graphene modified glassy carbon electrode showed better response for repetitive uses. However, in the case of a unique measurement to detect the presence of ascorbic acid in a solution containing interferers, as uric acid and dopamine, molecular imprinted polypyrrole-graphene electrode exhibits better response and selectivity in addition to, an electrocatalytic effect.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A halofuginone electrochemical sensor based on a molecularly imprinted polypyrrole coated glassy carbon electrode
    Radi, Abd-Elgawad
    Abd-Elaziz, Ismael
    [J]. ANALYTICAL METHODS, 2015, 7 (19) : 8152 - 8158
  • [2] A sensitive sensor based on molecularly imprinted polypyrrole on reduced graphene oxide modified glassy carbon electrode for nevirapine analysis
    Hassan Pour, Bayazid
    Haghnazari, Nahid
    Keshavarzi, Fatemeh
    Ahmadi, Elahe
    Zarif, Bahareh Rahimian
    [J]. ANALYTICAL METHODS, 2021, 13 (40) : 4767 - 4777
  • [3] Electrochemical sensor for levofloxacin based on molecularly imprinted polypyrrole-graphene-gold nanoparticles modified electrode
    Wang, Fei
    Zhu, Lihua
    Zhang, Jingdong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 192 : 642 - 647
  • [4] Trace anthracene electrochemical detection based on electropolymerized-molecularly imprinted polypyrrole modified glassy carbon electrode
    Mathieu-Scheers, Emilie
    Bouden, Sarra
    Grillot, Celine
    Nicolle, Jimmy
    Warmont, Fabienne
    Bertagna, Valerie
    Cagnon, Benoit
    Vautrin-Ul, Christine
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 848
  • [5] Electrochemical detection of hydroquinone in wastewater using polypyrrole-graphene nanocomposite-modified glassy carbon electrode
    Bhagat, S.
    Aziz, A.
    Buledi, J. A.
    Shaikh, H.
    Solangi, A. R.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2024,
  • [6] A novel electrochemical sensor for isocarbophos based on a glassy carbon electrode modified with electropolymerized molecularly imprinted terpolymer
    Yan, Xiaona
    Deng, Jian
    Xu, Jinsheng
    Li, Hui
    Wang, Lili
    Chen, Dan
    Xie, Jie
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1087 - 1094
  • [7] Molecularly imprinted electrochemical sensor based on a reduced graphene modified carbon electrode for tetrabromobisphenol A detection
    Chen, Hong-Jun
    Zhang, Zhao-Hui
    Cai, Rong
    Kong, Xiang-Quan
    Chen, Xing
    Liu, Yu-Nan
    Yao, Shou-Zhuo
    [J]. ANALYST, 2013, 138 (09) : 2769 - 2776
  • [8] Polypyrrole Molecularly Imprinted Modified Glassy Carbon Electrode for the Recognition of Gallic Acid
    Jara-Ulloa, Paola
    Salgado-Figueroa, Paola
    Moscoso, Raul
    Arturo Squella, Juan
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : H243 - H246
  • [9] Voltammetric Determination of Flunixin on Molecularly Imprinted Polypyrrole Modified Glassy Carbon Electrode
    Radi, Abd-Elgawad
    Abd El-Ghany, Nadia
    Wahdan, Tarek
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2016, 2016
  • [10] Electrochemical Sensor for Detection of Trichlorfon Based on Molecularly Imprinted Sol–Gel Films Modified Glassy Carbon Electrode
    Weiqiang Gao
    Fuwei Wan
    Wei Ni
    Shaowei Wang
    Meng Zhang
    Jinghua Yu
    [J]. Journal of Inorganic and Organometallic Polymers and Materials, 2012, 22 : 37 - 41