Dosimetric measurements of an n-butyl cyanoacrylate embolization material for arteriovenous malformations
被引:7
|
作者:
Labby, Zacariah E.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Wisconsin, Dept Human Oncol, Madison, WI 53792 USAUniv Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
Labby, Zacariah E.
[1
]
Chaudhary, Neeraj
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan Hosp & Hlth Syst, Dept Radiol, Div Neurointervent Radiol, Ann Arbor, MI 48109 USA
Univ Michigan Hosp & Hlth Syst, Dept Neurosurg, Ann Arbor, MI 48109 USAUniv Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
Chaudhary, Neeraj
[2
,3
]
Gemmete, Joseph J.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan Hosp & Hlth Syst, Dept Radiol, Div Neurointervent Radiol, Ann Arbor, MI 48109 USA
Univ Michigan Hosp & Hlth Syst, Dept Neurosurg, Ann Arbor, MI 48109 USA
Univ Michigan Hosp & Hlth Syst, Dept Otolaryngol, Ann Arbor, MI 48109 USAUniv Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
Gemmete, Joseph J.
[2
,3
,4
]
Pandey, Aditya S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan Hosp & Hlth Syst, Dept Neurosurg, Ann Arbor, MI 48109 USAUniv Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
Pandey, Aditya S.
[3
]
Roberts, Donald A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan Hosp & Hlth Syst, Dept Radiat Oncol, Radiat Phys Div, Ann Arbor, MI 48109 USAUniv Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
Roberts, Donald A.
[5
]
机构:
[1] Univ Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
[2] Univ Michigan Hosp & Hlth Syst, Dept Radiol, Div Neurointervent Radiol, Ann Arbor, MI 48109 USA
[3] Univ Michigan Hosp & Hlth Syst, Dept Neurosurg, Ann Arbor, MI 48109 USA
[4] Univ Michigan Hosp & Hlth Syst, Dept Otolaryngol, Ann Arbor, MI 48109 USA
[5] Univ Michigan Hosp & Hlth Syst, Dept Radiat Oncol, Radiat Phys Div, Ann Arbor, MI 48109 USA
Purpose: The therapeutic regimen for cranial arteriovenous malformations often involves both stereotactic radiosurgery and endovascular embolization. Embolization agents may contain tantalum or other contrast agents to assist the neurointerventionalists, leading to concerns regarding the dosimetric effects of these agents. This study investigated dosimetric properties of n-butyl cyanoacrylate (n-BCA) plus lipiodol with and without tantalum powder. Methods: The embolization agents were provided cured from the manufacturer with and without added tantalum. Attenuation measurements were made for the samples and compared to the attenuation of a solid water substitute using a 6 MV photon beam. Effective linear attenuation coefficients (ELAC) were derived from attenuation measurements made using a portal imager and derived sample thickness maps projected in an identical geometry. Probable dosimetric errors for calculations in which the embolized regions are overridden with the properties of water were calculated using the ELAC values. Interface effects were investigated using a parallel plate ion chamber placed at set distances below fixed samples. Finally, Hounsfield units (HU) were measured using a stereotactic radiosurgery CT protocol, and more appropriate HU values were derived from the ELAC results and the CT scanner's HU calibration curve. Results: The ELAC was 0.0516 +/- 0.0063 cm(-1) and 0.0580 +/- 0.0091 cm(-1) for n-BCA without and with tantalum, respectively, compared to 0.0487 +/- 0.0009 cm(-1) for the water substitute. Dose calculations with the embolized region set to be water equivalent in the treatment planning system would result in errors of -0.29% and -0.93% per cm thickness of n-BCA without and with tantalum, respectively. Interface effects compared to water were small in magnitude and limited in distance for both embolization materials. CT values at 120 kVp were 2082 and 2358 HU for n-BCA without and with tantalum, respectively; dosimetrically appropriate HU values were estimated to be 79 and 199 HU, respectively. Conclusions: The dosimetric properties of the embolization agents are very close to those of water for a 6 MV beam. Therefore, treating the entire intracranial space as uniform in composition will result in less than 1% dosimetric error for n-BCA emboli smaller than 3.4 cm without added tantalum and n-BCA emboli smaller than 1.1 cm with added tantalum. Furthermore, when effective embolization can be achieved by the neurointerventionalist using n-BCA without tantalum, the dosimetric impact of overriding material properties will be lessened. However, due to the high attenuation of embolization agents with and without added tantalum for diagnostic energies, artifacts may occur that necessitate additional imaging to accurately identify the spatial extent of the region to be treated. (C) 2015 American Association of Physicists in Medicine.
机构:
Boston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Harvard Med Sch, 300 Longwood Ave, Boston, MA 02115 USA
Boston Childrens Hosp, Div Vasc & Intervent Radiol, 300 Longwood Ave, Boston, MA 02115 USABoston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Uller, Wibke
El-sobky, Sherif
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Harvard Med Sch, 300 Longwood Ave, Boston, MA 02115 USA
Boston Childrens Hosp, Div Vasc & Intervent Radiol, 300 Longwood Ave, Boston, MA 02115 USABoston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
El-sobky, Sherif
Alomari, Ahmad I.
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Harvard Med Sch, 300 Longwood Ave, Boston, MA 02115 USA
Boston Childrens Hosp, Div Vasc & Intervent Radiol, 300 Longwood Ave, Boston, MA 02115 USABoston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Alomari, Ahmad I.
Fishman, Steven J.
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Harvard Med Sch, 300 Longwood Ave, Boston, MA 02115 USA
Boston Childrens Hosp, Dept Surg, Boston, MA USABoston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Fishman, Steven J.
Spencer, Samantha A.
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Harvard Med Sch, 300 Longwood Ave, Boston, MA 02115 USA
Boston Childrens Hosp, Dept Orthopaed, Boston, MA USABoston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Spencer, Samantha A.
Taghinia, Amir H.
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Harvard Med Sch, 300 Longwood Ave, Boston, MA 02115 USA
Boston Childrens Hosp, Dept Plast Surg, Boston, MA USABoston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Taghinia, Amir H.
Chaudry, Gulraiz
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA
Harvard Med Sch, 300 Longwood Ave, Boston, MA 02115 USA
Boston Childrens Hosp, Div Vasc & Intervent Radiol, 300 Longwood Ave, Boston, MA 02115 USABoston Childrens Hosp, Vasc Anomalies Ctr, Boston, MA USA