An integrated scheme for a directional relay in the presence of a series-compensated line

被引:15
|
作者
Adly, Ahmed R. [1 ]
Ali, Ziad M. [2 ,3 ]
Elsadd, Mahmoud A. [4 ]
Mageed, Hala M. Abdel [5 ]
Aleem, Shady H. E. Abdel [6 ]
机构
[1] Atom Energy Author, Nucl Res Ctr, Cairo, Egypt
[2] Prince Sattam Bin Abdulaziz Univ, Coll Engn Wadi Addawaser, Elect Engn Dept, Wadi Addawasir 11991, Saudi Arabia
[3] Aswan Univ, Aswan Fac Engn, Elect Engn Dept, Aswan 81542, Egypt
[4] Menoufia Univ, Fac Engn, Shibin Al Kawm, Egypt
[5] Natl Inst Stand, Giza, Egypt
[6] 15th May Higher Inst Engn, Math & Phys Sci Dept, Cairo, Egypt
关键词
Directional protection; Power flow; Power system faults; Series-compensated transmission lines; DOUBLE-CIRCUIT LINE; TRANSMISSION-LINES; PROTECTION; ALGORITHM;
D O I
10.1016/j.ijepes.2020.106024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an integrated method to identify the fault direction in the presence of a series compensator via also identifying the power flow direction. The presented method relies on monitoring both measured angle of the positive-sequence (PS) currents and magnitude of PS voltage. The change of PS voltage magnitude is used to detect the current inversion case. The presented criteria depend on the power flow direction before the fault occurrence. Therefore, a power flow direction identification method is presented using only the change of the phase angle of the PS current. Different system configurations are investigated to test the reliability of the proposed protection scheme (PPS). The power and protection systems' configurations contain different capacitor ratios leading to current and voltage inversion scenarios, reversing the power flow direction and single-pole tripping. Simulation experiments conducted via the software ATP-EMTP has shown the proper operability of the PPS.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Directional Relaying of Series-compensated Line Using an Integrated Approach
    Biswal, M.
    Pati, B. B.
    Pradhan, A. K.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (07) : 691 - 710
  • [2] A Positive-Sequence Directional Relaying Algorithm for Series-Compensated Line
    Jena, Premalata
    Pradhan, Ashok Kumar
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2288 - 2298
  • [3] Faulty Line Identification by Distance Relay in Series-Compensated Parallel Transmission Lines
    Venkatesh, C.
    Swarup, K. Shanti
    [J]. 2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [4] A new differential protection scheme for fixed series-compensated transmission line
    Ruchika Gupta
    Shoyab Ali
    Gaurav Kapoor
    [J]. Multiscale and Multidisciplinary Modeling, Experiments and Design, 2022, 5 : 1 - 30
  • [5] A new differential protection scheme for fixed series-compensated transmission line
    Gupta, Ruchika
    Ali, Shoyab
    Kapoor, Gaurav
    [J]. MULTISCALE AND MULTIDISCIPLINARY MODELING EXPERIMENTS AND DESIGN, 2022, 5 (01) : 1 - 30
  • [6] Advances in Series-Compensated Line Protection
    Altuve, Hector J.
    Mooney, Joseph B.
    Alexander, George E.
    [J]. 2009 62ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2009, : 263 - 275
  • [7] Higher order statistics-fuzzy integrated scheme for fault classification of a series-compensated transmission line
    Pradhan, AK
    Routray, A
    Biswal, B
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) : 891 - 893
  • [8] Wavelet packet transform applied to a series-compensated line: A novel scheme for fault identification
    Adly, Ahmed R.
    Aleem, Shady H. E. Abdel
    Elsadd, Mahmoud A.
    Ali, Ziad M.
    [J]. MEASUREMENT, 2020, 151
  • [9] PROTECTIVE SCHEME FOR SERIES-COMPENSATED TRANSMISSION-LINES
    SANDERSON, JV
    WRIGHT, A
    [J]. PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1974, 121 (11): : 1377 - 1384
  • [10] Superimposed Energy-based Fault Detection and Classification Scheme for Series-compensated Line
    Gupta, Om Hari
    Tripathy, Manoj