Minimum variance beamforming for high frame-rate ultrasound imaging

被引:45
|
作者
Holfort, Then Kraglund [1 ]
Gran, Fredrik [1 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Orsted DTU, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
关键词
D O I
10.1109/ULTSYM.2007.388
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper investigates the application of adaptive beamforming in medical ultrasound imaging. A minimum variance (MV) approach for near-field beamforming of broadband data is proposed. The approach is implemented in the frequency domain, and it provides a set of adapted, complex apodization weights for each frequency sub-band. As opposed to the conventional, Delay and Sum (DS) beamformer, this approach is dependent on the specific data. The performance of the proposed MV beamformer is tested on simulated synthetic aperture (SA) ultrasound data, obtained using Field II. For the simulations, a 7 MHz, 128-element, phased array transducer with lambda/2-spacing was used. Data is obtained using a single element as the transmitting aperture and all 128 elements as the receiving aperture. A full SA sequence consisting of 128 emissions was simulated by gliding the active transmitting element across the array. Data for 13 point targets and a circular cyst with a radius of 5 mm were simulated. The performance of the MV beamformer is compared to DS using boxcar weights and Hanning weights, and is quantified by the Full Width at Half Maximum (FWHM) and the peak-side-lobe level (PSL). Single emission {DS Boxcar, DS Hanning, MV} provide a PSL of {-16,-36,-49} dB and a FWHM of {0.79,1.33,0.08} mm = {3.59 lambda, 6.05 lambda, 0.36 lambda}. Using all 128 emissions, {DS Boxcar, DS Hanning, MV} provide a PSL of 1-32, -49,-65} dB, and a FWHM of {0.63, 0.97, 0.08} mm = {2.86 lambda, 4.41 lambda, 0.36 lambda}. The contrast of the beamformed single emission responses of the circular cyst were calculated to {-18, -37, -40} dB. The simulations have shown that the frequency sub-band MV beamformer provides a significant increase in lateral resolution compared to DS, even when using considerably fewer emissions. An increase in resolution is seen when using only one single emission. Furthermore, it is seen that an increase of the number of emissions does not alter the FWHM. Thus, the MV beamformer introduces the possibility for high frame-rate imaging with increased resolution.
引用
收藏
页码:1541 / 1544
页数:4
相关论文
共 50 条
  • [1] High Frame-Rate Ultrasound Imaging Using Deep Learning Beamforming
    Ghani, Muhammad Usman
    Meral, F. Can
    Vignon, Francois
    Robert, Jean-luc
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 295 - 298
  • [2] High frame-rate and high resolution medical imaging using adaptive beamforming
    Synnevag, Johan-Fredrik
    Austeng, Andreas
    Holm, Sverre
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2164 - 2167
  • [3] Detecting and Characterizing the Fabella with High Frame-Rate Ultrasound Imaging
    Berthaume, Michael A.
    Toulemonde, Matthieu
    Peralta, Laura
    Christensen-Jeffries, Kirsten
    Grisan, Enrico
    Harput, Sevan
    [J]. PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [4] High Frame-Rate Cardiac Ultrasound Imaging with Deep Learning
    Senouf, Ortal
    Vedula, Sanketh
    Zurakhov, Grigoriy
    Bronstein, Alex
    Zibulevsky, Michael
    Michailovich, Oleg
    Adam, Dan
    Blondheim, David
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT I, 2018, 11070 : 126 - 134
  • [5] Benefits of adaptive beamforming methods for contrast enhanced high frame-rate ultrasound
    Stanziola, A.
    Toulemonde, M.
    Corbett, R.
    Papadopoulou, V.
    Eckersley, R. J.
    Duncan, N.
    Tang, M. -X.
    [J]. 2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [6] Broadband Minimum Variance Beamforming for Ultrasound Imaging
    Holfort, Iben Kraglund
    Gran, Fredrik
    Jensen, Jorgen Arendt
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (02) : 314 - 325
  • [7] Twofold minimum variance beamforming for enhanced ultrasound imaging
    Sayed Mahmoud Sakhaei
    Seyede Elham Shamsian
    [J]. Journal of Medical Ultrasonics, 2018, 45 : 17 - 24
  • [8] Twofold minimum variance beamforming for enhanced ultrasound imaging
    Sakhaei, Sayed Mahmoud
    Shamsian, Seyede Elham
    [J]. JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (01) : 17 - 24
  • [9] High Frame-Rate, High Resolution Ultrasound Imaging With Multi-Line Transmission and Filtered-Delay Multiply And Sum Beamforming
    Matrone, Giulia
    Ramalli, Alessandro
    Savoia, Alessandro Stuart
    Tortoli, Piero
    Magenes, Giovanni
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (02) : 478 - 486
  • [10] Deep Learning Based Minimum Variance Beamforming for Ultrasound Imaging
    Zhuang, Renxin
    Chen, Junying
    [J]. SMART ULTRASOUND IMAGING AND PERINATAL, PRETERM AND PAEDIATRIC IMAGE ANALYSIS, SUSI 2019, PIPPI 2019, 2019, 11798 : 83 - 91