Evaluating visual discomfort in stereoscopic projection-based CAVE system with a close viewing distance

被引:0
|
作者
Song, Weitao [1 ,2 ]
Weng, Dongdong [1 ]
Feng, Dan [1 ]
Li, Yuqian [1 ]
Liu, Yue [1 ]
Wang, Yongtian [1 ]
机构
[1] Beijing Inst Technol, Beijing Engn Res Ctr Mixed Real & Adv Display, Sch Optoelect, Beijing 100081, Peoples R China
[2] Univ Connecticut, Elect & Comp Engn Dept, Storrs, CT 06269 USA
关键词
Visual perception; Visual discomfort; Usability study; Accommodation and convergence conflict; IMAGES;
D O I
10.1117/12.2179610
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As one of popular immersive Virtual Reality (VR) systems, stereoscopic cave automatic virtual environment (CAVE) system is typically consisted of 4 to 6 3m-by-3m sides of a room made of rear-projected screens. While many endeavors have been made to reduce the size of the projection-based CAVE system, the issue of asthenopia caused by lengthy exposure to stereoscopic images in such CAVE with a close viewing distance was seldom tangled. In this paper, we propose a light-weighted approach which utilizes a convex eyepiece to reduce visual discomfort induced by stereoscopic vision. An empirical experiment was conducted to examine the feasibility of convex eyepiece in a large depth of field (DOF) at close viewing distance both objectively and subjectively. The result shows the positive effects of convex eyepiece on the relief of eyestrain.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The accuracy of distance perception in the frontal plane of projection-based stereoscopic environments
    Woldegiorgis, Bereket Haile
    Lin, Chiuhsiang Joe
    [J]. JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2017, 25 (12) : 701 - 711
  • [2] Visual fatigue and discomfort after stereoscopic display viewing
    Zhang, Li
    Zhang, Ya-Qin
    Zhang, Jing-Shang
    Xu, Liang
    Jonas, Jost B.
    [J]. ACTA OPHTHALMOLOGICA, 2013, 91 (02) : e149 - e153
  • [3] Visual comfort/discomfort and visual fatigue caused by stereoscopic HDTV viewing
    Nojiri, Y
    Yamanoue, H
    Hanazato, A
    Emoto, M
    Okano, F
    [J]. STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XI, 2004, 5291 : 303 - 313
  • [4] VISUAL DISCOMFORT INDUCED BY ADJUSTMENT OF CONVERGENCE DISTANCE IN STEREOSCOPIC VIDEO
    Chen, Jianyu
    Zhou, Jun
    Sun, Jun
    [J]. 2013 IEEE INTERNATIONAL SYMPOSIUM ON BROADBAND MULTIMEDIA SYSTEMS AND BROADCASTING (BMSB), 2013,
  • [5] Effects of disparity on visual discomfort caused by short-term stereoscopic viewing based on electroencephalograph analysis
    Xiao Wang
    Liuye Yao
    Yuemei Zhao
    Lidong Xing
    Zhiyu Qian
    Weitao Li
    Yamin Yang
    [J]. BioMedical Engineering OnLine, 17
  • [6] Effects of disparity on visual discomfort caused by short-term stereoscopic viewing based on electroencephalograph analysis
    Wang, Xiao
    Yao, Liuye
    Zhao, Yuemei
    Xing, Lidong
    Qian, Zhiyu
    Li, Weitao
    Yang, Yamin
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [7] Kinematic analysis of direct pointing in projection-based stereoscopic environments
    Lin, Chiuhsiang Joe
    Woldegiorgis, Bereket Haile
    [J]. HUMAN MOVEMENT SCIENCE, 2018, 57 : 21 - 31
  • [8] THE PERCEPTUALLY-SUPPORTED AND THE SUBJECTIVELY-PREFERRED VIEWING DISTANCE OF PROJECTION-BASED LIGHT FIELD DISPLAYS
    Kara, Peter A.
    Guindy, Mary
    Balogh, Tibor
    Simon, Aniko
    [J]. 2021 INTERNATIONAL CONFERENCE ON 3D IMMERSION (IC3D), 2021,
  • [9] Eye movements and visual discomfort when viewing stereoscopic 3D content
    Zhou, Jun
    Wang, Ling
    Yin, Haibing
    Bovik, Alan C.
    [J]. DIGITAL SIGNAL PROCESSING, 2019, 91 : 41 - 53
  • [10] Effect of viewing directions in projection-based multiviewer display systems
    Le Deun, Thomas
    Stoenescu, Daniel
    de la Tocnaye, Jean-Louis de Bougrenet
    [J]. OPTICAL ENGINEERING, 2019, 58 (10)