Assessment of the length of each hemodialysis session by on-line dialysate urea monitoring

被引:6
|
作者
Hernandez-Herrera, G [1 ]
Martin-Malo, A [1 ]
Rodriguez, M [1 ]
Aljama, P [1 ]
机构
[1] Reina Sofia Univ Hosp, Serv Nefrol, Dept Nephrol, E-14004 Cordoba, Spain
来源
NEPHRON | 2001年 / 89卷 / 01期
关键词
dialysis adequacy; hemodialysis length; on-line dialysate urea monitoring;
D O I
10.1159/000046041
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Hemodialysis (HD) prescription is usually based on the periodical measurement of the Kt/V achieved in a midweek dialysis session. The purpose of the study was to assess the duration of each HD session to achieve a target dose of dialysis. This allowed to determine whether a given dialysis session may be considered representative of the other HD sessions. Seventy-two HD sessions were studied in 4 stable patients, who were randomly dialyzed during 3 consecutive periods, each lasting 2 weeks, using a different blood flow rate (Qb) in each period: 400, 300 or 200 ml/min. All HD were prolonged to achieve an on-line dialysate urea monitor (UM) Kt/V of 1.2. The UM Kt/V was compared with the Kt/V calculated using pre-HD, post-HD and rebound (45 min post-HD) plasma water urea concentrations. Comparison of the duration of the second midweek dialysis session with the length of the other HD showed 95% concordance intervals (+/-2 SD) of +/-21.08 min for Qb 400, +/-26.88 min for Qb 300 and +/-37.02 min for Qb 200 ml/min. The 95% concordance intervals for whole body urea clearance were +/-32.0, +/-20.36 and +/-15.62 ml/min for Qb 400, 300 and 200 ml/min, respectively. No differences were observed between UM Kt/V and blood-based double-pool Kt/V obtained by the second-generation Daugirdas (1.18 +/- 0.08) and Garred (1.19 +/- 0.08) Kt/V formulas. In conclusion, a great variability was observed between different HD sessions with regard to the whole body urea clearance and the time required to attain a target Kt/V even when the HD characteristics remained constant. The length of every HD required to achieve a target dose of dialysis can be assessed by on-line dialysate urea. monitoring. Copyright (C) 2001 S. Karger AG, Basel.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [2] On-line monitoring of hemodialysis
    Petitclerc, T
    Perrone, B
    [J]. NEPHROLOGIE, 2003, 24 (02): : 75 - 78
  • [3] A new monitoring system of urea in a waste dialysate for hemodialysis
    Ozaki, M.
    Okabayashi, T.
    Ishimaru, T.
    Hayashi, K.
    Hori, J.
    Nakagawa, M.
    [J]. BLOOD PURIFICATION, 2007, 25 (04) : 347 - 347
  • [4] Monitoring on-line treated water and dialysate quality
    Sobrino Perez, P-E.
    Barril Cuadrado, G.
    del Rey Roman, C.
    Sachez Tomero, J. A.
    [J]. NEFROLOGIA, 2008, 28 (05): : 493 - 504
  • [5] A newly developed on-line monitoring system for the determination of serum electrolytes and urea during hemodialysis
    Yanai, M
    Kihara, K
    Yamada, A
    Takahashi, S
    Sugino, N
    [J]. ARTIFICIAL ORGANS, 1998, 22 (12) : 1010 - 1013
  • [6] Hemodialysis blood access flow rates can be estimated accurately from on-line dialysate urea measurements and the knowledge of effective dialyzer urea clearance
    Lindsay, Robert M.
    Sternby, Jan
    Olde, Bo
    Persson, Roland
    Thatcher, Mary Ellen
    Sargent, Kim
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 1 (05): : 960 - 964
  • [7] Evaluation of pre- and postdilutional on-line hemodiafiltration adequacy by partial dialysate quantification and on-line urea monitor
    Lim, PS
    Lee, HP
    Kho, B
    Yu, YL
    Chang, SC
    Lin, YY
    Yang, CC
    Lin, YT
    Wang, TH
    Kuo, SY
    Lin, LC
    [J]. BLOOD PURIFICATION, 1999, 17 (04) : 199 - 205
  • [8] The on-line urea sensor: A useful method for hemodialysis prescription
    Almirall, J
    Jurkiewicz, M
    Garcia, M
    Sole, S
    Liesa, A
    Padilla, J
    Yuste, E
    Alegret, S
    MartinezFabregas, E
    [J]. NEFROLOGIA, 1996, 16 (06): : 524 - 530
  • [9] IMPACT OF LOW-CALCIUM DIALYSATE ON THE LENGTH OF QT INTERVAL DURING HEMODIALYSIS SESSION
    Eftimovska-Otovic, Natasha
    Spaseska-Gjurovska, Katerina
    Bogdanovska, Sudanka
    Babalj-Banskolieva, Elena
    Milovanceva, Maja
    Grozdanovski, Risto
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 214 - 215
  • [10] A new biosensor for continuous monitoring of the spent dialysate urea level in standard hemodialysis
    Calzavara, P
    Calconi, G
    Da Rin, G
    Canini, E
    Paolini, F
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (03): : 147 - 150