MRI protocol optimization for quantitative DCE-MRI of the spine

被引:5
|
作者
Lavini, Cristina [1 ]
Kramer, Gem [2 ]
Pieters-den Bos, Indra [2 ]
Hoekstra, Otto [2 ]
Marcus, J. T. [2 ]
机构
[1] Acad Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
关键词
Dynamic contrast enhancement; Pharmacokinetic modelling; Tofts' model; Spine; CONTRAST-ENHANCED MRI; VERTEBRAL BONE-MARROW; MULTIPLE-MYELOMA; METASTATIC CANCER; BLOOD PERFUSION; MINERAL DENSITY; CURVE PATTERNS; FAT-CONTENT; PARAMETERS; FRACTURES;
D O I
10.1016/j.mri.2017.08.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this study we systematically investigated different Dynamic Contrast Enhancement (DCE)-MRI protocols in the spine, with the goal of finding an optimal protocol that provides data suitable for quantitative pharmacokinetic modelling (PKM). Materials and methods: In 13 patients referred for MRI of the spine, DCE-MRI of the spine was performed with 2D and 3D MRI protocols on a 3T Philips Ingenuity MR system. A standard bolus of contrast agent (Dotarem 0.2 ml/kg body weight) was injected intravenously at a speed of 3 ml/s. Different techniques for acceleration and motion compensation were tested: parallel imaging, partial-Fourier imaging and flow compensation. The quality of the DCE MRI images was scored on the basis of SNR, motion artefacts due to flow and respiration, signal enhancement, quality of the T-1 map and of the arterial input function, and quality of pharmacokinetic model fitting to the extended Tofts model. Results: Sagittal 3D sequences are to be preferred for PKM of the spine. Acceleration techniques were unsuccessful due to increased flow or motion artefacts. Motion compensating gradients failed to improve the DCE scans due to the longer echo time and the T-2* decay which becomes more dominant and leads to signal loss, especially in the aorta. The quality scoring revealed that the best method was a conventional 3D gradient-echo acquisition without any acceleration or motion compensation technique. The priority in the choice of sequence parameters should be given to reducing echo time and keeping the dynamic temporal resolution below 5 s. Increasing the number of acquisition, when possible, helps towards reducing flow artefacts. In our setting we achieved this with a sagittal 3D slab with 5 slices with a thickness of 4.5 mm and two acquisitions. Conclusion: The proposed DCE protocol, encompassing the spine and the descending aorta, produces a realistic arterial input function and dynamic data suitable for PKM.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [1] Optimization of DCE-MRI protocol for the assessment of patients with brain tumors
    Artzi, Moran
    Liberman, Gilad
    Nadav, Guy
    Blumenthal, Deborah T.
    Bokstein, Felix
    Aizenstein, Orna
    Ben Bashat, Dafna
    [J]. MAGNETIC RESONANCE IMAGING, 2016, 34 (09) : 1242 - 1247
  • [2] Developing a tool for the validation of quantitative DCE-MRI
    Bol, Karin
    Haeck, Joost C.
    Alic, Lejla
    Bernsen, Monique
    de Jong, Marion
    Niessen, Wiro J.
    Veenland, Jifke F.
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [3] Portable perfusion phantom for quantitative DCE-MRI of the abdomen
    Kim, Harrison
    Mousa, Mina
    Schexnailder, Patrick
    Hergenrother, Robert
    Bolding, Mark
    Ntsikoussalabongui, Bernard
    Thomas, Vinoy
    Morgan, Desiree E.
    [J]. MEDICAL PHYSICS, 2017, 44 (10) : 5198 - 5209
  • [4] Applications of DCE-MRI in radiotherapy
    Sourbron, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S2 - S3
  • [5] Integration of DCE-MRI and DW-MRI Quantitative Parameters for Breast Lesion Classification
    Fusco, Roberta
    Sansone, Mario
    Filice, Salvatore
    Granata, Vincenza
    Catalano, Orlando
    Amato, Daniela Maria
    Di Bonito, Maurizio
    D'Aiuto, Massimiliano
    Capasso, Immacolata
    Rinaldo, Massimo
    Petrillo, Antonella
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [6] Validation and implementation of quantitative DCE-MRI imaging for radiation oncology
    Van Zijp, H. M.
    Griffioen, H.
    Philippens, M. E. P.
    Van den Berg, C. A. T.
    Van Tilborg, G.
    Franken, S. P. G.
    De Kruijf, W. J. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S259 - S260
  • [7] A general dual-bolus approach for quantitative DCE-MRI
    Kershaw, Lucy E.
    Cheng, Hai-Ling Margaret
    [J]. MAGNETIC RESONANCE IMAGING, 2011, 29 (02) : 160 - 166
  • [8] Quantitative Hepatic Perfusion Modeling Using DCE-MRI With Sequential Breathholds
    Bultman, Eric M.
    Brodsky, Ethan K.
    Horng, Debra E.
    Irarrazaval, Pablo
    Schelman, William R.
    Block, Walter F.
    Reeder, Scott B.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 853 - 865
  • [9] Investigating the feasibility of performing quantitative DCE-MRI in an abbreviated breast examination
    Slavkova, Kalina P.
    DiCarlo, Julie C.
    Syed, Anum K.
    Wu, Chengyue
    Virostko, John
    Sorace, Anna G.
    Yankeelov, Thomas E.
    [J]. CANCER RESEARCH, 2020, 80 (04)
  • [10] DCE-MRI in experimental chronic pancreatitis
    Shu, Jian
    Zhang, Xiao Ming
    Zhao, Jian Nong
    Yang, Lin
    Zeng, Nan Ling
    Zhai, Zhao Hua
    [J]. CONTRAST MEDIA & MOLECULAR IMAGING, 2009, 4 (03) : 127 - 134