A quick and accurate calibration method for 3D ultrasound in image-guided radiotherapy

被引:1
|
作者
Lachaine, M [1 ]
Audet, V [1 ]
Huang, X [1 ]
Falco, T [1 ]
机构
[1] Resonant Med Inc, Montreal, PQ, Canada
关键词
D O I
10.1118/1.1998629
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a quick, accurate and user‐independent method for calibrating a freehand 3D ultrasound system to CT‐Sim and/or linac room coordinate systems. Method and Materials: A 3D ultrasound system (Restitu, Resonant Medical Inc) designed to be used in both CT‐Sim and radiotherapy treatment rooms is used. This system consists of a 2D ultrasound probe tracked by an optical tracker. An ultrasound phantom was developed which contains six embedded high‐contrast rods at known locations. A removable top‐plate was designed to hold the ultrasound probe in 7 slots with different positions/orientations relative to the rods. The user acquires one image per slot, thus obtaining 7 independent views of the 6 rods. The center of the rods are automatically detected in each ultrasound image. The algorithm calculates the optimal transformation between the detected and known rod positions. In this manner, the calibration from ultrasound image pixels to room laser coordinate system is determined. The transformation is appropriately scaled for different image depths. To evaluate the accuracy, a sphere embedded in the phantom was imaged and reconstructed into a 3D voxel image with the given calibration. The reconstructed center of the sphere was compared to its position derived from a CT scan of the same phantom. Results: The ultrasound calibration procedure is found to be accurate to within the CT sphere center measurement uncertainy. System calibration requires less than 5 minutes. Conclusion: The present calibration method enables a very quick and accurate method of converting a series of 2D ultrasound images into a 3D voxel set in CT‐Sim and/or treatment room coordinate systems. This forms the basis for accurate 3D ultrasound imaging in radiotherapy, both for improved organ definition for planning and image guidance in the treatment room. Conflict of Interest: The authors are employees of Resonant Medical Inc. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2154 / 2155
页数:2
相关论文
共 50 条
  • [1] A fast and accurate method of ultrasound probe calibration for image-guided surgery
    Welch, JN
    Bax, M
    Mori, K
    Krummel, T
    Shahidi, R
    Maurer, CR
    [J]. CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1078 - 1078
  • [2] NOVEL 3D ULTRASOUND IMAGING TECHNIQUES FOR IMAGE-GUIDED PROSTATE RADIOTHERAPY
    Verhaegen, F.
    Fraser, D.
    Chen, Y.
    Koptenko, S.
    Falco, T.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S32 - S33
  • [3] 3D Ultrasound Imaging in Image-Guided Intervention
    Fenster, Aaron
    Bax, Jeff
    Neshat, Hamid
    Cool, Derek
    Kakani, Nirmal
    Romagnoli, Cesare
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6151 - 6154
  • [4] Accurate calibration of a stereo-vision system in image-guided radiotherapy
    Liu, Dezhi
    Li, Shidong
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4379 - 4383
  • [5] Evaluation of inter-fractional prostate motion using 3D ultrasound image-guided radiotherapy
    Martyn, M.
    Moore, M.
    Kleefeld, C.
    Foley, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S241 - S242
  • [6] Integration of 3D stereovision system in image-guided radiotherapy: A DICOM-based method
    Liu, D.
    Li, S.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2039 - 2039
  • [7] 3D Spatial Compounding Using the Clarity System Improves Ultrasound Image Quality in Gynecological Image-Guided Radiotherapy
    Mason, S.
    O'Shea, T.
    White, I.
    McNair, H.
    Blackledge, M.
    Laldondrelle, S.
    Bamber, J.
    Harris, E.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3069 - 3069
  • [8] 3D ultrasound imaging: applications in image-guided therapy and biopsy
    Fenster, A
    Surry, K
    Smith, W
    Gill, J
    Downey, DB
    [J]. COMPUTERS & GRAPHICS-UK, 2002, 26 (04): : 557 - 568
  • [9] 3D Surface Image-Guided
    Tang, X.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3816 - 3817
  • [10] 4D MR Reconstruction Based on Real-Time 3D Ultrasound for Image-Guided Radiotherapy
    Jupitz, S.
    Holmes, J.
    Bednarz, B.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)