MIND Demons: Symmetric Diffeomorphic Deformable Registration of MR and CT for Image-Guided Spine Surgery

被引:42
|
作者
Reaungamornrat, Sureerat [1 ]
De Silva, Tharindu [2 ]
Uneri, Ali [1 ]
Vogt, Sebastian [3 ]
Kleinszig, Gerhard [3 ]
Khanna, Akhil J. [4 ]
Wolinsky, Jean-Paul [5 ]
Prince, Jerry L. [6 ]
Siewerdsen, Jeffrey H. [2 ]
机构
[1] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[3] Siemens Healthcare XP, D-91052 Erlangen, Germany
[4] Johns Hopkins Orthopaed Surg, Dept Orthopaed Surg, Bethesda, MD USA
[5] Johns Hopkins Univ Hosp, Dept Neurosurg, Baltimore, MD 21205 USA
[6] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
关键词
deformable image registration; Demons algorithm; symmetric diffeomorphism; multimodality image registration; MIND; CT; MRI; image-guided surgery; NONRIGID REGISTRATION; MUTUAL INFORMATION; NAVIGATION; ALGORITHM;
D O I
10.1109/TMI.2016.2576360
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Intraoperative localization of target anatomy and critical structures defined in preoperative MR/CT images can be achieved through the use of multimodality deformable registration. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality-independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. The method, called MIND Demons, finds a deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the integrated velocity fields, a modality-insensitive similarity function suitable to multimodality images, and smoothness on the diffeomorphisms themselves. Direct optimization without relying on the exponential map and stationary velocity field approximation used in conventional diffeomorphic Demons is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, normalized MI (NMI) Demons, and MIND with a diffusion-based registration method (MIND-elastic). The method yielded sub-voxel invertibility (0.008 mm) and nonzero-positive Jacobian determinants. It also showed improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.7 mm compared to 11.3, 3.1, 5.6, and 2.4 mm for MI FFD, LMI FFD, NMI Demons, and MIND-elastic methods, respectively. Validation in clinical studies demonstrated realistic deformations with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine.
引用
收藏
页码:2413 / 2424
页数:12
相关论文
共 50 条
  • [1] MIND Demons for MR-to-CT Deformable Image Registration In Image-Guided Spine Surgery
    Reaungamornrat, S.
    De Silva, T.
    Uneri, A.
    Wolinsky, J. -P.
    Khanna, A. J.
    Kleinszig, G.
    Vogt, S.
    Prince, J. L.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [2] Clinical Application of the MIND Demons Algorithm for Symmetric Diffeomorphic Deformable MR-To-CT Image Registration in Spinal Interventions
    Reaungamornrat, S.
    De Silva, T.
    Uneri, A.
    Wolinsky, J.
    Khanna, A.
    Kleinszig, G.
    Vogt, S.
    Prince, J.
    Siewerdsen, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3885 - 3885
  • [3] Validation of an Improved 'Diffeomorphic Demons' Algorithm for Deformable Image Registration in Image-Guided Radiation Therapy
    Zhou, Lu
    Zhou, Linghong
    Zhang, Shuxu
    Zhen, Xin
    Yu, Hui
    Zhang, Guoqian
    Wang, Ruihao
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 373 - 382
  • [4] A momentum-based diffeomorphic demons framework for deformable MR-CT image registration
    Han, R.
    De Silva, T.
    Ketcha, M.
    Uneri, A.
    Siewerdsen, J. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (21):
  • [5] Registration of CT and MR images for navigation in image-guided brain surgery
    Hosten, N
    Rohlfing, T
    Beier, J
    Liebig, T
    Lanksch, W
    Felix, R
    [J]. RADIOLOGY, 1998, 209P : 206 - 206
  • [6] Performance evaluation of MIND demons deformable registration of MR and CT images in spinal interventions
    Reaungamornrat, S.
    De Silva, T.
    Uneri, A.
    Goerres, J.
    Jacobson, M.
    Ketcha, M.
    Vogt, S.
    Kleinszig, G.
    Khanna, A. J.
    Wolinsky, J-P
    Prince, J. L.
    Siewerdsen, J. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23): : 8276 - 8297
  • [7] Automatic Deformable MR-Ultrasound Registration for Image-Guided Neurosurgery
    Rivaz, Hassan
    Chen, Sean Jy-Shyang
    Collins, D. Louis
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 366 - 380
  • [8] Evaluation of Diffeomorphic Demons Algorithm for Deformable Image Registration Using Virtual Phantom
    Reiazi, R.
    Mohammadi, R.
    Mahdavi, S. R.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [9] Deformable registration for image-guided radiation therapy
    Sarrut, David
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (04): : 285 - 297
  • [10] Surface-based registration accuracy of CT-based image-guided spine surgery
    Tamura, Y
    Sugano, N
    Sasama, T
    Sato, Y
    Tamura, S
    Yonenobu, K
    Yoshikawa, H
    Ochi, T
    [J]. EUROPEAN SPINE JOURNAL, 2005, 14 (03) : 291 - 297