Spectrofluorimetric determination of bilirubin in serum samples

被引:12
|
作者
Bian, Weiwei [2 ]
Zhang, Na [3 ]
Jiang, Chongqiu [1 ]
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Jinan 250014, Peoples R China
[2] Weifang Med Univ, Weifang, Shandong, Peoples R China
[3] Huangshan Coll, Dept Chem, Huangshan 245041, Peoples R China
关键词
spectrofluorimetry; bilirubin; oxytetracycline; europium ion; QUANTITATIVE-DETERMINATION; CAPILLARY-ELECTROPHORESIS; DIAZO METHOD; ALBUMIN; CHEMILUMINESCENCE; OXIDASE;
D O I
10.1002/bio.1185
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new spectrofluorimetric method was developed for determination of trace amount of bilirubin. Using oxytetracycline-Eu3+ as a fluorescent probe, in the buff er solution of pH = 7.3, bilirubin can reduce remarkably the fluorescence intensity of the oxytetracycline-Eu3+ complex at lambda = 612 nm and the reduced fluorescence intensity was in proportion to the concentration of bilirubin. Optimum conditions for the determination of bilirubin were also investigated. The linear range and limit of detection for the determination of bilirubin were 5.0 x 10 (7), 3.0 x 10 (5) and 7.7 x 10 (8) mol L (1), respectively. This method is simple, practical and relatively free of interference from coexisting substances and can be successfully applied to assess bilirubin in serum samples and compared with the modified Jendrassik-Grof method in clinical analysis. The quenching mechanism of the fluorescence intensity in the system is also discussed. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:54 / 58
页数:5
相关论文
共 50 条
  • [1] Spectrofluorimetric quantification of bilirubin using yttrium-norfloxacin complex as a fluorescence probe in serum samples
    Kamruzzaman, Mohammad
    Alam, Al-Mahmnur
    Lee, Sang Hak
    Kim, Young Ho
    Kim, Gyu-Man
    Oh, Sang Hyub
    JOURNAL OF LUMINESCENCE, 2012, 132 (11) : 3053 - 3057
  • [2] Spectrofluorimetric determination of lecithin in serum samples using enoxacine-terbium probe
    Bian, Weiwei
    Li, Jing
    Jiang, Chongqiu
    ANALYTICAL LETTERS, 2007, 40 (06) : 1037 - 1045
  • [3] Spectrofluorimetric determination of arsenic in water samples
    Pal, A
    Jana, NR
    Sau, TK
    Bandyopadhyay, M
    Pal, T
    ANALYTICAL COMMUNICATIONS, 1996, 33 (09): : 315 - 317
  • [4] Spectrofluorimetric determination of formaldehyde in liquid samples
    de Andrade, JB
    Bispo, MS
    Reboucas, MV
    Carvalho, MLSM
    Pinheiro, HLC
    AMERICAN LABORATORY, 1996, 28 (12) : 56 - +
  • [5] Spectrofluorimetric determination of bilirubin using enoxacine-terbium probe
    Bian, Weiwei
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 421 - 424
  • [6] Spectrofluorimetric Determination of Arsenic(III) in Water Samples
    Zhu, R. H.
    Chen, L. H.
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (12) : 5271 - 5274
  • [7] Serum bilirubin measurements in hemolyzed samples
    McDonagh, Antony F.
    Lo, Stanley F.
    Maisels, M. Jeffrey
    Watchko, Jon F.
    CLINICA CHIMICA ACTA, 2011, 412 (13-14) : 1275 - 1275
  • [8] AUTOMATED DETERMINATION OF SERUM BILIRUBIN
    BARTELS, H
    BOHMER, M
    ZEITSCHRIFT FUR KLINISCHE CHEMIE UND KLINISCHE BIOCHEMIE, 1971, 9 (02): : 133 - &
  • [9] PROPERTIES AND DETERMINATION OF SERUM BILIRUBIN
    DEFREESE, JD
    WANG, TSC
    CRC CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 1984, 19 (04): : 267 - 296
  • [10] PHOTOELECTRIC DETERMINATION OF SERUM BILIRUBIN
    WHIDBORNE, J
    GRAY, CH
    BIOCHEMICAL JOURNAL, 1945, 39 (05) : R11 - R12