Numerical assessment on the performance of variable area single- and two-stage ejectors: A comparative study

被引:4
|
作者
Kumar, Anil [1 ]
Kumar, Virendra [1 ]
Subbarao, P. M., V [2 ]
Yadav, Surendra K. [3 ]
Singhal, Gaurav [4 ]
机构
[1] Kamla Nehru Inst Technol, Dept Mech Engn, Sultanpur 228118, Uttar Pradesh, India
[2] Indian Inst Technol, Dept Mech Engn, Mumbai, Maharashtra, India
[3] KR Mangalam Univ, Dept Mech Engn, Gurgaon, India
[4] Laser Sci & Technol Ctr, Metcalfe House, Delhi, India
关键词
Computational fluid dynamics; constant rate of momentum change; ejector; entrainment ratio; two stage; CFD SIMULATION; CONSTANT RATE; MIXING SECTION; STEAM EJECTOR; FLOW;
D O I
10.1177/09544089211033129
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The two-stage ejector has been suggested to replace the single-stage ejector geometrical configuration better to utilize the discharge flow's redundant momentum to induce secondary flow. In this study, the one-dimensional gas dynamic constant rate of momentum change theory has been utilized to model a two-stage ejector along with a single-stage ejector. The proposed theory has been utilized in the computation of geometry and flow parameters of both the ejectors. The commercial computational fluid dynamics tool ANSYS-Fluent 14.0 has been utilized to predict performance and visualize the flow. The performance in terms of entrainment ratio has been compared under on- design and off-design conditions. The result shows that the two-stage ejector configuration has improved (approximate to 57%) entrainment capacity than the single-stage ejector under the on-design condition.
引用
收藏
页码:114 / 125
页数:12
相关论文
共 50 条
  • [1] Single- or two-stage compression
    Jekel, Todd B.
    Reindl, Douglas T.
    [J]. ASHRAE JOURNAL, 2008, 50 (08) : 46 - +
  • [2] Comparative study of single- and two-stage fermentation of the brown seaweed Laminaria digitata
    Guneratnam, Amita Jacob
    Xia, Ao
    Murphy, Jerry D.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 405 - 412
  • [3] Comparative study on energy-saving performance of single- and two-stage evaporative-cooling condenser systems
    Yang, Yang
    Zeng, Jun
    Yang, Boyu
    Yin, Linmao
    He, Tianyou
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 160 : 390 - 401
  • [4] Comparative Study of Single Stage and Two-Stage Pretreatments on Corn Stover: A Kinetic Assessment
    Liu, Chao
    Zhang, Rui
    Yu, Jingjie
    Chang, Jing
    Zhang, Wenjuan
    [J]. BIORESOURCES, 2022, 17 (01) : 1257 - 1269
  • [5] Comparison of the optimal performance of single- and two-stage thermoelectric refrigeration systems
    Chen, JC
    Zhou, YH
    Wang, HJ
    Wang, JT
    [J]. APPLIED ENERGY, 2002, 73 (3-4) : 285 - 298
  • [6] Influence of Single- and Two-Stage Aggregate Manufacturing Mechanisms on Asphalt Mixture Performance
    Hafeez, I.
    Juniad, F.
    Kamal, M. A.
    Hussain, J.
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2016, 28 (04)
  • [7] Comparative thermodynamic performance assessment of two-stage cycle for various refrigerants
    Yilmaz, Fatih
    Ozturk, Murat
    Selbas, Resat
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2019, 29 (2-4) : 110 - 130
  • [8] Numerical Simulation of Two-Stage Variable Geometry Turbine
    Kozak, Dariusz
    Mazuro, Pawel
    Teodorczyk, Andrzej
    [J]. ENERGIES, 2021, 14 (17)
  • [9] Of stones and bile ducts, single- vs two-stage management
    Cuschieri, A
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1996, 10 (12): : 1124 - 1124
  • [10] Performance of a new two-stage transcritical CO2 refrigeration cycle with two ejectors
    Manjili, F. Eskandari
    Cheraghi, M.