Preparation and in vitro degradation of the composite coating with high adhesion strength on biodegradable Mg-Zn-Ca alloy

被引:44
|
作者
Li, Wen [1 ]
Guan, Shaokang [1 ]
Chen, Juan [2 ]
Hu, Junhua [1 ]
Chen, Shuai [1 ]
Wang, Liguo [1 ]
Zhu, Shijie [1 ]
机构
[1] Zhengzhou Univ, Sch Mat Sci & Engn, Zhengzhou 450002, Peoples R China
[2] Osaka Univ, Div Mat & Mfg Sci, Osaka 5670047, Japan
基金
中国国家自然科学基金;
关键词
Composite coating; Mg-Zn-Ca alloy; Degradation property; Compressive load; DEPOSITED HYDROXYAPATITE COATINGS; CORROSION-RESISTANCE BEHAVIOR; VIVO CORROSION; OCTACALCIUM PHOSPHATE; MECHANICAL INTEGRITY; MAGNESIUM ALLOYS; NITI ALLOY; ELECTRODEPOSITION; OXIDATION; FILMS;
D O I
10.1016/j.matchar.2011.07.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Biodegradable magnesium alloys are potential for bone implants. In order to improve the corrosion resistance and the surface bioactivity of Mg-Zn-Ca alloy, a composite coating which had high adhesion strength with the substrate was prepared on Mg-Zn-Ca alloy through combined micro-arc oxidation and electrochemical deposition. The composite coating had needle-like structure and consisted of MgO, Mg-3(PO4)(2), hydroxyapatite and octacalcium phosphate. The thickness of the composite coating was about 12-15 mu m and the adhesion strength of the optimum composite coating with the substrate was higher than 40 MPa. The potentiodynamic polarization and hydrogen evolution tests in simulated body fluid indicated that the composite coating significantly improved the corrosion resistance of the substrate. Deposition of Ca/P salt on the composite coating showed good surface bioactivity of the composite coating in hydrogen evolution tests. The compression tests of the composite coating modified alloy immersed in simulated body fluid for different time revealed that it could meet requirement of bone implant materials in the initial bone reunion period. Thus, the surface modification of the composite coating greatly enhanced the potential of magnesium and its alloy as degradable implants. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:1158 / 1165
页数:8
相关论文
共 50 条
  • [1] In-vitro Evaluation of Degradation of Biodegradable Silane Based Coating on Mg-Zn-Ca Alloy in a Physiological Environment
    Gaur, Swati
    Khanna, A. S.
    Raman, R. K. Singh
    [J]. LIGHT METALS TECHNOLOGY 2013, 2013, 765 : 803 - +
  • [2] In Vitro Evaluation of Degradation of a Calcium Phosphate Coating on a Mg-Zn-Ca Alloy in a Physiological Environment
    Choudhary, L.
    Raman, R. K. Singh
    Nie, J. F.
    [J]. CORROSION, 2012, 68 (06) : 499 - 506
  • [3] Mechanical Integrity and In vitro Degradation Behavior of Mg-Zn-Ca Biodegradable Alloy Prepared by Different Casting Technologies
    Moussa, M. E.
    Salem, Mahmoud M. M.
    Hamid, Maamoun Abdel
    Gomaa, Mona H.
    Abd-Elwahed, Ahmed
    Ghayad, Ibrahim M.
    Mohamed, Adel A.
    [J]. INTERNATIONAL JOURNAL OF METALCASTING, 2023,
  • [4] In vivo degradation and bone response of a composite coating on Mg-Zn-Ca alloy prepared by microarc oxidation and electrochemical deposition
    Chen, Shuai
    Guan, Shaokang
    Li, Wen
    Wang, Huanxin
    Chen, Juan
    Wang, Yisheng
    Wang, Haitao
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (02) : 533 - 543
  • [5] Mechanical and Biological Properties of a Biodegradable Mg-Zn-Ca Porous Alloy
    Zhang, Yong-qiang
    Li, Yang
    Liu, Huan
    Bai, Jing
    Bao, Ni-rong
    Zhang, Yue
    He, Peng
    Zhao, Jian-ning
    Tao, Li
    Xue, Feng
    Zhou, Guang-xin
    Fan, Gen-tao
    [J]. ORTHOPAEDIC SURGERY, 2018, 10 (02) : 160 - 168
  • [6] Preparation and characterization of a new biomedical Mg-Zn-Ca alloy
    Sun, Yu
    Zhang, Baoping
    Wang, Yin
    Geng, Lin
    Jiao, Xiaohui
    [J]. MATERIALS & DESIGN, 2012, 34 : 58 - 64
  • [7] Electrochemical property and in vitro degradation of DCPD-PCL composite coating on the biodegradable Mg-Zn alloy
    Wang, Hongju
    Zhao, Changli
    Chen, Ying
    Li, Jianan
    Zhang, Xiaonong
    [J]. MATERIALS LETTERS, 2012, 68 : 435 - 438
  • [8] Degradation of biodegradable implants: The influence of microstructure and composition of Mg-Zn-Ca alloys
    Roche, V
    Koga, G. Y.
    Matias, T. B.
    Kiminami, C. S.
    Bolfarini, C.
    Botta, W. J.
    Nogueira, R. P.
    Jorge Junior, A. M.
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2019, 774 : 168 - 181
  • [9] Mechanical properties and controlling degradation rate of Mg-Zn-Ca alloy
    Zhang, Ya-Jing
    Zuo, Li-Jing
    Xing, Xiao-Le
    Wang, Fan
    [J]. Dongbei Daxue Xuebao/Journal of Northeastern University, 2013, 34 (07): : 935 - 938
  • [10] In-vitro Degradation and Cytocompatibility Assessment of Mg-Zn and Mg-Zn-Ca Alloys
    Gill, Puneet
    Munroe, Norman
    Dua, Rupak
    Ramaswamy, Sharan
    [J]. MEDICAL DEVICE MATERIALS VI, 2013, : 104 - 107