Determination of sialic acids in infant formula by liquid chromatography tandem mass spectrometry

被引:8
|
作者
Sorensen, L. K. [1 ]
机构
[1] Eurofins Steins Lab, DK-7500 Holstebro, Denmark
关键词
LC-MS/MS; infant formula; sialic acids; N-acetylneuraminic acid; N-glycolylneuraminic acid; ANION-EXCHANGE CHROMATOGRAPHY; PULSED AMPEROMETRIC DETECTION; HUMAN-MILK OLIGOSACCHARIDES; ASSAY;
D O I
10.1002/bmc.1429
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatographic/tandem mass spectrometric method using pneumatically assisted electrospray ionization (LC-ESI-MS/MS) was developed for determination of N-acetylneuramic acid and N-glycolylneuramic acid in infant formula Reconstituted samples were hydrolysed in dilute sulfuric acid and deproteinized with acetonitrile The extract was analysed directly without further clean-up by hydrophilic interaction chromatography The substances were detected in negative ion mode and matrix matched standards were used for calibration The relative intra-laboratory reproducibility standard deviation was better than 6% for both substances An R(2) of 0 985 was obtained by comparison with a classical colorimetric assay based on reaction with resorcinol The developed method is expected to be applied for accurate routine analysis of infant formulas Copyright (C) 2010 John Wiley & Sons, Ltd
引用
收藏
页码:1208 / 1212
页数:5
相关论文
共 50 条
  • [1] Determination of sialic acids by liquid chromatography-mass spectrometry
    Shaw, CJ
    Chao, H
    Xiao, BM
    JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) : 365 - 370
  • [2] Analysis of nucleosides and nucleotides in infant formula by liquid chromatography–tandem mass spectrometry
    Brendon D. Gill
    Harvey E. Indyk
    Merilyn Manley-Harris
    Analytical and Bioanalytical Chemistry, 2013, 405 : 5311 - 5319
  • [3] Determination of acrylamide in infant formula milk powder by ultraperformance liquid chromatography-tandem mass spectrometry
    Li, Ying Crystal
    Zhao, Tieying
    He, Qiang
    Li, Zihao
    Chinese Journal of Analysis Laboratory, 2023, 42 (06) : 796 - 799
  • [4] Quick determination of 39 hormones residues in infant formula by liquid chromatography-tandem mass spectrometry
    Zhu Weixia
    Liu Yafeng
    Yuan Ping
    Yang Jizhou
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (11) : 1031 - 1037
  • [5] Determination of proteins in infant formula by high-performance liquid chromatography-electrospray tandem mass spectrometry
    Hong, Soon Sun
    Park, Jeong Hill
    Kwon, Sung Won
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01): : 69 - 73
  • [6] Determination of Casein Allergens in Extensively Hydrolyzed Casein Infant Formula by Liquid Chromatography-Tandem Mass Spectrometry
    Hostetler, Gregory L.
    Barber, Cynthia M.
    Miklus, Michael B.
    Prieto, Pedro A.
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (01) : 172 - 179
  • [7] Improvement of accuracy for the determination of vitamin A in infant formula by isotope dilution-liquid chromatography/tandem mass spectrometry
    Lim, Young Ok
    Kim, Byungjoo
    Ahn, Seonghee
    Kim, Jeongkwon
    FOOD CHEMISTRY, 2011, 126 (03) : 1393 - 1398
  • [8] Determination of Fructooligosaccharides in Infant Formula by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Li, Wei
    Jiang, Dafeng
    Chen, Jindong
    Sun, Qihua
    Li, Fenghua
    Jiao, Yanni
    Qu, Fei
    ANALYTICAL LETTERS, 2014, 47 (06) : 934 - 943
  • [9] Determination of dicyandiamide in infant formula by stable isotope dilution hydrophilic interaction liquid chromatography with tandem mass spectrometry
    Inoue, Koichi
    Sakamoto, Tasuku
    Min, Jun Zhe
    Todoroki, Kenichiro
    Toyo'oka, Toshimasa
    FOOD CHEMISTRY, 2014, 156 : 390 - 393
  • [10] Analysis of nucleosides and nucleotides in infant formula by liquid chromatography-tandem mass spectrometry
    Gill, Brendon D.
    Indyk, Harvey E.
    Manley-Harris, Merilyn