Imaging Tumor Motion using 4D-MRI

被引:1
|
作者
Cai, J. [1 ]
Chang, Z. [1 ]
Yin, F. [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC USA
关键词
D O I
10.1016/j.ijrobp.2011.06.251
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S122 / S123
页数:2
相关论文
共 50 条
  • [1] 4D-MRI Analysis of Pancreatic Tumor Motion
    Rochet, N.
    Timke, C.
    Roeder, F.
    Thieke, C.
    Pruem, H.
    Floca, R.
    Schlemmer, H. P.
    Debus, J.
    Huber, P.
    Dinkel, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S343 - S343
  • [2] 4D-MRI analysis of lung tumor motion in patients with hemidiaphragmatic paralysis
    Dinkel, Julien
    Hintze, Christian
    Tetzlaff, Ralf
    Huber, Peter E.
    Herfarth, Klaus
    Debus, Juergen
    Kauczor, Hans U.
    Thieke, Christian
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) : 449 - 454
  • [3] 4D treatment planning using motion information from 4D-MRI
    Boye, D.
    Lomax, T.
    Knopf, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 732 - 732
  • [4] Assessment of 4D-MRI for Robust Motion and Volume Characterization
    Glide-Hurst, C.
    Kim, J.
    Hu, Y.
    Wen, N.
    Mutic, S.
    Chetty, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 539 - 539
  • [5] Better motion-compensated daily imaging using 4D-MRI for MR-linac gating workflows
    Keijnemans, Katrinus
    Schakel, Tim
    Borman, Pim T. S.
    Raaymakers, Bas W.
    Paulson, Eric S.
    Fast, Martin F.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4237 - S4240
  • [6] Evaluation of outlier rejection in 4D-MRI for motion estimation of subsequent sessions
    Den Boer, D.
    Veldman, J.
    Bel, A.
    Van Kesteren, Z.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S953 - S954
  • [7] Identifying Abdominal Inter-Organ Motion Correlations Using 4D-MRI and 4D-Image Registration
    Yue, Y.
    Fan, Z.
    Deng, Z.
    Pang, J.
    DeMarco, J.
    Tuli, R.
    Li, D.
    Fraass, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3539 - 3539
  • [8] Evaluation of COPD's Diaphragm Motion Extracted from 4D-MRI
    Swastika, Windra
    Masuda, Yoshitada
    Kawata, Naoko
    Matsumoto, Koji
    Suzuki, Toshio
    Iesato, Ken
    Tada, Yuji
    Sugiura, Toshihiko
    Tanabe, Nobuhiro
    Tatsumi, Koichiro
    Ohnishi, Takashi
    Haneishi, Hideaki
    MEDICAL IMAGING 2015: IMAGE PROCESSING, 2015, 9413
  • [9] Verification of 4D-MRI Internal Target Volume Using Cine MRI
    Lafata, K.
    Czito, B.
    Palta, M.
    Bashir, M.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 201 - 201
  • [10] A hybrid 2D/4D-MRI methodology using simultaneous multislice imaging for radiotherapy guidance
    Keijnemans, Katrinus
    Borman, Pim T. S.
    Uijtewaal, Prescilla
    Woodhead, Peter L.
    Raaymakers, Bas W.
    Fast, Martin F.
    MEDICAL PHYSICS, 2022, 49 (09) : 6068 - 6081